H3CR-H8L AC220V S OMRON Time Relay NEW

OMRON Time Relay H3CR-H8L AC220V S            

Product Description:

Long power OFF-delay times;

S-series: up to 12 seconds,

M-series: up to 12 minutes.

Models with forced-reset input are available.

11-pin and 8-pin models are available.

Specifications:

Accuracy of operating time

±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 0.6 and 1.2 s)

Setting error

±5% FS ±50 ms max.

Operation start voltage

30% max. of rated voltage

Influence of voltage

±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 0.6 and 1.2 s)

Influence of temperature

±1% FS max. (±1% FS ±10 ms max. in ranges of 0.6 and 1.2 s)

Insulation resistance

100 MΩ min. (at 500 VDC)

Dielectric strength

2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)

2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)

2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)

1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)

Impulse withstand

3 kV (between power terminals) for 100 to 120 VAC, 200 to 240 VAC, 100 to 125 VDC;

voltage

1 kV for 24 VAC/DC, 48 VDC

 

4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 120 VAC, 200 to 240 VAC, 100 to 125 VDC;

 

1.5 kV for 24 VAC/DC, 48 VDC

Noise immunity

±1.5 kV (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator

(pulse width: 100 ns/1 μs, 1-ns rise); ±1 kV (between power terminals) for 48 VDC

Static immunity

Malfunction: 8 kV, Destruction: 15 kV

Vibration resistance

Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions

Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions

Shock resistance

Destruction: 980 m/s2 three times each in six directions

Malfunction: 98 m/s2 three times each in six directions

Ambient temperature

Operating: -10°C to 55°C (with no icing),

Storage: -25°C to 65°C (with no icing)

Ambient humidity

Operating: 35% to 85%

Life expectancy

Mechanical: 10 million operations min. (under no load at 1,200 operations/h)

Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h) (See note)

EMC

(EMI) EN61812-1

Emission Enclosure: EN55011 Group 1 class A

Emission AC Mains: EN55011 Group 1 class A

(EMS) EN61812-1

Immunity ESD: IEC61000-4-2: 6 kV contact discharge (level 3)

8 kV air discharge (level 3)

Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)

Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3)

Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0.15 to 80 MHz) (level 3)

Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3)

2 kV I/O signal-line (level 4)

Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3)

2 kV line to ground (level 3)

Case color

Light Gray (Munsell 5Y7/1)

Degree of protection

IP40 (panel surface)

Weight

Approx. 120 g

 

 

  