Your Position: Home > Low Voltage > Relay > G2A-432A-N AC220V RELAY New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

G2A-432A-N AC220V RELAY New

prevnext

G2A-432A-N AC220V  RELAY  New
  • Market price: $ 16.5
  • Shop price: $ 5.0
  • Goods click count: 351
  • Total:
  • Quantity:
Add to cart collect
  

Description

G2A-432A-N AC220V OMRON RELAY New

 Product Description?

Standard Model , Plug-In Type , 4PDT , Built-In Indicator

Specifications:

Product classification

Monostable relays
Built-in LED indicator type

Coil ratings

200 VAC 8.7 mA (50 Hz), 200 VAC 7 mA (60 Hz), 220 VAC 10.8 mA (50 Hz), 220 VAC 8.4 mA (60 Hz)

Coil resistance

8800 Ohm

Operate voltage (Set voltage)

80% Max.

Release voltage (Reset voltage)

30% Min. (50 Hz), 30% Min. (60 Hz)

Max. voltage

110% (of rated voltage)

Power consumption (Single stable)

1.4 VA (50 Hz)
1.4 VA (60 Hz)

Operating indicator

LED indicator

Coil surge killer

Not equipped

Contact Type

4PDT

Contact method

Bifurcated crossbar

Contact material

Contact body material: AgPd
Contact finish: Movable: Au-clad; Fixed: Nothing

Contact rated load

110 VAC 0.3 A (Resistive load)
110 VAC 0.2 A (Inductive load (cos phi = 0.4))
24 VDC 0.5 A (Resistive load)
24 VDC 0.3 A (Inductive load (L/R = 7 ms))

Maximum switching voltage

250 VAC (Resistive load)
250 VAC (Inductive load (cos phi = 0.4))
125 VDC (Resistive load)
125 VDC (Inductive load (L/R = 7 ms))

Maximum switching current

AC: 1 A (Resistive load)
AC: 0.75 A (Inductive load (cos phi = 0.4))
DC: 3 A (Resistive load)
DC: 1.5 A (Inductive load (L/R = 7 ms))

Maximum switching power

AC: 110 VA (Resistive load)
AC: 80 VA (Inductive load (cos phi = 0.4))
DC: 70 W (Resistive load)
DC: 36 W (Inductive load (L/R = 7 ms))

Failure rate

1 mA at 100 mVDC (failure level: P Reference value)

Ambient temperature

Operating: -10 to 40 CEL
(with no icing or condensation)

Ambient humidity

Operating: 5 to 85% RH
(with no icing or condensation)

Characteristics

Contact resistance

Max. 100 mOhm, Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 100 mA

Operating time (set time)

15 ms Max.

Release time (Reset time)

15 ms Max.

Max.operating frequency (Mechanical)

18000 opn./h

Max.operating frequency (Erectrical)

1800 opn./h

Insulation resistance

Between coil and contacts: 100 MOhm Min. (at 500 VDC)
Between contacts of different polarity: 100 MOhm Min. (at 500 VDC)
Between contacts of same polarity: 100 MOhm Min. (at 500 VDC)

Dielectric strength

Between coil and contacts: 1500 VAC 50/60 Hz for 1 min (Leakage current 10 mA 50/60 Hz 1 min)
Between contacts of different polarity: 1500 VAC 50/60 Hz for 1 min (Leakage current 10 mA 50/60 Hz 1 min)
Between contacts of same polarity: 700 VAC 50/60 Hz for 1 min (Leakage current 10 mA 50/60 Hz 1 min)

Vibration resistance (Destruction)

10 to 55 to 10 Hz 0.75-mm single amplitude (1.5-mm double amplitude) for 2 hours each in X, Y, and Z directions (No defect in appearance and construction after applying variable vibration in each directions for 2 hours.)

Vibration resistance (Malfunction)

10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) in each direction

Shock resistance (Destruction)

1000 m/s**2 each direction 3 times

Shock resistance (Malfunction)

100 m/s**2

Endurance (Mechanical)

100000000 operations Min.

Endurance (Electrical)

5000000 operations Min.

Protective structure

Closed type (cover)

Terminal structure

Plug-in

Weight

Approx. 38 g















  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: