Your Position: Home > Instrumentation > Digital multimeter > Multimeter 4 1/2 Logging of True-rms digital VC187 VICTOR

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

Multimeter 4 1/2 Logging of True-rms digital VC187 VICTOR

prevnext

Multimeter 4 1/2 Logging of True-rms digital VC187  VICTOR
  • NO.: VC187
  • Weight: 500gram
  • Market price: $ 1254.0
  • Shop price: $ 380.0
  • Goods click count: 335
  • Total:
  • Quantity:
Add to cart collect
  

Description

PLCAGE:Multimeter 4 1/2 Logging of True-rms digital

VC187  VICTOR

 

Characteristics

l Measurements

AC voltage, DC voltage, AC current ,DC current, OHM, Frequency, Period, Pulse width,Capacitance, Beep, Diode, dBm, Thermocouple (TC), Thermal resistance (RTD), AC+ DC, AC + Hz measurement, Maximum, Minimum, Average measurement (MAX / MIN / AVG), The relative value measurement (REL_%)

l Measurements show that 55,000 words, the basic accuracy 0.02% (VICTOR 189) / 0.05% (VICTOR 187)

l Three measurement rate: FAST, SLOW, SMOOTH, the fastest refresh rate of simulation bar: 14 / sec

l Manual range or automatic range selection

l Measuring data show that hold functional (DIS_HOLD) and automatically hold functions(AUTO_HOLD)

l Peak measurements, 500us peak sampling capture, capable of capturing crest Pulse

l AC voltage and AC current are true rms measurement, AC voltage bandwidth 20Hz~30KHz(VICTOR 187),20Hz-100KHz(VICTOR 189), AC current bandwidth 20Hz-30KHz

l Option 1 ~ 2400 Ω reference impedance measurement of decibels

l Low pass filter function normally by the RP-raising and the frequency of the electrical waveform measurement results

l Can be configured clamp to measure the large current

l The eight kinds of thermocouple measurement, the two kinds of heat resistance measurement, high-precision cold-automatic compensation, ? or ? temperature display

l Large-screen display and more data can be displayed at the same time that is measurements and other information related to the measurement

l Built-in real-time clock, for the record and provide accurate measurement of time

l Easy to operate multi-parameter data record: manual records and records of the incident, and easy to query the data records

l Adopted panel calibration technology, can be done without opening the case calibration

l Use alkaline batteries, Ni-Hi battery-powered, the battery and fuse can be easily replaced.

l Backlight is automatically closed and automatic power off function

l Large-screen LCD display, with white LED backlighting

l The meter can communicate with computer by isolation interface USB

l Through the friendly interface, users can easily access the data of instrument in a number of parameters, and may be the data storage, processing, management, access to the data tables and other graphics or display

l Simple man-machine operating, delicate, strongly and suitable for field use

Specifications for products

Measurements

Range

Measuring range

Resolution

DCV

5.0000V

0.0001V

Input impedance:

10MΩ

50.000V

0.001V

500.00V

0.01V

1000.0V

0.1V

DCmV

50.000mV

0.001mV

Input impedance:

approx. 100MΩ

500.00mV

0.01mV

2200.0mV

0.1mV

ACV 

5.0000V

0.0001V

Input impedance:

10MΩ / 50pF

CF<3

187:

20Hz~30kHz

(10~110% Range)

189:

20Hz~100kHz

(5~110% Range)

50.000V

0.001V

500.00V

0.01V

760.0V

0.1V

ACmV 

50.000mV

0.001mV

Input impedance:

1MΩ / 50pF

500.00mV

0.01mV

OHM

500.00Ω

0.01Ω

Open circuit voltage

<2.5V

5.0000KΩ

0.0001KΩ

50.000KΩ

0.001KΩ

500.00KΩ

0.01KΩ

5.0000MΩ

0.0001 MΩ

50.000MΩ

0.001 MΩ

500.0MΩ

0.1 MΩ

DCA

5.0000A

0.0001 A

Voltage Drop <0.04 V/A

20.000A

0.001 A

DCmA

50.000mA

0.001mA

Voltage Drop

<1.8 mV/mA

500.00mA

0.01 mA

DCuA

500.00uA

0.01 uA

Voltage Drop

103uV/uA

5000.0uA

0.1 uA

5.0000A

0.0001 A

ACmA

50.000mA

0.001mA

500.00mA

0.01 mA

ACuA

500.00uA

0.01uA

50000uA

0.1uA

FREQ

9.9999Hz

0.0001Hz

 

