Features:
*Low I/O points: 1024.
*Low speed processing: 0.2 us/step.
*It can be programming in low running condition.
*It can be forced to inputing oroutputing
*Low of large and medium-sized network system can be realized.
*With a number of special modules: simulation, PID, TC, RTD, position control, high speed counter.
*With system monitoring function.
*Fast Enet, Cnet, Fnet, Rnet, profibus-dp can be supported.
Specifications
Type Item | K1000S | ||
G3Q-RY4A | |||
Output points | 32 points | ||
Insulation method | Photo coupler | ||
Rated load voltage / current | Per 1 point | 24 VDC / 2A (resistive load), 220 VAC / 2A (cosψ = 1) | |
Per 1 COM | 5A / 1COM | ||
Minimum load voltage / current | 5 VDC / 1mA | ||
Maximum load voltage | 125 VDC / 250 VAC | ||
Leakage current | 0.1 mA ( 220 VAC, 60Hz ) | ||
Maximum switching frequency | 3,600 times / hour | ||
Surge absorber | None | ||
Lifet ime of contact | Mechanical | No load Over 20 million times | |
Electrical | Rated voltage / current Over0.1 million times | ||
200VAC / 1.5A, 240VAC / 1A (cosψ = 0.7) Over 0.1 million times | |||
200VAC / 1A, 240VAC / 0.5A (cosψ = 0.35) Over 0.1 million times | |||
24VDC / 1A, 100VDC / 0.1A (L / R = 7ms) Over 0.1 million times Over 0.1 million times | |||
Response time | Off -> On | 10 msec or less | |
On -> Off | 12 msec or less | ||
Common method | 8 point / 1COM | ||
Internal current consumption | 200mA (when all outputs are on) | ||
Weight | 550g | ||
G3Q-RY4A LS PLC K1000S Series Digital Output Module Relay Output 32 Points 1A/Point NewPLCAGE: G3Q-RY4A LS PLC K1000S Series Digital Output Modules 32 Points 1A/Point Relay New
Features:
*Low I/O points: 1024.
*Low speed processing: 0.2 us/step.
*It can be programming in low running condition.
*It can be forced to inputing oroutputing
*Low of large and medium-sized network system can be realized.
*With a number of special modules: simulation, PID, TC, RTD, position control, high speed counter.
*With system monitoring function.
*Fast Enet, Cnet, Fnet, Rnet, profibus-dp can be supported.
Specifications
Type
Item
K1000S
G3Q-RY4A
Output points
32 points
Insulation method
Photo coupler
Rated load
voltage / current
Per 1 point
24 VDC / 2A (resistive load), 220 VAC / 2A (cosψ = 1)
Per 1 COM
5A / 1COM
Minimum load voltage / current
5 VDC / 1mA
Maximum load voltage
125 VDC / 250 VAC
Leakage current
0.1 mA ( 220 VAC, 60Hz )
Maximum switching frequency
3,600 times / hour
Surge absorber
None
Lifet ime of contact
Mechanical
No load Over 20 million times
Electrical
Rated voltage / current Over0.1 million times
200VAC / 1.5A, 240VAC / 1A (cosψ = 0.7) Over 0.1 million times
200VAC / 1A, 240VAC / 0.5A (cosψ = 0.35) Over 0.1 million times
24VDC / 1A, 100VDC / 0.1A (L / R = 7ms) Over 0.1 million times Over 0.1 million times
Response time
Off -> On
10 msec or less
On -> Off
12 msec or less
Common method
8 point / 1COM
Internal current consumption
200mA (when all outputs are on)
Weight
550g