H5AN-4D AC100-240 OMRON Time Relay NEW

OMRON Time Relay H5AN-4D AC100-240                     

Product Description:

Wide time range from 1/100 seconds to 9999 hrs.

Built-in power supply incorporated in timer enables direct connection of sensors and other components.

Draw-out construction allows maintenance without disconnecting the wiring.

Power supply freely selectable within a range of 100 to 240 VAC; a DC-operated version is also available.

Control outputs of both contact type and solid-state type simultaneously available.

Seven operating modes (N, F, C, R, K, P, and Q) are available.

Specifications:

Ratings

Item

H5AN-4D/H5AN-4DM

Rated supply voltage

H5AN-4D: 100 to 240 VAC (50/60 Hz),

12 to 24, 48, or 100 VDC (permissible ripple: 20% max.)

H5AN-4DM: 100 to 240 VAC (50/60 Hz)

12 to 24 VDC (permissible ripple: 20% max.)

Operating voltage range

85% to 110% of rated supply voltage

Power consumption

Approx. 10 VA (at 240 VAC, 50 Hz), approx. 5 W (at 24 VDC)

Resetting system and gate input

Reset by power-OFF: min. power OFF time: 0.5 s

External reset or gate (common to contact and solid-state inputs): min. reset input signal width: 0.02 s

One-shot output time

0.1 to 1 s (adjustable)

Control outputs

Contact output: SPDT, 3 A at 250 VAC, resistive load (cosΦ = 1)

Solid-state output: Open collector, 100 mA max. at 30 VDC max.

Power supply for externally connected components

12 VDC±10%, 80 mA (permissible ripple: 5% max.)

Note: Inrush current was measured within the range shown below.

Characteristics

 

Accuracy of operating time

±0.01% ±0.05 s max. (power OFF start), ±0.005% ±0.03 s max. (reset start) (see note)

Setting error

Influence of voltage

Influence of temperature

Insulation resistance

100 MΩ min. (at 500 VDC) (between current-carrying terminal and exposed non-current carrying metal

parts, between non-continuous contacts)

Dielectric strength

2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying metal parts)

750 VAC, 50/60 Hz for 1 min (between non-continuous contacts)

Vibration resistance

Destruction: 10 to 55 Hz with 0.75-mm double amplitude

Malfunction: 10 to 55 Hz with 0.5-mm double amplitude

Shock resistance

Destruction: 300 m/s2 (approx. 30G)

Malfunction: 100 m/s2 (approx. 10G)

Ambient temperature

Operating: -10°C to 55°C

Storage: -25°C to 65°C

Ambient humidity

Operating: 35% to 85%

Life expectancy

Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)

Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load)

Approved standards

UL (File No. E41515), CSA (File No. LR22310)

Weight

Approx. 360 g

Note: This value denotes the average of the repeat accuracy, setting error, and variations due to voltage and temperature changes. It includes the rise time of the power supply, and the operating time of the internal and output circuits.

 

  