Your Position: Home > Low Voltage > Relay > H3YN-4 DC24V Time Relay NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

H3YN-4 DC24V Time Relay NEW

prevnext

H3YN-4 DC24V Time Relay NEW
  • Market price: $ 171.6
  • Shop price: $ 52.0
  • Goods click count: 331
  • Total:
  • Quantity:
Add to cart collect
  

Description

H3YN-4 DC24V OMRON Time Relay NEW

OMRON Time Relay H3YN-4 DC24V                      

Product Description:

Minimizes stock.

Pin configuration compatible with MY Power Relay.

Standard multiple operating modes and multiple time ranges.

Conforms to EN61812-1 and IEC60664-1 for Low Voltage, and EMC Directives.

Specifications:

Ratings

Item

H3YN-2/-4/-4-Z

H3YN-21/-41/-41-Z

Time ranges

0.1 s to 10 min (1 s, 10 s, 1 min,

0.1 min to 10 h (1 min, 10 min, 1 h, or

or 10 min max. selectable)

10 h max. selectable)

Rated supply voltage

24, 100 to 120, 200 to 230 VAC (50/60 Hz) (See note 1.)

12, 24, 48, 100 to 110, 125 VDC (See note 2.)

Pin type

Plug-in

Operating mode

ON-delay, interval, flicker OFF start, or flicker ON start (selectable with DIP switch)

Operating voltage range

85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage) (See note 3.)

Reset voltage

10% min. of rated supply voltage (See note 4.)

Power consumption

100 to 120 VAC:

Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz

Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz

200 to 230 VAC:

Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz

Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz

24 VAC:

Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz

Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz

12 VDC:

Relay ON: Approx. 1.1 W at 12 VDC

Relay OFF: Approx. 0.1 W at 12 VDC

24 VDC:

Relay ON: Approx. 1.1 W at 24 VDC

Relay OFF: Approx. 0.1 W at 24 VDC

48 VDC:

Relay ON: Approx. 1.2 W at 48 VDC

Relay OFF: Approx. 0.3 W at 48 VDC

100 to 110 VDC:

Relay ON: Approx. 1.6 W at 110 VDC

Relay OFF: Approx. 0.4 W at 110 VDC

125 VDC:

Relay ON: Approx. 1.6 W at 125 VDC

Relay OFF: Approx. 0.4 W at 125 VDC

Control outputs

DPDT: 5 A at 250 VAC, resistive load (cosΦ = 1)

4PDT: 3 A at 250 VAC, resistive load (cosΦ = 1)

Note:

1.Do not use the output from an inverter as the power supply.

2.Single-phase, full-wave-rectified power supplies can be used.

3.When using the H3YN continuously in any place where the ambient temperature is in a range of 45°C to 50°C, supply 90% to 110% of the rated supply voltages (supply 95% to 110% with 12 VDC type).

4.Set the reset voltage as follows to ensure proper resetting.

100 to 120 VAC: 10 VAC max.

200 to 230 VAC: 20 VAC max.

100 to 110 VDC: 10 VDC max.

Characteristics

 

Item

H3YN-2/-21/-4/-41

Accuracy of

±1% FS max. (1 s range: ±1%±10 ms max.)

operating time

Setting error

±10%±50 ms FS max.

Reset time

Min. power-opening time: 0.1 s max. (including halfway reset)

Influence of voltage

±2% FS max.

Influence of temperature

±2% FS max.

Insulation resistance

100 MΩ min. (at 500 VDC)

Dielectric strength

2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts) (see note 1)

2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output)

2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model)

1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)

1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)

Vibration resistance

Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 1 h each in 3 directions

Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in 3 directions

Shock resistance

Destruction: 1,000 m/s2

Malfunction: 100 m/s2

Ambient temperature

Operating: - 10°C to 50°C (with no icing)

Storage: - 25°C to 65°C (with no icing)

Ambient humidity

Operating: 35% to 85%

Life expectancy

Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)

Electrical: DPDT:

500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)

4PDT:

200,000 operations min. (H3YN-4-Z/-41-Z: 100,000 operations min.)

(3 A at 250 VAC, resistive load at 1,800 operations/h)

Impulse withstand

Between power terminals:

voltage

3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC

 

1 kV for 12 VDC, 24 VDC, 48 VDC, 24 VAC

 

Between exposed non-current-carrying metal parts:

 

4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC

 

1.5 kV for 12 VDC, 24 VDC, 48 VDC, 24 VAC

Noise immunity

±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)

Static immunity

Destruction: 8 kV

Malfunction: 4 kV

Degree of protection

IP40

Weight

Approx. 50 g

EMC

(EMI) EN61812-1

Emission Enclosure: EN55011 Group 1 class A

Emission AC Mains: EN55011 Group 1 class A

(EMS) EN61812-1

Immunity ESD: EN61000-4-2: 8 kV air discharge (level 3)

Immunity RF-interference from AM Radio Waves:

EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)

Immunity Burst: EN61000-4-4: 2 kV power-line (level 3)

2 kV I/O signal-line (level 4)

Immunity Surge: EN61000-4-5: 2 kV line to ground (level 3)

1 kV line to line (level 3)

Approved standards

UL508, CSA C22.2 No. 14, Lloyds

Conforms to EN61812-1 and IEC60664-1. (2.5 kV/2 for H3YN-2/-21, 2.5 kV/1 for H3YN-4/-41, H3YN-4-Z/-41-Z)

Output category according to EN60947-5-1.

Note:Terminal screw sections are excluded.

 

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: