No comment |
Product Description?
Four kinds of 45-mm wide Units are available:
A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a Two-hand Controller.
Also available are 17.5-mm wide Expansion Units with 3 poles and 3 OFF-delay poles.
Simple expansion connection.
OFF-delay models have 15-step OFF-delay settings.
Conforms to EN ISO13849-1 (Cat.4/PLe).
Both DIN track mounting and screw mounting are possible.
Specifications:
Model | G9SA-301/TH301 | G9SA-501 | G9SA-321-T[] |
|
Power supply | 24 VAC/VDC: 24 VAC, 50/60 Hz, or 24 VDC | |||
Operating | 85% to 110% of rated power supply voltage |
| ||
Power | 24 VAC/VDC: 1.8 VA/1.7 W max. | 24 VAC/VDC: 2.8 VA/2.6 W max. | 24 VAC/VDC: 3.5 VA/3.3 W max. | |
*When an Expansion Unit is connected, the power consumption is increased by 2 VA/2 W max.
Inputs
Model | G9SA-301/321-T[]/TH301 | G9SA-501 |
Input current * | 40 mA max. | 60 mA max |
*When an Expansion Unit is connected, the input current is increased by 30 mA max.
Contacts
Model | G9SA-301/501/321-T[]/TH301/EX301/EX031-T[] |
|
Resistive load |
| |
Rated load | 250 VAC, 5 A | |
Rated carry current | 5 A |
|
Characteristics
Model | G9SA-301/TH301 | G9SA-501/321-T[] | G9SA-EX301/EX031-T[] | |
Contact resistance *1 | 100 mΩ | |||
Operating time *2 | 30 ms max. | |||
Response time *3 | 10 ms max. | |||
Insulation resistance *4 | 100 MΩ min. (at 500 VDC) | |||
Dielectric | Between different | 2,500 VAC, 50/60 Hz for 1 min | ||
Between inputs | ||||
Between power | ||||
Between power inputs | ||||
Vibration resistance | 10 to 55 to 10 Hz, 0.375-mm single amplitude | |||
Shock | Destruction | 300 m/s2 | ||
Malfunction | 100 m/s2 | |||
Durability *5 | Mechanical | 5,000,000 operations min. (at approx. 7,200 operations/hr) | ||
Electrical | 100,000 operations min. (at approx. 1,800 operations/hr) | |||
Failure rate (P Level) (reference value) | 5 VDC, 1 mA | |||
Ambient operating temperature | -25 to 55°C (with no icing or condensation) | |||
Ambient operating humidity | 35% to 85% | |||
Terminal tightening torque | 0.98 Nm | |||
Weight *6 | Approx. 210 g | Approx. 270 g | Approx. 130 g |
*1.The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.
*2.Not Including bounce time.
*3.The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time.
*4.The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked.
*5.The durability is for an ambient temperature of 15 to 35? and an ambient humidity of 25% to 75%.
*6.Weight shown is for 24-VAC/VDC type. For 100 to 240-VAC type, add approximately 20 g.
Caution: In the interest of product improvement, specifications are subject to change without notice.
G9SA-301 OMRON RELAY NewProduct Description?
Four kinds of 45-mm wide Units are available:
A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a Two-hand Controller.
Also available are 17.5-mm wide Expansion Units with 3 poles and 3 OFF-delay poles.Simple expansion connection.
OFF-delay models have 15-step OFF-delay settings.
Conforms to EN ISO13849-1 (Cat.4/PLe).
Both DIN track mounting and screw mounting are possible.
Specifications:
Model
G9SA-301/TH301
G9SA-501
G9SA-321-T[]
Power supply
voltage24 VAC/VDC: 24 VAC, 50/60 Hz, or 24 VDC
100 to 240 VAC: 100 to 240 VAC, 50/60 HzOperating
voltage range85% to 110% of rated power supply voltage
Power
consumption*24 VAC/VDC: 1.8 VA/1.7 W max.
100 to 240 VAC: 9 VA max.24 VAC/VDC: 2.8 VA/2.6 W max.
100 to 240 VAC: 11 VA max.24 VAC/VDC: 3.5 VA/3.3 W max.
100 to 240 VAC: 12.5 VA max.*When an Expansion Unit is connected, the power consumption is increased by 2 VA/2 W max.
Inputs
Model
G9SA-301/321-T[]/TH301
G9SA-501
Input current *
40 mA max.
60 mA max
*When an Expansion Unit is connected, the input current is increased by 30 mA max.
Contacts
Model
LoadG9SA-301/501/321-T[]/TH301/EX301/EX031-T[]
Resistive load
Rated load
250 VAC, 5 A
30 VDC, 5 ARated carry current
5 A
Characteristics
Model
G9SA-301/TH301
G9SA-501/321-T[]
G9SA-EX301/EX031-T[]
Contact resistance *1
100 mΩ
Operating time *2
30 ms max.
Response time *3
10 ms max.
Insulation resistance *4
100 MΩ min. (at 500 VDC)
Dielectric
strengthBetween different
outputs2,500 VAC, 50/60 Hz for 1 min
Between inputs
and outputsBetween power
inputs and outputsBetween power inputs
and other inputs
(only for 100 to 240-V models)Vibration resistance
10 to 55 to 10 Hz, 0.375-mm single amplitude
(0.75-mm double amplitude)Shock
resistanceDestruction
300 m/s2
Malfunction
100 m/s2
Durability *5
Mechanical
5,000,000 operations min. (at approx. 7,200 operations/hr)
Electrical
100,000 operations min. (at approx. 1,800 operations/hr)
Failure rate (P Level) (reference value)
5 VDC, 1 mA
Ambient operating temperature
-25 to 55°C (with no icing or condensation)
Ambient operating humidity
35% to 85%
Terminal tightening torque
0.98 Nm
Weight *6
Approx. 210 g
Approx. 270 g
Approx. 130 g
*1.The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.
*2.Not Including bounce time.
*3.The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time.
*4.The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked.
*5.The durability is for an ambient temperature of 15 to 35? and an ambient humidity of 25% to 75%.
*6.Weight shown is for 24-VAC/VDC type. For 100 to 240-VAC type, add approximately 20 g.Caution: In the interest of product improvement, specifications are subject to change without notice.
No comment |