No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
TL-N20MY1 Proximity Switch NEWOMRON Proximity Switch TL-N20MY1
Product Description:
Easy installation, high-speed pulse generator, high-speed rotation control, and more.
Direct mounted to metal (-N Models).
A wealth of models ideal for limit control, counting control, and other applications (-N Models).
Specifications:
Model | TL-N5ME[], TL-N5MY[] | TL-N10ME[], TL-N10MY[] | TL-N20ME[], TL-N20MY[] | |
Sensing distance | 5 mm ±10% | 10 mm ±10% | 20 mm ±10% | |
Set distance | 0 to 4 mm | 0 to 8 mm | 0 to 16 mm | |
Differential travel | 15% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) | |||
Standard sensing object | Iron, 30 × 30 × 1 mm | Iron, 40 × 40 × 1 mm | Iron, 50 × 50 × 1 mm | |
Response frequency *1 | E Models: 500 Hz | E Models: 40 Hz | ||
Y Models: 10 Hz | Y Models: 10 Hz | |||
Power supply voltage *2 | E Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | |||
(operating voltage range) | Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz | |||
Current consumption | E Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC | |||
Leakage current | Y Models: Refer to Engineering Data on Data Sheet. | |||
Control | Load current | E Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC | ||
output | Y Models: 10 to 200 mA | |||
| Residual | E Models: 1 V max. (load current: 200 mA) | ||
| voltage | Y Models: Refer to Engineering Data on Data Sheet. | ||
Indicators | E Models: Detection indicator (red) | |||
Y Models: Operation indicator (red) | ||||
Operation mode (with | E1/Y1 Models: NO | |||
sensing object approaching) | E2/Y2 Models: NC | |||
| Refer to the timing charts under I/O Circuit Diagrams onData Sheet for details. | |||
Protection circuits | E Models: Reverse polarity protection, Surge suppressor | |||
Y Models: Surge suppressor | ||||
Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
Voltage influence | E Models: ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range | |||
Y Models: ±1% max. of sensing distance at rated voltage in rated voltage ±10% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | E Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
Weight (packed state) | Approx. 145 g | Approx. 170 g | Approx. 240 g | |
Materials | Case | Heat-resistant ABS | ||
Sensing | ||||
surface | ||||
Accessories | E Models: | E Models: | E Models: | |
Mounting Bracket, | Mounting Bracket, | Mounting Bracket, | ||
Mounting phillips screws (M4 × 25), | Mounting phillips screws (M4 × 30), | Mounting phillips screws (M5 × 40), | ||
Instruction manual | Instruction manual | Instruction manual | ||
Y Models: | Y Models: | Y Models: | ||
Instruction manual | Instruction manual | Instruction manual |
*1.The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2.E Models (DC switching models): A full-wave rectification power supply of 24 VDC ±10% (average value) can be used.
TL-N20MY1 OMRON Proximity Switch NEWOMRON Proximity Switch TL-N20MY1
Product Description:
Easy installation, high-speed pulse generator, high-speed rotation control, and more.
Direct mounted to metal (-N Models).
A wealth of models ideal for limit control, counting control, and other applications (-N Models).
Specifications:
Model
TL-N5ME[], TL-N5MY[]
TL-N10ME[], TL-N10MY[]
TL-N20ME[], TL-N20MY[]
Sensing distance
5 mm ±10%
10 mm ±10%
20 mm ±10%
Set distance
0 to 4 mm
0 to 8 mm
0 to 16 mm
Differential travel
15% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.)
Standard sensing object
Iron, 30 × 30 × 1 mm
Iron, 40 × 40 × 1 mm
Iron, 50 × 50 × 1 mm
Response frequency *1
E Models: 500 Hz
E Models: 40 Hz
Y Models: 10 Hz
Y Models: 10 Hz
Power supply voltage *2
E Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
(operating voltage range)
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
Current consumption
E Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC
Leakage current
Y Models: Refer to Engineering Data on Data Sheet.
Control
Load current
E Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC
output
Y Models: 10 to 200 mA
Residual
E Models: 1 V max. (load current: 200 mA)
voltage
Y Models: Refer to Engineering Data on Data Sheet.
Indicators
E Models: Detection indicator (red)
Y Models: Operation indicator (red)
Operation mode (with
E1/Y1 Models: NO
sensing object approaching)
E2/Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams onData Sheet for details.
Protection circuits
E Models: Reverse polarity protection, Surge suppressor
Y Models: Surge suppressor
Ambient temperature range
Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence
E Models: ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range
Y Models: ±1% max. of sensing distance at rated voltage in rated voltage ±10% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
E Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67, in-house standards: oil-resistant
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 145 g
Approx. 170 g
Approx. 240 g
Materials
Case
Heat-resistant ABS
Sensing
surface
Accessories
E Models:
E Models:
E Models:
Mounting Bracket,
Mounting Bracket,
Mounting Bracket,
Mounting phillips screws (M4 × 25),
Mounting phillips screws (M4 × 30),
Mounting phillips screws (M5 × 40),
Instruction manual
Instruction manual
Instruction manual
Y Models:
Y Models:
Y Models:
Instruction manual
Instruction manual
Instruction manual
*1.The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2.E Models (DC switching models): A full-wave rectification power supply of 24 VDC ±10% (average value) can be used.
No comment |