Your Position: Home > Low Voltage > Relay > G7T-1122S DC24V RELAY New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

G7T-1122S DC24V RELAY New

prevnext

G7T-1122S DC24V  RELAY  New
  • Market price: $ 29.7
  • Shop price: $ 9.0
  • Goods click count: 304
  • Total:
  • Quantity:
Add to cart collect
  

Description

G7T-1122S DC24V OMRON RELAY New

Product Description?

Product classification

Monostable relays
Standard type

Coil ratings

12 VDC 42 mA

Coil resistance

290 Ohm

Operate voltage (Set voltage)

80% Max.

Release voltage (Reset voltage)

10% Min.

Max. voltage

110% (of rated voltage)

Power consumption (Single stable)

0.5 W

Operating indicator

Mech indicator

Coil surge killer

Not equipped

Contact Type

SPST-NO

Contact method

Bifurcated crossbar

Contact material

Contact body material: Ag
Contact finish: AgAu-clad

Contact rated load

220 VAC 2 A (Resistive load)
220 VAC 1 A (Inductive load (cos phi = 0.4))
24 VDC 1 A (Resistive load)
24 VDC 0.5 A (Inductive load (L/R = 7 ms))

Maximum switching voltage

250 VAC (Resistive load)
250 VAC (Inductive load (cos phi = 0.4))
125 VDC (Resistive load)
125 VDC (Inductive load (L/R = 7 ms))

Maximum switching current

AC: 1 A (Resistive load)
AC: 1 A (Inductive load (cos phi = 0.4))
DC: 1 A (Resistive load)
DC: 1 A (Inductive load (L/R = 7 ms))

Maximum switching power

AC: 110 VA (Resistive load)
DC: 24 W (Resistive load)
DC: 12 W (Inductive load (L/R = 7 ms))

Failure rate

100 uA at 1 VDC (failure level: P Reference value)

Ambient temperature

Operating: -40 to 70 CEL
(with no icing or condensation)

Ambient humidity

Operating: 5 to 85% RH
(with no icing or condensation)

Characteristics

Contact resistance

Max. 50 mOhm, Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A

Operating time (set time)

15 ms Max.

Release time (Reset time)

15 ms Max.

Max.operating frequency (Mechanical)

18000 opn./h

Max.operating frequency (Erectrical)

1800 opn./h

Insulation resistance

Between coil and contacts: 100 MOhm Min. (at 500 VDC)
Between contacts of same polarity: 100 MOhm Min. (at 500 VDC)

Dielectric strength

Between coil and contacts: 2000 VAC 50/60 Hz for 1 min (Leakage current 2 mA 50/60 Hz 1 min)
Between contacts of same polarity: 1000 VAC 50/60 Hz for 1 min (Leakage current 2 mA 50/60 Hz 1 min)

Vibration resistance (Destruction)

10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) for 2 hours each in X, Y, and Z directions (No defect in appearance and construction after applying variable vibration in each directions for 2 hours.)

Vibration resistance (Malfunction)

10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) in each direction

Shock resistance (Destruction)

200 m/s**2 each direction 3 times (No defect in appearance and construction after applying shock in each directions 3 times.)

Shock resistance (Malfunction)

200 m/s**2

Endurance (Mechanical)

50000000 operations Min.

Endurance (Electrical)

50000 operations Min.

Protective structure

Closed type (cover)

Applicable standard (UL)

Standard No.: UL508
File No.: E41643

Applicable standard (CSA)

Standard No.: C22.2 No.14
File No.: LR35535

Terminal structure

Plug-in

Weight

Approx. 17 g
















  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: