Your Position: Home > Low Voltage > Relay > H3Y2 RELAY New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

H3Y2 RELAY New

prevnext

H3Y2  RELAY  New
  • NO.: H3Y2
  • Weight: 50gram
  • Market price: $ 16.5
  • Shop price: $ 5.0
  • Goods click count: 394
  • Total:
  • Quantity:
Add to cart collect
  

Description

H3Y2 OMRON RELAY New

Product Description?

Semi-multi power supply voltage.

Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver can also be used for time setting.

Pin configuration compatible with MY Power Relay.

LED indication for power and output statuses.

Conforms to EMC standards.

Conforms to EN61812-1 and approved by UL and CSA.

Specifications:

Time Ranges

Rated time

Time setting range

Rated time

Time setting range

0.5 s

0.04 to 0.5 s

3 min

0.1 to 3 min

1 s

0.1 to 1 s

5 min

0.2 to 5 min

5 s

0.2 to 5 s

10 min

0.5 to 10 min

10 s

0.5 to 10 s

30 min

1 to 30 min

30 s

1.0 to 30 s

60 min

2 to 60 min

60 s

2.0 to 60 s

3 h

0.1 to 3 h

120 s

5.0 to 120 s

---

---

Ratings

Item

H3Y-2(-0)/H3Y-4(-0)

Rated supply voltage

24, 100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz) (See note 1.),
12, 24, 48, 125, 100 to 110 VDC (See notes 2 and 3.)

Operating voltage range

All rated voltages except 12 VDC: 85% to 110% of rated supply voltage
12 VDC: 90% to 110% of rated supply voltage (See note 4.)

Reset voltage

10% min. of rated supply voltage (See note 5.)

Power consumption

100 to 120 VAC:
Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz
Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz
200 to 230 VAC:
Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz
Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz
24 VAC:
Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz
Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz
12 VDC:
Relay ON: Approx. 1.1 W at 12 VDC
Relay OFF: Approx. 0.1 W at 12 VDC
24 VDC:
Relay ON: Approx. 1.1 W at 24 VDC
Relay OFF: Approx. 0.1 W at 24 VDC
48 VDC:
Relay ON: Approx. 1.2 W at 48 VDC
Relay OFF: Approx. 0.3 W at 48 VDC
100 to 110 VDC:
Relay ON: Approx. 1.6 W at 110 VDC
Relay OFF: Approx. 0.4 W at 110 VDC
125 VDC:
Relay ON: Approx. 1.6 W at 125 VDC
Relay OFF: Approx. 0.4 W at 125 VDC

Control outputs

H3Y-2(-0): 5 A at 250 VAC, resistive load (cosΦ = 1)
H3Y-4(-0): 3 A at 250 VAC, resistive load (cosΦ = 1)

Note:

1.Do not use the output from an inverter as the power supply.

2.With DC ratings, single-phase full-wave rectified power sources may be used.

3.Only the H3Y-2 and H3Y-2-0 Series include 2-VDC models.

4.Use the Timer within 90% to 110% of the rated supply voltage (95% to 110% for 12 VDC) when using it continuously under an ambient operating temperature of 50°C.

5.Set the reset voltage as follows to ensure proper resetting.
100 to 120 VAC:10 VAC max.
200 to 230 VAC:20 VAC max.
100 to 110 VDC:10 VDC max.

Characteristics

Accuracy of operating time

±1% FS max. (0.5 s range: ±1%±10 ms max.)

Setting error
(see note 1)

±10%±50 ms FS max.

Reset time

Min. power-opening time: 0.1 s max. (including halfway reset)

Reset voltage

10% max. of rated supply voltage

Influence of voltage
(see note 1)

±2% FS max.

Influence of temperature
(see note 1)

±2% FS max.

Insulation resistance

100 MΩ min. (at 500 VDC)

Dielectric strength

2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts)
(see note 2)
2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output)
(see note 2)
2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model)
(see note 2)
1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)

Vibration resistance

Destruction: 10 to 55 Hz, 0.75-mm single amplitude
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude

Shock resistance

Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)

Ambient temperature

Operating: -10°C to 50°C (with no icing)
Storage: -25°C to 65°C (with no icing)

Ambient humidity

Operating: 35% to 85%

Life expectancy

Mechanical:10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
H3Y-2: 500,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h)
H3Y-4: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h)

Impulse withstand voltage

Between power terminals:
3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1 kV for 12 VDC, 24 VDC, 48 VDC
Between exposed non-current-carrying metal parts:
4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1.5 kV for 12 VDC, 24 VDC, 48 VDC

Noise immunity

±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)

Static immunity

Destruction: 8 kV
Malfunction: 4 Kv

Enclosure rating

IP40

Weight

Approx. 50 g

EMC

(EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5: 2 kV line to ground (level 3)
1 kV line to line (level 3)

Approved standards

UL508, CSA C22.2 No. 14, Lloyds
Conforms to EN61812-1 and IEC60664-1.
(2.5 kV/2 for H3Y-2/-2-0, 2.5 kV/1 for H3Y-4/-4-0)
Output category according to EN60947-5-1.

Note:

1.Add ±10 ms to the above value for the 0.5 s range model.

2.Terminal screw sections are excluded.

Caution: In the interest of product improvement, specifications are subject to change without notice.





















  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: