PLCAGE:Multimeter digital VC79 VICTOR
Meansuring function
Range
Measuring range
Resolving power
Accuracy
Remark
DC Voltage
4V
-4.000V~4.000V
1mV
0.2%+4
Input impedance:10MΩ
40V
-40.00V~40.00V
0.01V
0.2%+4
400V
-400.0V~400.0V
0.1V
0.2%+4
AC Voltage
400mV
0~400.0mV
0.1mV
1%+4
Input impedance:10MΩ
<100pF
4V
0~4.000V
1mV
0.5%+4
40V
0~40.00V
0.011V
0.5%+4
400V
0~400.0V
0.1V
0.5%+4
DC Mv Voltage
40mV
-40.00mV~40.00mV
0.01mV
0.2%+4
Input impedance:10MΩ
400mV
-400.0mV~400.0mV
0.1mV
0.2%+4
OHM
400Ω
0~400.0Ω
0.1Ω
0.2%+4
Plough voltage:0.4V
Not including the accuracy of down-lead resistance
4kΩ
0~4.000kΩ
1Ω
0.2%+4
40kΩ
0~40.00kΩ
0.01kΩ
0.2%+4
400kΩ
0~400.0kΩ
0.1kΩ
0.2%+4
4MΩ
0~4.000MΩ
1kΩ
0.2%+4
40MΩ
0~40.00MΩ
0.01MΩ
1%+4
DC Current
40mA
-40.00mA~40.00mA
0.01mA
0.2%+4
Input impedance:1Ω
400mA
-400.00mA~400.00mA
0.1mA
0.2%+4
AC Current
40mA
0~40.00mA
0.01mA
0.5%+4
Input impedance:1Ω
400mA
0~400.00mA
0.1mA
0.5%+4
Frequency
50Hz
0~50.0 Hz
0.01Hz
0.1%+3
500Hz
0~500.0 Hz
0.1Hz
0.1%+3
5kHz
0~5.000 kHz
1Hz
0.1%+3
50kHz
0~50.00k Hz
0.01kHz
0.1%+3
100kHz
0~100.0k Hz
0.1kHz
0.1%+3
Duty cycle
0.1%~99%
0.1%
1%
Diode test
1V
0.001V
10%
Plough voltage 1.1V~1.6V
Current of short circuit:0.6mA
Continuity test
≤50ΩBB
0.1Ω
Thermocouple
R
-40?~1760?
1?
0.5%+3(≤100?) 0.5%+2( >100?)
Adopt ITS-90 thermometric scale not including the accuracy of RJC error RJC error: ±2?
S
-20?~1760?
K
-200?~950?
0.2%+2(≤100?)
0.5%+1( >100?)
E
-200?~500?
J
-200?~700?
T
-200?~400?
N
-200?~1000?
0.5%+3(400~600?)
0.5%+2( >600?)
B
400?~1800?
Thermo resistance
Pt100
-200?~700?
1?
0.5%+2
Pt100-385 thermometric scale. Not including the accuracy of down-lead resistance
Cu50
-50?~150?
0.5%+4
Output function:
Function
Range
Setting range
Resolving power
Accuracy
Remark
OHM
400Ω
0~400.0Ω
0.1Ω
0.2%+4
±1mAcurrent not includingthe accuracy of down-lead resistance
DCmV
100mV
-10.00mV~110.00mV
0.01mV
0.2%+4
Max output current:5mA
DCV
5V
-0.5000V~5.5000V
1mV
0.2%+4
Max output current5mA
FREQ
100Hz
1.0Hz~110.0Hz
0.1Hz
0.2%+2
50% Duty cycle 5V p-p
1kHz
0.100Hz~1.100Hz
0.001kHz
0.2%+2
10kHz
1.0kHz~11.0kHz
0.1kHz
0.2%+2
Analog transducer XMT
-20mA
0~-22.000mA
0.01mA
0.2%+4
Outside power supply 28V when 20mA 1kΩ resistance
DC Mv
20mA
0~22.000mA
0.01mA
0.2%+4
Outside power supply 15V when 20mA
400Ω resistance
Thermocouple
R
-40?~1760?
1?
0.2%+3
(≤100?)
0.2%+2
( >100?)
Adopt ITS-90 thermometric scale not including the accuracy of RJC error RJC error: ±2?
S
-20?~1760?
0.1?
K
-200?~1370?
0.2%+20
(≤-100?)
0.2%+10
( >-100?)
E
-200?~1000?
J
-200?~1200?
T
-200?~400?
N
-200?~1300?
B
400?~1800?
1?
0.2%+3
(400~600?)
0.2%+2
( >600?)
Thermo resistance
Pt100
-200?~850?
0.1?
0.2%+6
Pt100-385 thermometric scale±1mA not including the accuracy of down-lead resistance
Cu50
-50?~150?