G2R-1-DC12V OMRON RELAY New
Product Description?
Lockable test button models now available.
Built-in mechanical operation indicator.
Provided with nameplate.
AC type is equipped with a coil-disconnection self-diagnostic function (LED type).
High switching power (1-pole: 10 A).
Environment-friendly (Cd, Pb free).
Wide range of Sockets also available.
Specifications:
Rated voltage
Rated current*
Coil
resistance*Coil inductance (H)
(ref. value)Must
operate
voltageMust
release
voltageMax.
voltagePower
consumption
(approx.)50 Hz
60 Hz
Armature
OFFArmature
ON% of rated voltage
AC
24 V
43.5 mA
37.4 mA
253 Ω
0.81
1.55
80% max.
30% max.
110%
0.9 VA at 60 Hz
110 V
9.5 mA
8.2 mA
5,566 Ω
13.33
26.83
120 V
8.6 mA
7.5 mA
7,286 Ω
16.13
32.46
230 V
4.4 mA
3.8 mA
27,172 Ω
72.68
143.9
240 V
3.7 mA
3.2 mA
30,360 Ω
90.58
182.34
Rated voltage
Rated current*
Coil
resistance*Coil inductance (H)
(ref. value)Must
operate
voltageMust
release
voltageMax.
voltagePower
consumption
(approx.)Armature
OFFArmature
ON% of rated voltage
DC
6 V
87.0 mA
69 Ω
0.25
0.48
70% max.
15% min.
110%
0.53 W
12 V
43.2 mA
278 Ω
0.98
2.35
24 V
21.6 mA
1,113 Ω
3.6
8.25
48 V
11.4 mA
4,220 Ω
15.2
29.82
*The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%.
Contact Ratings
Number of poles
1 pole
2 poles
Load
Resistive load
(cosΦ = 1)Inductive load
(cosΦ = 0.4; L/R = 7 ms)Resistive load
(cosΦ = 1)Inductive load
(cosΦ = 0.4; L/R = 7 ms)Rated load
10 A at 250 VAC;
10 A at 30 VDC7.5 A at 250 VAC;
5 A at 30 VDC5 A at 250 VAC;
5 A at 30 VDC2 A at 250 VAC;
3 A at 30 VDCRated carry current
10 A
5 A
Max. switching voltage
440 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current
10 A
5 A
Max. switching power
2,500 VA, 300 W
1,875 VA, 150 W
1,250 VA, 150 W
500 VA, 90 W
Failure rate (reference value)
100 mA at 5 VDC
10 mA at 5 VDC
Note:P level: λ60 = 0.1 x 10-6/operation