No comment |
H3Y2 OMRON RELAY NewProduct Description?
Semi-multi power supply voltage.
Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver can also be used for time setting.
Pin configuration compatible with MY Power Relay.
LED indication for power and output statuses.
Conforms to EMC standards.
Conforms to EN61812-1 and approved by UL and CSA.
Specifications:
Time Ranges
Rated time
Time setting range
Rated time
Time setting range
0.5 s
0.04 to 0.5 s
3 min
0.1 to 3 min
1 s
0.1 to 1 s
5 min
0.2 to 5 min
5 s
0.2 to 5 s
10 min
0.5 to 10 min
10 s
0.5 to 10 s
30 min
1 to 30 min
30 s
1.0 to 30 s
60 min
2 to 60 min
60 s
2.0 to 60 s
3 h
0.1 to 3 h
120 s
5.0 to 120 s
---
---
Ratings
Item
H3Y-2(-0)/H3Y-4(-0)
Rated supply voltage
24, 100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz) (See note 1.),
12, 24, 48, 125, 100 to 110 VDC (See notes 2 and 3.)Operating voltage range
All rated voltages except 12 VDC: 85% to 110% of rated supply voltage
12 VDC: 90% to 110% of rated supply voltage (See note 4.)Reset voltage
10% min. of rated supply voltage (See note 5.)
Power consumption
100 to 120 VAC:
Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz
Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz
200 to 230 VAC:
Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz
Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz
24 VAC:
Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz
Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz
12 VDC:
Relay ON: Approx. 1.1 W at 12 VDC
Relay OFF: Approx. 0.1 W at 12 VDC
24 VDC:
Relay ON: Approx. 1.1 W at 24 VDC
Relay OFF: Approx. 0.1 W at 24 VDC
48 VDC:
Relay ON: Approx. 1.2 W at 48 VDC
Relay OFF: Approx. 0.3 W at 48 VDC
100 to 110 VDC:
Relay ON: Approx. 1.6 W at 110 VDC
Relay OFF: Approx. 0.4 W at 110 VDC
125 VDC:
Relay ON: Approx. 1.6 W at 125 VDC
Relay OFF: Approx. 0.4 W at 125 VDCControl outputs
H3Y-2(-0): 5 A at 250 VAC, resistive load (cosΦ = 1)
H3Y-4(-0): 3 A at 250 VAC, resistive load (cosΦ = 1)Note:
1.Do not use the output from an inverter as the power supply.
2.With DC ratings, single-phase full-wave rectified power sources may be used.
3.Only the H3Y-2 and H3Y-2-0 Series include 2-VDC models.
4.Use the Timer within 90% to 110% of the rated supply voltage (95% to 110% for 12 VDC) when using it continuously under an ambient operating temperature of 50°C.
5.Set the reset voltage as follows to ensure proper resetting.
100 to 120 VAC:10 VAC max.
200 to 230 VAC:20 VAC max.
100 to 110 VDC:10 VDC max.Characteristics
Accuracy of operating time
±1% FS max. (0.5 s range: ±1%±10 ms max.)
Setting error
(see note 1)±10%±50 ms FS max.
Reset time
Min. power-opening time: 0.1 s max. (including halfway reset)
Reset voltage
10% max. of rated supply voltage
Influence of voltage
(see note 1)±2% FS max.
Influence of temperature
(see note 1)±2% FS max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts)
(see note 2)
2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output)
(see note 2)
2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model)
(see note 2)
1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)Vibration resistance
Destruction: 10 to 55 Hz, 0.75-mm single amplitude
Malfunction: 10 to 55 Hz, 0.5-mm single amplitudeShock resistance
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)Ambient temperature
Operating: -10°C to 50°C (with no icing)
Storage: -25°C to 65°C (with no icing)Ambient humidity
Operating: 35% to 85%
Life expectancy
Mechanical:10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
H3Y-2: 500,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h)
H3Y-4: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h)Impulse withstand voltage
Between power terminals:
3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1 kV for 12 VDC, 24 VDC, 48 VDC
Between exposed non-current-carrying metal parts:
4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1.5 kV for 12 VDC, 24 VDC, 48 VDCNoise immunity
±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity
Destruction: 8 kV
Malfunction: 4 KvEnclosure rating
IP40
Weight
Approx. 50 g
EMC
(EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5: 2 kV line to ground (level 3)
1 kV line to line (level 3)Approved standards
UL508, CSA C22.2 No. 14, Lloyds
Conforms to EN61812-1 and IEC60664-1.
(2.5 kV/2 for H3Y-2/-2-0, 2.5 kV/1 for H3Y-4/-4-0)
Output category according to EN60947-5-1.Note:
1.Add ±10 ms to the above value for the 0.5 s range model.
2.Terminal screw sections are excluded.
Caution: In the interest of product improvement, specifications are subject to change without notice.
No comment |