FX3U-4DA Mitsubishi PLC special function block Original Brand NEW


Introduction

The FX3U-4DA special function block for analog output converts digital values supplied from PLC into analog values (voltage, current) and outputs those analog values from its four output points.

Applicable PLC

Model name

Applicability

FX3U Series PLC

Ver. 2.20 or later (from first production)

Up to 8 blocks can be extended

FX3UC Series

PLC

Ver. 1.30 or later (from the production manufactured in August,

2004 with SER No. 48…)

Up to 8 blocks can be extended

Power Supply Specifications

Item

Specification

D/A conversion

circuit driving power

24V DC +-10%, 160mA

(24V DC power is supplied from the power connector.)

CPU driving power

5V DC, 120mA

(5V DC power is supplied from the internal power supply of main unit.)

Performance Specifications

Item

Description

Voltage output

Current output

Analog output

range

-10 to +10V DC

(External load: 1k ohm to 1Mohm)

 

0 to 20mA, 4 to 20mA DC

(External load: 500 ohm or less)

Offset

-10 to +9V

0 to 17mA

Gain

-9 to +10V

3 to 30mA

Digital input

With sign, 16bits, binary

15bits, binary

Resolution

0.32mV (20V/64000)

0.63uA (20mA/32000)

Total accuracy

+-0.3% (+-60mV) for full scale of 20V (when ambient

temperature is 25°C±5°C)

+-0.5% (+-100mV) for full scale of 20V (when ambient

temperature is 0°C to 55°C)

+-0.3% (±60µA) for full scale of 20mA (when ambient

temperature is 25°C±5°C)

+-0.5% (+-100uA) for full scale of 20mA (when ambient temperature is 0°C to 55°C)

A/D conversion

time

1ms (The number of selected channels will not affect this value.)

Insulation

method

The photo-coupler insulates the analog output area from the

PLC.

The DC-DC converter insulates the analog output area from the power supply unit.

Channels are not insulated from each other

Occupied points

8 point (Count either the input or output points of the PLC.)

External Dimension


  