No comment |
>
Control System >
VFD >
Delta VFD >
Delta Inverter VFD drive VFD001L21A 1Phase 220V 0.1kW 0.125HP 1~120Hz Wood cutting &Wire drawing1 Phase to 3 Phase Delta VFD Drive 220V 0.1KW 0.125H VFD001L21A Inverter
Sub-fractional low cost AC Drive. Specifically designed for low horsepower applications with built-in EMI filter to efficiently reduce electromagnetic interference and to conform to the CE EMI directive.
Specifications
1. 16-bit microprocessor controlled SVPWM output.
2. Low noise; carrier frequency up to 10kHz.
3. Controlled reversing.
4. 2 inputs and 1output terminal for external controls.
5. Adjustable V/F curve.
6. Adjustable accel/decal time
7. RS-485 communication (Baud rate 9600)
8. Option: Programmable Keypad (VFD-PU02)
Applications
Simple wood cutting, conveyer belt, wire drawing machine, etc
Standard Specifications:
Voltage Class
115V Class
230V Class
Model Number VFD-XXX L XXA/B
40W
001
40W
001
Weight g (lb) A (standard)
270 (0.60)
440 (0.97)
260 (0.57)
430 (0.95)
Weight g (lb) B (build-in EMI filter)
350 (0.77)
525 (1.16)
340 (0.75)
510 (1.12)
Max. Applicable Motor Output (W)
25/40
60/100
25/40
60/100
Output Rating
Rated Output Capacity (VA)
106/152
212/303
106/152
212/303
Rated Output Current (A)
0.28/0.4
0.56/0.8
0.28/0.4
0.56/0.8
Maximum Output Voltage (V)
Two times proportion to
Input Voltage
Proportional to Input
Voltage
Rated Frequency (Hz)
1.00 to 120.00 Hz
Input Rating
Rated Voltage/Frequency
Single phase
100 to 120 VAC
50/60 Hz
Single phase
200 to 240 VAC 50/60Hz
Voltage/Freq. Tolerance
Voltage: ±10%, Frequency: ±5%
Input Current (A)
1.1A
1.5A
2.2A
3.0A
0.5A
0.7A
1.0A
1.4A
Control
Characteristics
Control Systems
SVPWM (Space Vector Pulse Width Modulation,
carrier frequency 10kHz)
Torque Setting
High/Low, Switching
Overload Endurance
150% of rated current for 1 minute
Accel/Decel Time
0.05 to 30.0 seconds
Torque Promotion
Torque Boots: 0 or 8%
Operation Characteristics
Frequency Setting
Potentiometer
Operation Setting Signal
Panel
RUN/STOP, FORWARD/REVERSE
Ext. Terminal
RUN/STOP, FORWARD/REVERSE, RS-485
Output Indiction
Panel
Fault Indication (LED Flash)
Ext. Terminal
Fault Indication (Open Collector)
Protection
Self-testing, Over Voltage, Over Current, Under
Voltage, Overload, Overheating, Thermal.
Cooling
Natural air-cooling
Environment
Installation Location
Altitude 1,000m or lower, keep from corrosive
gasses, liquid and dust
Pollution Degree
2
Ambient Temperature
-10oC to 40oC (Non-Condensing and not frozen)
Storage Temperature
-20oC to 60oC
Ambient Humidity
Below 90% RH (non-condensing)
Vibration
9.80665m/s2
(1G) less than 20Hz, 5.88m/s2
(0.6G) at 20 to 50Hz
Basic Wiring Diagram:
Users must connect wiring according to the following circuit diagram shown below.
Installation Dimension:
No comment |