No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
E2KQ-X10ME1 Chemical-resistant Proximity Sensor NEWE2KQ-X10ME1 Omron Chemical-resistant Proximity Sensor NEWProduct Description:
DC 3-Wire Model , Unshielded , M18 , Sensing Distance 6-10mm , Operation Mode NO
Specifications:
Cylinder type sensing head size
M18
Type
Unshielded
Sensing method
Capacitive type
Sensing distance
10 mm
Setting distance
6 to 10 mm
Differential distance
4% to 20% of sensing distance
Sensing object
Conductor and dielectrics
Standard sensing object
With grounded metal 50*50*1mm
Response frequency
DC: 35 Hz (average)
Power supply voltage
12 to 24 VDC (ripple(p-p) :10% Max.)
Operating voltage range
10 to 30 VDC
Current consumption
15 mA Max.
Control output (Output type)
NPN voltage-current output
Control output (Switching capacity)
0 to 100 mA
Control output (Residual voltage)
(DC) 1.5 V Max. ?under load current with cable length of 2m?
Indicator
Detection indicator(red)
Operation mode
NO
Sensitivity setting
12-turn adjustment
Protective circuit
Surge suppressor
Power supply reverse polarity protection
Standard or Different frequency
Standard
Ambient temperature
Operating: -10 to 55 CEL
Storage: -25 to 55 CEL
(with no icing or condensation)
Ambient humidity
Operating: 35 to 85 %RH
Storage: 35 to 85 %RH
(with no condensation)
Temperature influence
+-15% Max. of sensing distance in temperature range of -10 to +55CEL
(As the basis for sensing distance of 23CEL)
Voltage influence
+-2% Max. of sensing distance in rated voltage range +-20%. (As the basis for sensing distance at standard power voltage)
Insulation resistance
50 M OHM Min. at 500VDC between charged parts and the case
Dielectric strength
500 VAC 50/60 Hz for 1 minute between charged parts and the case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
500m/s2 for 3 times each in X, Y, and Z directions
Degree of protection
IEC60529: IP66
Company standard: Oil-proof
Applicable standard (EC Directive (Low Voltage Directive))
EN60947-1
EN60947-5-2
Applicable standard (EC Directive (EMC Directive))
EMI: EN60947-5-2
Emission Enclosure: CISPR11 Group 1 class A
EMS: EN60947-5-2
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Burst: IEC61000-4-4
CE marking: Equipped
Applicable standard (CCC mark)
Not equipped
Connection method
Pre-wired models (Cable length: 2 m)
Weight (Packed state)
approx. 150 g
Material (case)
Fluoride resin
Material (sensing surface)
Fluoride resin
Material (clamping nuts)
Fluoride resin
Accessories
Instruction manual, Adjustment driver