6ES7313-6CE00-0AB0 SIEMENS CPU Module New6ES7313-6CE00-0AB0 SIEMENS CPU Module NewSIEMENS CPU Module 6ES7313-6CE00-0AB0
Product Description:
SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 32 KBYTE WORKING MEMORY, MICRO MEMORY CARD REQUIRED.
Features:
Supply voltage
24 V DC
Yes
permissible range, lower limit (DC)
20.4 V
permissible range, upper limit (DC)
28.8 V
Load voltage L+
Rated value (DC)
24 V
permissible range, lower limit (DC)
20.4 V
permissible range, upper limit (DC)
28.8 V
Input current
Inrush current, max.
11 A
from supply voltage L+, max.
900 mA
Power losses
Power loss, typ.
10 W
Memory
Work memory
integrated
32 kbyte; For program and data
expandable
No
Load memory
expandable FEPROM
Yes; with Micro Memory Card (MMC)
expandable FEPROM, max.
4 Mbyte
Backup
present
Yes; Guaranteed by MMC (maintenance-free)
without battery
Yes; Program and data
CPU processing times
for bit operations, min.
0.1 µs
for bit operations, max.
0.2 µs
for word operations, min.
0.5 µs
for fixed point arithmetic, min.
1 µs
for floating point arithmetic, min.
15 µs
CPU-blocks
DB
Number, max.
127; DB 0 reserved
Size, max.
16 kbyte
FB
Number, max.
128
Size, max.
16 kbyte
FC
Number, max.
128
Size, max.
16 kbyte
OB
Size, max.
16 kbyte
Number of time alarm OBs
1
Number of delay alarm OBs
1
Number of time interrupt OBs
1
Number of process alarm OBs
1
Nesting depth
per priority class
8
additional within an error OB
4
Counters, timers and their retentivity
S7 counter
Number
256
of which retentive without battery
adjustable
Yes
lower limit
0
upper limit
256
Counting range
lower limit
1
upper limit
999
IEC counter
present
Yes
Type
SFB
S7 times
Number
256
Retentivity
adjustable
Yes
lower limit
0
upper limit
256
Time range
lower limit
10 ms
upper limit
9990 s
IEC timer
present
Yes
Type
SFB
Data areas and their retentivity
Flag
Number, max.
256 byte
Retentivity available
Yes; MB 0 to MB 255
Address area
I/O address area
Inputs
1 kbyte
Outputs
1 kbyte
Process image
Inputs
128 byte
Outputs
128 byte
Digital channels
Inputs
992
Outputs
992
Analog channels
Inputs
248
Outputs
124
Hardware configuration
Modules per rack, max.
31
Expansion devices, max.
3
Number of DP masters
integrated
1
via CP
1
Number of operable FMs and CPs (recommended)
FM
8
CP, point-to-point
4
CP, LAN
2
Time of day
Clock
Hardware clock (real-time clock)
Yes
battery-backed and synchronizable
Yes
Operating hours counter
Number
1
Clock synchronization
supported
Yes
Digital inputs
Number/binary inputs
16
Input voltage
Rated value, DC
24 V
for signal "0"
-3 to +5 V
for signal "1"
15 to 30 V
Input current
for signal "1", typ.
8 mA; Min. 2 mA
Input delay (for rated value of input voltage)
for standard inputs
Parameterizable
Yes; 0.1 / 0.3 / 3 / 15 ms
for counter/technological functions
at "0" to "1", max.
8 µs
Cable length
Cable length, shielded, max.
1000 m; 100 m for technological functions
Cable length unshielded, max.
600 m
Digital outputs
Number/binary outputs
16
Functionality/short-circuit strength
Yes; Clocked electronically
Limitation of inductive shutdown voltage to
L+ (-48 V)
Output voltage
for signal "1", min.
L+ (-0.8 V)
Output current
for signal "1" permissible range for 0 to 40 °C, max.
500 mA
for signal "1" permissible range for 0 to 60 °C, max.
500 mA
for signal "1" minimum load current
5 mA
for signal "0" residual current, max.
0.5 mA
Switching frequency
with resistive load, max.
100 Hz
with inductive load, max.
0.5 Hz
Aggregate current of outputs (per group)
all mounting positions
up to 40 °C, max.
8 A
up to 60 °C, max.
4 A
Cable length
Cable length, shielded, max.
1000 m
Cable length unshielded, max.
600 m
Encoder
Connectable encoders
2-wire sensor
Yes
Permissible quiescent current (2-wire sensor), max.
1.5 mA
Interfaces
MPI
Cable length, max.
50 m; without repeater
1st interface
Isolated
No
Functionality
MPI
Yes
DP master
No
DP slave
No
MPI
Number of connections
8
Services
PG/OP communication
Yes
Global data communication
Yes
S7 basic communication
Yes
S7 communication
Yes
S7 communication, as client
No
S7 communication, as server
Yes
Transmission rate, max.
187.5 kbit/s
DP master
Number of connections, max.
8; For PG/OP communication
Services
PG/OP communication
Yes
Global data communication
No
S7 basic communication
No
S7 communication, as client
No
S7 communication, as server
No
Equidistance mode support
Yes
SYNC/FREEZE
Yes
Direct data exchange (slave-to-slave communication)
Yes
Transmission rate, max.
12 kbit/s
Number of DP slaves, max.
32
Address area
Inputs, max.
1 kbyte
Outputs, max.
1 kbyte
User data per DP slave
User data per DP slave, max.
244 byte
2nd interface
Isolated
Yes
Functionality
MPI
No
DP master
Yes
DP slave
Yes
Local Operating Network
No
DP master
Number of connections, max.
8; For PG/OP communication
Services
PG/OP communication
Yes
Global data communication
No
S7 basic communication
No
S7 communication
No
S7 communication, as client
No
S7 communication, as server
No
Equidistance mode support
Yes
SYNC/FREEZE
Yes
Direct data exchange (slave-to-slave communication)
Yes
Transmission rate, max.
12 Mbit/s
Number of DP slaves, max.
32
Address area
Address area, max.
1024 byte; 1 KB/1 KB
User data per DP slave
User data per DP slave, max.
244 byte; 244 bytes/244 bytes
Communication functions
PG/OP communication
Yes
Global data communication
supported
Yes
Number of GD packets, transmitter, max.
4
Number of GD packets, receiver, max.
4
Size of GD packets, max.
22 byte
S7 basic communication
supported
Yes
User data per job, max.
76 byte
S7 communication
supported
Yes
as server
Yes
as client
No
User data per job, max.
64 kbyte
Number of connections
overall
8
usable for PG communication
7
reserved for PG communication
1
Adjustable for PG communication, max.
7
usable for OP communication
7
reserved for OP communication
1
adjustable for OP communication, max.
7
usable for S7 basic communication
4
Reserved for S7 basic communication
4
adjustable for S7 basic communication, max.
4
usable for routing
4
S7 message functions
Number of login stations for message functions, max.
5
Integrated Functions
Number of counters
3
Counter frequency (counter) max.
30 kHz
Frequency measurement
Yes
PID controller
Yes
Number of pulse outputs