Your Position: Home > Low Voltage > Others Electrical > FS-N11N KEYENCE Fiber amplifier NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

FS-N11N KEYENCE Fiber amplifier NEW

prevnext

FS-N11N KEYENCE Fiber amplifier NEW
  • Market price: $ 488.4
  • Shop price: $ 148.0
  • Goods click count: 348
  • Total:
  • Quantity:
Add to cart collect
  

Description

FS-N11N KEYENCE Fiber amplifier NEW

Product Description:

Latest waterproof fiber optic sensor amplifier

IP66 standard is only one key to complete the set (new concept)

Automatic maintenance (new concept)

High-power to reduce the artificial time

The world's largest power beam, 250 times the brightness

The world's highest level of accuracy can be detected only ø0.6 μm diameter wire

The world's most lightfastness, 30,000 lux

Specifications:

 

Type

NEW IP66 Fiberoptic Amplifer, 1 output type

Cable/M8 connector

M8 connector *1

Main unit/expansion unit

Main unit

Model

NPN

FS-N15CN

PNP

FS-N15CP

Control output

1 output

Monitor output (1-5V)

External input

1 input

Light source LED

Red 4-element LED (wavelength 630 nm)

Response time

50 μs (HIGH SPEED)/250 μs(FINE)/500 μs(TURBO)/ 1 ms (SUPER) /4 ms (ULTRA)/16 ms (MEGA)

Output toggle

Light-ON/Dark-ON toggle

Timer function

Timer OFF/OFF delay/ON delay/One-shot

Control output

NPN output

NPN open collector 24 V or less; maximum 100 mA or less, residual voltage 1 V or less

PNP output

PNP open collector 24 V or less; maximum 100 mA or less, residual voltage 1 V or less

External input

Input time 2 ms (ON)/20 ms (OFF) or more, when selecting External calibration 25 ms (ON/OFF) or more

Expansion units

0 units (expansion not possible)

Protection circuit

Protection against reverse power connection, Output overcurrent, and Output surge

Number of interference prevention units

0 units (connection not possible)

Rating

Power voltage

12 to 24 V DC ± 10% ripple (P-P) 10% or less

NPN

Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V) *2
Econ on (ALL): 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V) *2
Eco full: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)

PNP

Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V) *2
Eco on (ALL): 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V) *2
Eco full: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)

Environmental
resistance

Operating ambient luminance

Incandescent lamp: 20,000 lux or less, sunlight: 30,000 lux or less

Operating ambient temperature

-20°C to +55°C -4°F to 131°F (no freezing)

Operating ambient humidity

35 to 85%RH (no condensation)

Vibration resistance

10 to 55 Hz compound amplitude 1.5 mm 0.06", 2 hours for each of X, Y, Z axis

Shock resistance

500 m/s2, 3 times for each of X, Y, Z axis

Enclosure rating

IP66 *3*4

Material

Case

Main unit: glass-reinforced PBT; Cover: Sulfonic resin

Adapter

Glass-reinforced PBT

Case Dimensions

H 31.0 mm × W 13.0 mm × L 94.0 mm H 1.22" x W 0.51" x L 3.70"

Weight

App. 30g

     

Note:

*1 Use a cable of 30 m 98.43' or less.

*2 When the Power Mode is set to HIGH SPEED, 100 mW (4.0 mA) will be added.

*3 About the enclosure rating when a small-diameter fiber unit (the diameter of the cable is ø1.3 or ø1.0) is used.

IP66/IP65 cannot be satisfied when the type whose diameter is ø1.3 and terminal can be separated (FU-4F/ 66/91/93/43/63/63T etc.) is used.

When any small-diameter fiber units except for the above are used, IP65 is applied.

*4 In any of the following cases, the enclosure rating IP66/IP65 cannot be satisfied.

• When the Fiber Unit and KEYENCE’s M8 connector cable are not connected (Recommended conditions to tighten up the M8 connector: Tighten it by hand first.

Then retighten it as much as 1/16-1/8 of a rotation with pliers.)

• When the Fiber Unit and KEYENCE’s M8 connector cable are not connected

• When the dust cover of the Sensor Amplifier is open

• When there is debris in the dust cover

• When the waterproof adapter A/B are not used at the time of installation of a small-diameter fiber unit.






  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: