No comment |
MM2KP OMRON RELAY NewProduct Description?
Ratings
Product classification
Bistable relays
Standard typeCoil ratings
Operate 24 VAC 170 mA (50 Hz), 24 VAC 145 mA (60 Hz)
Release 24 VAC 191 mA (50 Hz), 24 VAC 170 mA (60 Hz)Coil resistance
Operate: 19 Ohm
Release: 35 OhmOperate voltage (Set voltage)
80% Max.
Release voltage (Reset voltage)
(50 Hz), (60 Hz)
80% Max.Max. voltage
110% (of rated voltage)
Power consumption (Latching (Operate))
6.2 VA (60 Hz)
3.5 VA (60 Hz)Power consumption (Latching (Release))
6.5 VA (60 Hz)
4.1 VA (60 Hz)Operating indicator
Not equipped
Coil surge killer
Not equipped
Contact Type
DPDT
Contact method
Single
Contact material
Contact body material: Ag
Contact finish: NothingContact rated load
220 VAC 5 A (Resistive load)
220 VAC 5 A (Inductive load (cos phi = 0.4))
24 VDC 4 A (Resistive load)
24 VDC 4 A (Inductive load (L/R = 7 ms))Maximum switching voltage
250 VAC (Resistive load)
250 VAC (Inductive load (cos phi = 0.4))
250 VDC (Resistive load)
250 VDC (Inductive load (L/R = 7 ms))Maximum switching current
AC: 5 A (Resistive load)
AC: 5 A (Inductive load (cos phi = 0.4))
DC: 5 A (Resistive load)
DC: 5 A (Inductive load (L/R = 7 ms))Maximum switching power
AC: 1100 VA (Resistive load)
AC: 1100 VA (Inductive load (cos phi = 0.4))
DC: 96 W (Resistive load)
DC: 96 W (Inductive load (L/R = 7 ms))Failure rate
10 mA at 5 VDC (failure level: P Reference value)
Ambient temperature
Operating: -10 to 55 CEL
(with no icing or condensation)Ambient humidity
Operating: 5 to 85% RH
(with no icing or condensation)Characteristics
Contact resistance
Max. 50 mOhm, Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
Operating time (set time)
30 ms Max.
Release time (Reset time)
30 ms Max.
Min.set-reset signal width
100 ms Min.
Max.operating frequency (Mechanical)
1800 opn./h
Max.operating frequency (Erectrical)
1800 opn./h
Insulation resistance
Between coil and contacts: 100 MOhm Min. (at 500 VDC)
Between contacts of different polarity: 100 MOhm Min. (at 500 VDC)
Between contacts of same polarity: 100 MOhm Min. (at 500 VDC)
Between set and reset coils: 100 MOhm Min. (at 500 VDC)
Between current-carrying metal parts and ground terminal: 100 MOhm Min. (at 500 VDC)Dielectric strength
Between coil and contacts: 2000 VAC 50/60 Hz for 1 min (Leakage current 10 mA 50/60 Hz 1 min)
Between contacts of different polarity: 2000 VAC 50/60 Hz for 1 min (Leakage current 10 mA 50/60 Hz 1 min)
Between contacts of same polarity: 1500 VAC 50/60 Hz for 1 min (Leakage current 10 mA 50/60 Hz 1 min)
Between set and reset coils: 2000 VAC 50/60 Hz for 1 min (Leakage current 10 mA 50/60 Hz 1 min)
Between current-carrying metal parts and ground terminal: 2000 VAC 50/60 Hz for 1 min (Leakage current 10 mA 50/60 Hz 1 min)Vibration resistance (Destruction)
10 to 55 to 10 Hz 0.375-mm single amplitude (0.75-mm double amplitude) for 2 hours each in X, Y, and Z directions (No defect in appearance and construction after applying variable vibration in each directions for 2 hours.)
Vibration resistance (Malfunction)
10 to 35 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) in each direction
Shock resistance (Destruction)
500 m/s**2 each direction 3 times
Shock resistance (Malfunction)
50 m/s**2
Endurance (Mechanical)
2500000 operations Min.
Endurance (Electrical)
500000 operations Min.
Protective structure
Closed type (cover)
Terminal structure
Plug-in
Weight
Approx. 375 g
No comment |