99.999Hz

0.001Hz

999.99Hz

0.01Hz

9.9999KHz

0.0001KHz

99.999KHz

0.001KHz

999.99KHz

 

0.01KHz

  

9.9999MHz

0.0001MHz

99.999MHz

0.001MHz

   

DUTY

0.1%~99.9%

0.1%

0.5Hz~1KHz,

Square Wave

 

PULSE

199.99ms

0.01ms

1999.9ms

0.1ms

DIODE

2.2000V

0.0001V

Open circuit voltage:<3.5V

Short circuit:0.8mA

CHCNT

500.0Ω

0.1Ω

Open circuit voltage:<3.5V

Short circuit:<0.8mA

Short alarm:approx. <20Ω

Open alarm:approx. >120Ω

CAP

9.999nF

0.001nF

 

99.99nF

0.01nF

999.9nF

0.1nF

9.999μF

0.001uF

99.99μF

0.01uF

999.9μF

0.1uF

9.999mF

0.001mF

99.99mF

0.01mF

TC

R

-40°C~1760°C

1°C

ITS-90

S

-40°C~1760°C

K

-270.0~1370.0

0.1°C

E

-270.0~720.0

0.1°C

J

-210.0~850.0

0.1°C

T

-270.0~400.0

0.1°C

N

-270.0~1300.0

0.1°C

B

400~1800

1°C

RTD

Pt100

-200.0~850.0

0.1°C

Pt100-385

Pt1000

-200.0~630.0

0.1°C

 

Other Features:

l DC Voltage measurement

CMRR:50Hz / 60Hz ≥ 120dB

SMRR:50Hz / 60Hz(Rs=1kΩ) ≥ 80dB

l AC Voltage measurement

CMRR:50Hz / 60Hz(Rs=1kΩ) ≥ 80 dB

A residual reading with input shorted, will not affect stated accuracy above 5 % of range.

l OHM measurement

For relative humidity greater than 70 %, resistance accuracy is 0.5 % over 1 MΩand 2.5 % over 10 MΩ.

l Internal temperature compensation sensor RJC:

temperature range: -10 ~ 50?, compensation error ≤ ± 0.5 ?, compensation time for 10 seconds each time

l Maximum voltage between any Terminal and Earth Ground :

1000V DC / AC rms
Fuse protection for mA input: 500 mA / 250V FAST fuse
fuse protection for 20A input: 20 A / 250V FAST fuse
Can be as high as 20 A continuous measurement of the current, if the signal detected in 10 A ~ 20 A of maintaining maximum of 30 seconds, then specified the need to increase the accuracy of 0.5%

l Real-Time Clock
≤ ± 1min / 1month
Temp. Influence 50 ppm per C

l Measured rate

Functional range

Measuring rate

FAST

SLOW

SMOOTH

DC voltage and current

14

7

1

AC voltage and current

14

/

1.8

Resistors, diodes, on-off

7

/

1.8

 

General Specifications:

l Operating Temperature and Humidity

0 to 50oC,(no condensation ≤10oC) ≤ 85%RH

l Storage Temperature and Relative Humidity

-20oC to 60oC,≤90%RH

l Altitude

2000m max. above sea level

l Rated transient over-voltage 

6KV(1.2*50us)CAT?, CAI ?, CAT ? peak measurement

l Vibration and Shock

Random 2g, 5 to 500Hz

1 meter drop test

l Period of calibration and warm-up time

Accuracy is specified for a period of one year after calibration or other

Warm-up time is 10 minutes or other

l Display and LED

* LCD:36.3×68.0mm

* white LED,able to set time 0~9999S

l Supply

* 4 x 1.5V Alkaline batteries supply

               * 4 x 1.2V Ni-Hi batteries supply

               * Auto Power-off:able to set time 0~9999minutes

l Safety Standards

IEC 61010-1, 2000

Overvoltage category III (Max. input voltage:AC/DC600V)

Overvoltage category II (Max. input voltage:AC/DC1000V)

Pollution degree 2

l Weight and Size

205 × 95 × 42(mm) ,approximate 500g

 





  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: