No comment |
>
Control System >
VFD >
FUJI VFD >
FRN220F1S-4C Inverter 220kw FRENIC-VP Fan And Pump Type
400V Three-phase 415A 220KW FRN220F1S-4C FUJI FRENIC-VP Inverter
Features
1. The effect of energy saving has updated again.
2. Simple structure, convenient manufacturing.
3. Durable design-10 years using life.
4. Fit with the HVAC (Hole Ventilator Air conditioner).
5. The design is fully considering the ambient and controlled board.
6. Easy operating
Standard Specifications
Three-phase 400V Series
3.7~55KW
Item
Specifications
Type(FRNxxxF1S-4Cxxx)
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
Nominal applied motor [KW]
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
Output ratings
Rated capacity[KVA]
6.8
9.5
12
17
22
28
33
44
54
64
77
Rated voltage[V]
Three-phase 380 to 480V(with AVR)
Rated Current[A]
9.0
12.5
16.5
23
30
37
44
59
72
85
105
Rated Overload capability
120% for 1min
Rated frequency[Hz]
50,60Hz
Input Rating
Rated current[A]
With DCR
7.5
10.6
14.4
21.1
28.8
35.5
42.2
57.0
68.5
83.2
102
Without DCR
13.0
17.3
23.2
33.0
43.8
52.3
60.6
77.9
94.3
114
140
Required power supply capacity[KVA]
With DCR
5.3
7.4
10
15
20
25
30
40
48
58
71
Braking
Torque[%]
20
10 to 15
DC injection braking
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%
DC reactor (DCR)
Optional
Applicable safety standards
UL508C, C22.2No.14, EN50178: 1997
Enclosure (IEC60529)
IP20 (IEC60529) closed type, UL open type
IP00 open type, UL open type
Cooling method
Fan cooling
Weight/Mass[kg]
3.4
3.4
5.8
6.0
6.9
9.4
9.9
11.5
23
24
33
7.5~560KW
Item
Specifications
Type(FRNxxxF1S-4Cxxx)
75
90
110
132
160
200
220
280
315
355
400
450
500
560
Nominal applied motor [KW]
75
90
110
132
160
200
220
280
315
355
400
450
500
560
Output ratings
Rated capacity[KVA]
105
128
154
182
221
274
316
396
445
495
563
640
731
792
Rated voltage[V]
Three-phase 380 to 480V(with AVR)
Rated Current[A]
139
168
203
240
290
360
415
520
585
650
740
840
960
1040
Rated Overload capability
120% for 1min
Rated frequency[Hz]
50,60Hz
Input Rating
Rated current[A]
With DCR
138
164
201
238
286
357
390
500
559
628
705
789
881
990
Without DCR
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Required power supply capacity[KVA]
With DCR
96
114
140
165
199
248
271
347
388
435
489
547
611
686
Braking
Torque[%]
10 to 15
DC injection braking
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%
DC reactor (DCR)
Standard
Applicable safety standards
UL508C, C22.2No.14, EN50178: 1997(applying)
Enclosure (IEC60529)
IP00 open type, UL open type
Cooling method
Fan cooling
Weight/Mass[kg]
34
42
45
63
67
96
98
162
165
282
286
355
360
360