Your Position: Home > Low Voltage > Relay > G9SA-301 AC/DC24V Relay NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

G9SA-301 AC/DC24V Relay NEW

prevnext

G9SA-301 AC/DC24V Relay NEW
  • Market price: $ 663.3
  • Shop price: $ 201.0
  • Goods click count: 407
  • Total:
  • Quantity:
Add to cart collect
  

Description

G9SA-301 OMRON RELAY New

Product Description?

Four kinds of 45-mm wide Units are available:
A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a Two-hand Controller.
Also available are 17.5-mm wide Expansion Units with 3 poles and 3 OFF-delay poles.

Simple expansion connection.

OFF-delay models have 15-step OFF-delay settings.

Conforms to EN ISO13849-1 (Cat.4/PLe).

Both DIN track mounting and screw mounting are possible.

Specifications:

Model

G9SA-301/TH301

G9SA-501

G9SA-321-T[]

 

Power supply
voltage

24 VAC/VDC: 24 VAC, 50/60 Hz, or 24 VDC
100 to 240 VAC: 100 to 240 VAC, 50/60 Hz

 
 

Operating
voltage range

85% to 110% of rated power supply voltage

 

Power
consumption*

24 VAC/VDC: 1.8 VA/1.7 W max.
100 to 240 VAC: 9 VA max.

24 VAC/VDC: 2.8 VA/2.6 W max.
100 to 240 VAC: 11 VA max.

24 VAC/VDC: 3.5 VA/3.3 W max.
100 to 240 VAC: 12.5 VA max.

 
 

*When an Expansion Unit is connected, the power consumption is increased by 2 VA/2 W max.

Inputs

Model

G9SA-301/321-T[]/TH301

G9SA-501

Input current *

40 mA max.

60 mA max

*When an Expansion Unit is connected, the input current is increased by 30 mA max.

Contacts

Model
Load

G9SA-301/501/321-T[]/TH301/EX301/EX031-T[]

 

Resistive load

 

Rated load

250 VAC, 5 A
30 VDC, 5 A

 
 

Rated carry current

5 A

 

Characteristics

Model

G9SA-301/TH301

G9SA-501/321-T[]

G9SA-EX301/EX031-T[]

Contact resistance *1

100 mΩ

Operating time *2

30 ms max.

Response time *3

10 ms max.

Insulation resistance *4

100 MΩ min. (at 500 VDC)

Dielectric
strength

Between different
outputs

2,500 VAC, 50/60 Hz for 1 min

Between inputs
and outputs

Between power
inputs and outputs

Between power inputs
and other inputs
(only for 100 to 240-V models)

Vibration resistance

10 to 55 to 10 Hz, 0.375-mm single amplitude
(0.75-mm double amplitude)

Shock
resistance

Destruction

300 m/s2

Malfunction

100 m/s2

Durability *5

Mechanical

5,000,000 operations min. (at approx. 7,200 operations/hr)

Electrical

100,000 operations min. (at approx. 1,800 operations/hr)

Failure rate (P Level) (reference value)

5 VDC, 1 mA

Ambient operating temperature

-25 to 55°C (with no icing or condensation)

Ambient operating humidity

35% to 85%

Terminal tightening torque

0.98 Nm

Weight *6

Approx. 210 g

Approx. 270 g

Approx. 130 g

*1.The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.
*2.Not Including bounce time.
*3.The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time.
*4.The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked.
*5.The durability is for an ambient temperature of 15 to 35? and an ambient humidity of 25% to 75%.
*6.Weight shown is for 24-VAC/VDC type. For 100 to 240-VAC type, add approximately 20 g.

Caution: In the interest of product improvement, specifications are subject to change without notice.






















  