Product Description?
Easy to mount, wire, and use.
A large selection of models including various contact forms,DC-switching models, and open models.
Mechanical life: 5,000,000 operations; electrical life (under rated load): 500,000 operations.
Models also available with built-in diodes and for use as auxiliary power relays.
Specifications:
Open Coils (with Solder or Screw Terminals)
Rated voltage | Rated current (mA) | Coil resistance (Ω) | Must- | Must- | Max. | Power consumption | ||||||
DP | 3P or 4P | DP | 3P or 4P | |||||||||
50 Hz | 60 Hz | 50 Hz | 60 Hz | % of rated voltage | Initial | Rated | ||||||
AC | 6 | 790 | 655 | 1,120 | 950 | 1.1 | 0.5 | 80% max. | 30% min. | 110% | Approx. | Approx. |
12 | 395 | 325 | 560 | 480 | 4.7 | 2.0 | ||||||
24 | 195 | 160 | 280 | 240 | 19 | 8.5 | ||||||
50 | 94 | 78 | 134 | 114 | 82 | 36 | ||||||
100/(110) | 47 | 39/45 | 67 | 57/66 | 340 | 150 | ||||||
200/(220) | 23.5 | 19.5/ 22.5 | 33.5 | 28.5/33 | 1,540 | 620 | ||||||
DC | 6 | 340 | 450 | 17.5 | 13.4 | 70% max. | 10% min. | Approx. 2.1 (DP) | ||||
12 | 176 | 220 | 68 | 54 | ||||||||
24 | 87 | 94 | 275 | 255 | ||||||||
48 | 41 | 52 | 1,180 | 930 | ||||||||
100/110 | 17/19 | 22/24.5 | 5,750 | 4,500 | ||||||||
200/220 | 8.6/9.5 | 11/12 | 23,200 | 18,000 |
Note:
1.The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and ±15% for DC coil resistance.
2.The AC coil resistance values are reference values.
3.Performance characteristic data are measured at a coil temperature of 23°C.
4.The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.
MM4P AC100 OMRON RELAY NewProduct Description?
Easy to mount, wire, and use.
A large selection of models including various contact forms,DC-switching models, and open models.
Mechanical life: 5,000,000 operations; electrical life (under rated load): 500,000 operations.
Models also available with built-in diodes and for use as auxiliary power relays.
Specifications:
Open Coils (with Solder or Screw Terminals)
Rated voltage
(V)Rated current (mA)
Coil resistance (Ω)
Must-
operate
voltageMust-
release
voltageMax.
voltagePower consumption
(VA or W)DP
3P or 4P
DP
3P or 4P
50 Hz
60 Hz
50 Hz
60 Hz
% of rated voltage
Initial
Rated
AC
6
790
655
1,120
950
1.1
0.5
80% max.
30% min.
(60 Hz)
25% min.
(50 Hz)110%
Approx.
4.1 (DP)
Approx.
6.3 (3P or
4P)Approx.
3.5 (DP)
Approx.
5.1 (3P or
4P)12
395
325
560
480
4.7
2.0
24
195
160
280
240
19
8.5
50
94
78
134
114
82
36
100/(110)
47
39/45
67
57/66
340
150
200/(220)
23.5
19.5/ 22.5
33.5
28.5/33
1,540
620
DC
6
340
450
17.5
13.4
70% max.
10% min.
Approx. 2.1 (DP)
Approx. 2.7 (3P or 4P)12
176
220
68
54
24
87
94
275
255
48
41
52
1,180
930
100/110
17/19
22/24.5
5,750
4,500
200/220
8.6/9.5
11/12
23,200
18,000
Note:
1.The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and ±15% for DC coil resistance.
2.The AC coil resistance values are reference values.
3.Performance characteristic data are measured at a coil temperature of 23°C.
4.The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.