Your Position: Home > Control System > PLC > Other PLC > G4F-AT3A LS PLC K300S Series Analog Timer Module 8 Analog Timers Setting Range 0.1~1.0sec/1~10sec 10~60sec/60~100sec New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

G4F-AT3A LS PLC K300S Series Analog Timer Module 8 Analog Timers Setting Range 0.1~1.0sec/1~10sec 10~60sec/60~100sec New

prevnext

G4F-AT3A LS PLC K300S Series Analog Timer Module 8 Analog Timers Setting Range 0.1~1.0sec/1~10sec 10~60sec/60~100sec New
  • Market price: $ 419.1
  • Shop price: $ 127.0
  • Goods click count: 356
  • Total:
  • Quantity:
Add to cart collect
  

Description

G4F-AT3A LS PLC K300S Series Analog Timer Module 8 Analog Timers Setting Range 0.1~1.0sec/1~10sec 10~60sec/60~100sec New

PLCAGE: G4F-AT3A LS PLC K300S Series Analog Timer Module 8 Analog Timers Setting Range 0.1~1.0sec/1~10sec 10~60sec/60~100sec New

Introduction:

Powerful & compact module-type PLC K200S & K300S are module-type PLC that consist of various modules including basic module(CPU, Power, I/O), communication module and special module. And through various modules, user can configure the optimum system for industry environment

Features:

*Small- and medium-scale control with 1,024 points

*High-speed processing: 0.2us/step

*On-line editing

*Change I/O value by force

*Small- and medium-sized manufacture line control by network

*Downsizing and high performance

*Various special modules: analog, HSC, PID, positioning, etc

Specification:

Items

Specifications

G3F - AT4A

G4F - AT3A

Timer point

16 points

8 points

Timer setting value range

0.1 to 1.0 sec

1 to 10 sec

10 to 60 sec

60 to 600 sec

Setting can be done for each individual point

Backup Method

For backup, set the operation mode selection switch to the TEST side.

Setting Method

Setting by the adjustment volume.

Timer Accuracy

± 2.0% (For maximum value)

Operating Indicator

Timer Operation indication LED : 16 pts

Timer Operation indication LED : 8 pts

Timer Contact indication LED : 16 pts

Timer Contact indication LED : 8 pts

Current consumption

0.3 A (5 VDC)

0.2 A (5VDC)

      

Application

Customer willing to use IEC language

LCD/PDP field

Auto (auto/car accessories) field

Raw materials(chemical/glass/iron/steel) field

Field of water treatment and boiler

Other hot items of this LS PLC K300S series for above applications:

Items

Module No.

Description

Remark

 

A/D conversion modules

G4F-AD2A

Voltage /current input,4 channels

-5-5VDC/-10-10VDC

DC-20-20mA

 

G4F-AD3A

Voltage /current input,8 channels

1-5VDC/0-10VDC

DC4-20Ma

 

D/A conversion modules

G4F-DA1A

Voltage/current output,2 channels

-10-10VDC,DC4-20mA

 

G4F-DA2V

Voltage/current output,4 channels

-10-10VDC

 

G4F-DA2I

Voltage/current output,2 channels

DC4-20mA

 

G4F-DA3V

Voltage/current output,2 channels

-10-10VDC

 

G4F-DA3I

Current output,8 channels DC4-20mA

 

High speed counter module

G4F-HSCA

Counting range(0-16,777,215:binary 24 bits)50kHz,1 channel

 

Positioning module

G4F-POPA

Pulse output,1axis control

 

G4F-POPB

Pulse output,2axis control

 

Thermocouple input module

G4F-TC2A

Sensor type:7 types(K,J,E,T,B,R,S)

4 channels

 

RTD module

G4F-RD2A

Sensor type:Pt100,JPt100 4 channels

 

PID control module

G4F-PIDA

Max,8loops control

 

Analog timer module

G4F-AT3A

8 analog timers

Setting range:0.1-1.0sec/1-10sec

10-60sec/60-600sec

Each channel can be set independently

Interrupt module

G4F-INTA

8 channels

 

  

User Comment