No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
E2K-F10MC1 Flat Proximity Sensor NEWE2K-F10MC1 Omron Flat Proximity Sensor NEWProduct Description:
DC 3-Wire Model , Flat Type , Unshielded , Sensing Distance 10mm , Operation Mode NO.
Specifications:
Type
Unshielded
Sensing method
Capacitive type
Sensing distance
10 mm -10% to +10%
Setting distance
0 to 7.5 mm
Differential distance
15% Max. of sensing distance
Sensing object
Conductor and dielectrics
Standard sensing object
With grounded metal 50*50*1mm
Response frequency
DC: 100 Hz (average)
Power supply voltage
12 to 24 VDC (ripple(p-p) :10% Max.)
Operating voltage range
10 to 30 VDC
Current consumption
10 mA Max. (at 24VDC)
Control output (Output type)
NPN open collector output
Control output (Switching capacity)
0 to 100 mA (at 30VDC)
Control output (Residual voltage)
(DC) 1.5 V Max. ?under load current with cable length of 2m?
Indicator
Detection indicator(red)
Operation mode
NO
Protective circuit
Surge suppressor
Power supply reverse polarity protection
Standard or Different frequency
Standard
Ambient temperature
Operating: -10 to 55 CEL
Storage: -10 to 55 CEL
(with no icing or condensation)
Ambient humidity
Operating: 35 to 95 %RH
Storage: 35 to 95 %RH
(with no condensation)
Temperature influence
+-15% Max. of sensing distance in temperature range of -10 to +55CEL
(As the basis for sensing distance of 23CEL)
Voltage influence
+-2.5% Max. of sensing distance in rated voltage range +-10%. (As the basis for sensing distance at standard power voltage)
Insulation resistance
50 M OHM Min. at 500VDC between charged parts and the case
Dielectric strength
500 VAC 50/60 Hz for 1 minute between charged parts and the case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
500m/s2 for 3 times each in X, Y, and Z directions
Degree of protection
IEC60529: IP66
Applicable standard (EC Directive (Low Voltage Directive))
EN60947-1
EN60947-5-2
Applicable standard (EC Directive (EMC Directive))
EMI: EN60947-5-2
Emission Enclosure: CISPR11 Group 1 class A
EMS: EN60947-5-2
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Burst: IEC61000-4-4
CE marking: Equipped
Applicable standard (CCC mark)
Not equipped
Connection method
Pre-wired models (Cable length: 2 m)
Weight (Packed state)
approx. 35 g
Material (case)
Heat-resistant ABS resin
Material (sensing surface)
Heat-resistant ABS resin
Accessories
Instruction manual
No comment |