No comment |
PTF08A-E OMRON RELAY NewProduct Description?
?Equipped with arc barrier.
Dielectric strength: 2,000 V.
Built-in diode models added to the LY Series.
Single-pole and double-pole models are applicable to operating coils with ratings of 100 ⁄ 110 VAC, 110 ⁄ 120 VAC, 200 ⁄ 220 VAC, 220 ⁄ 240 VAC, or 100 ⁄ 110 VDC.
Three-pole and four-pole models are applicable to operating coils with ratings of 100 ⁄ 110 VAC, 200 ⁄ 220 VAC, or 100 ⁄ 110 VDC.
Specifications:
Coil Rating
Single- and Double-pole Relays
Rated
voltageRated current
Coil
ResistanceCoil Induction
(reference value)Must
operate
voltageMust
release
voltageMax.
voltagePower
Consumption
(approx.)50 Hz
60 Hz
Arm. OFF
Arm. ON
% of rated voltage
AC
6 V
214.1 mA
183 mA
12.2 Ω
0.04 H
0.08 H
80% max.
80% max.
110%
1.0 to
1.2 VA
(60 Hz)12 V
106.5 mA
91 mA
46 Ω
0.17 H
0.33 H
24 V
53.8 mA
46 mA
180Ω
0.69 H
1.30 H
50 V
25.7 mA
22 mA
788ΩW
3.22 H
5.66 H
100/
110 V11.7/
12.9 mA10/
11 mA3,750 Ω
14.54 H
24.6 H
0.9 to 1 VA
(60 Hz)110/
120 V9.9/
10.8 mA8.4/
9.2 mA4,430 Ω
19.20 H
32.1 H
200/
220 V6.2/
6.8 mA5.3/
5.8 mA12,950 Ω
54.75 H
94.07 H
220/
240 V4.8/
5.3 mA4.2/
4.6 mA18,790 Ω
83.50 H
136.40 H
DC
6 V
150 mA
40 Ω
0.16 H
0.33 H
10% min.
0.9 W
12 V
75 mA
160 Ω
0.73 H
1.37 H
24 V
36.9 mA
650 Ω
3.20 H
5.72 H
48 V
18.5 mA
2,600 Ω
10.6 H
21.0 H
100/
110 V9.1/
10 mA11,000 Ω
45.6 H
86.2 H
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15% ⁄ -20% for rated currents and ±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required.
No comment |