Your Position: Home > Control System > PLC > Siemens PLC > 6ES7313-6CE00-0AB0 SIEMENS CPU Module New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

6ES7313-6CE00-0AB0 SIEMENS CPU Module New

prevnext

6ES7313-6CE00-0AB0 SIEMENS CPU Module New
  • Market price: $ 3933.6
  • Shop price: $ 1192.0
  • Goods click count: 256
  • Total:
  • Quantity:
Add to cart collect
  

Description

6ES7313-6CE00-0AB0 SIEMENS CPU Module New

SIEMENS CPU Module 6ES7313-6CE00-0AB0

Product Description:

SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 32 KBYTE WORKING MEMORY, MICRO MEMORY CARD REQUIRED.

Features:

Supply voltage

24 V DC

Yes

permissible range, lower limit (DC)

20.4 V

permissible range, upper limit (DC)

28.8 V

Load voltage L+

Rated value (DC)

24 V

permissible range, lower limit (DC)

20.4 V

permissible range, upper limit (DC)

28.8 V

Input current

Inrush current, max.

11 A

from supply voltage L+, max.

900 mA

Power losses

Power loss, typ.

10 W

Memory

Work memory

integrated

32 kbyte; For program and data

expandable

No

Load memory

expandable FEPROM

Yes; with Micro Memory Card (MMC)

expandable FEPROM, max.

4 Mbyte

Backup

present

Yes; Guaranteed by MMC (maintenance-free)

without battery

Yes; Program and data

CPU processing times

for bit operations, min.

0.1 µs

for bit operations, max.

0.2 µs

for word operations, min.

0.5 µs

for fixed point arithmetic, min.

1 µs

for floating point arithmetic, min.

15 µs

CPU-blocks

DB

Number, max.

127; DB 0 reserved

Size, max.

16 kbyte

FB

Number, max.

128

Size, max.

16 kbyte

FC

Number, max.

128

Size, max.

16 kbyte

OB

Size, max.

16 kbyte

Number of time alarm OBs

1

Number of delay alarm OBs

1

Number of time interrupt OBs

1

Number of process alarm OBs

1

Nesting depth

per priority class

8

additional within an error OB

4

Counters, timers and their retentivity

S7 counter

Number

256

of which retentive without battery

adjustable

Yes

lower limit

0

upper limit

256

Counting range

lower limit

1

upper limit

999

IEC counter

present

Yes

Type

SFB

S7 times

Number

256

Retentivity

adjustable

Yes

lower limit

0

upper limit

256

Time range

lower limit

10 ms

upper limit

9990 s

IEC timer

present

Yes

Type

SFB

Data areas and their retentivity

Flag

Number, max.

256 byte

Retentivity available

Yes; MB 0 to MB 255

Address area

I/O address area

Inputs

1 kbyte

Outputs

1 kbyte

Process image

Inputs

128 byte

Outputs

128 byte

Digital channels

Inputs

992

Outputs

992

Analog channels

Inputs

248

Outputs

124

Hardware configuration

Modules per rack, max.

31

Expansion devices, max.

3

Number of DP masters

integrated

1

via CP

1

Number of operable FMs and CPs (recommended)

FM

8

CP, point-to-point

4

CP, LAN

2

Time of day

Clock

Hardware clock (real-time clock)

Yes

battery-backed and synchronizable

Yes

Operating hours counter

Number

1

Clock synchronization

supported

Yes

Digital inputs

Number/binary inputs

16

Input voltage

Rated value, DC

24 V

for signal "0"

-3 to +5 V

for signal "1"

15 to 30 V

Input current

for signal "1", typ.

8 mA; Min. 2 mA

Input delay (for rated value of input voltage)

for standard inputs

Parameterizable

Yes; 0.1 / 0.3 / 3 / 15 ms

for counter/technological functions

at "0" to "1", max.

8 µs

Cable length

Cable length, shielded, max.

1000 m; 100 m for technological functions

Cable length unshielded, max.

600 m

Digital outputs

Number/binary outputs

16

Functionality/short-circuit strength

Yes; Clocked electronically

Limitation of inductive shutdown voltage to

L+ (-48 V)

Output voltage

for signal "1", min.

L+ (-0.8 V)

Output current

for signal "1" permissible range for 0 to 40 °C, max.

500 mA

for signal "1" permissible range for 0 to 60 °C, max.

500 mA

for signal "1" minimum load current

5 mA

for signal "0" residual current, max.

0.5 mA

Switching frequency

with resistive load, max.

100 Hz

with inductive load, max.

0.5 Hz

Aggregate current of outputs (per group)

all mounting positions

up to 40 °C, max.

8 A

up to 60 °C, max.

4 A

Cable length

Cable length, shielded, max.

1000 m

Cable length unshielded, max.

600 m

Encoder

Connectable encoders

2-wire sensor

Yes

Permissible quiescent current (2-wire sensor), max.

1.5 mA

Interfaces

MPI

Cable length, max.

50 m; without repeater

1st interface

Isolated

No

Functionality

MPI

Yes

DP master

No

DP slave

No

MPI

Number of connections

8

Services

PG/OP communication

Yes

Global data communication

Yes

S7 basic communication

Yes

S7 communication

Yes

S7 communication, as client

No

S7 communication, as server

Yes

Transmission rate, max.

187.5 kbit/s

DP master

Number of connections, max.

8; For PG/OP communication

Services

PG/OP communication

Yes

Global data communication

No

S7 basic communication

No

S7 communication, as client

No

S7 communication, as server

No

Equidistance mode support

Yes

SYNC/FREEZE

Yes

Direct data exchange (slave-to-slave communication)

Yes

Transmission rate, max.

12 kbit/s

Number of DP slaves, max.

32

Address area

Inputs, max.

1 kbyte

Outputs, max.

1 kbyte

User data per DP slave

User data per DP slave, max.

244 byte

2nd interface

Isolated

Yes

Functionality

MPI

No

DP master

Yes

DP slave

Yes

Local Operating Network

No

DP master

Number of connections, max.

8; For PG/OP communication

Services

PG/OP communication

Yes

Global data communication

No

S7 basic communication

No

S7 communication

No

S7 communication, as client

No

S7 communication, as server

No

Equidistance mode support

Yes

SYNC/FREEZE

Yes

Direct data exchange (slave-to-slave communication)

Yes

Transmission rate, max.

12 Mbit/s

Number of DP slaves, max.

32

Address area

Address area, max.

1024 byte; 1 KB/1 KB

User data per DP slave

User data per DP slave, max.

244 byte; 244 bytes/244 bytes

Communication functions

PG/OP communication

Yes

Global data communication

supported

Yes

Number of GD packets, transmitter, max.

4

Number of GD packets, receiver, max.

4

Size of GD packets, max.

22 byte

S7 basic communication

supported

Yes

User data per job, max.

76 byte

S7 communication

supported

Yes

as server

Yes

as client

No

User data per job, max.

64 kbyte

Number of connections

overall

8

usable for PG communication

7

reserved for PG communication

1

Adjustable for PG communication, max.

7

usable for OP communication

7

reserved for OP communication

1

adjustable for OP communication, max.

7

usable for S7 basic communication

4

Reserved for S7 basic communication

4

adjustable for S7 basic communication, max.

4

usable for routing

4

S7 message functions

Number of login stations for message functions, max.

5

Integrated Functions

Number of counters

3

Counter frequency (counter) max.

30 kHz

Frequency measurement

Yes

PID controller

Yes

Number of pulse outputs

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: