PLCAGE:Multimeter 41/2 Digital VC86E VICTOR

Measuring function

Range

Measuring range

Resolving power

Accuracy

Remark

DC Voltage

 

4V

-4.000V~4.000V

1mV

0.2%+4

imput impedance:10MΩ

40V

-40.00V~40.00V

0.01V

0.2%+4

400V

-400.0V~400.0V

0.1V

0.2%+4

1000V

-1000V~1000V

1V

0.2%+4

AC Voltage

 (40Hz~500Hz)

(5%~100%RANG)

400mV

0~400.0mV

0.1mV

1%+4

imput impedance:10MΩ

< 100pF

4V

0~4.000V

1mV

0.5%+4

40V

0~40.00V

0.01V

0.5%+4

400V

0~400.0V

0.1V

0.5%+4

750V

0~750V

1V

1%+4

DC Mv Voltage

40mV

-40.00 mV~40.00mV

0.01mV

0.2%+4

imput impedance:10MΩ

400mV

-400.0mV~400.0mV

0.1mV

0.2%+4

OHM

400Ω

0~400.0Ω

0.1Ω

0.2%+4

Plough voltage:0.4V

Not including the accuracy of down-lead resistance

4KΩ

0~4.000KΩ

0.2%+4

40KΩ

0~40.00KΩ

0.01 KΩ

0.2%+4

400KΩ

0~400.0KΩ

0.1 KΩ

0.2%+4

4MΩ

0~4.000MΩ

1 KΩ

0.2%+4

40MΩ

0~40.00MΩ

0.01 MΩ

1 %+4

DC Current

4A

-4.000A~4.000A

0.001A

1.5%+3

Input impedance:0.01Ω

10A

-10.00A~10.00A

0.01A

1.5%+3

AC Current

ACA

(40Hz~200Hz)

(5%~100%RANG)

4A

0~4.000A

0.001A

1.5%+3

Input impedance:0.01Ω

10A

0~10.00A

0. 01A

1.5%+3

DCmA

40mA

-40.00mA~40.00mA

0.01mA

0.2%+4

Input impedance:1Ω

400mA

-400.0mA~400.0mA

0.1 mA

0.2%+4

ACmA

(40Hz~500Hz)

(5%~100%RANG)

40mA

0~40.00mA

0.01 mA

0.5%+4

Input impedance:1Ω

400mA

0~400.0mA

0.1 mA

0.5%+4

DCuA

DCuA

400uA

-400.0uA~400.0uA

0.1 uA

0.2%+4

Input impedance:100Ω

4000uA

-4000uA~4000uA

1 uA

0.2%+4

ACuA

(40Hz~400Hz)

(5%~100%RANG)

400uA

0~400.0uA

0.1 uA

0.5%+4

Input impedance:100Ω

4000uA

0~4000uA

1 uA

0.5%+4

Frequency

50Hz

0~50.0Hz

0.01Hz

0.1%+3

Auto range

500Hz

0~500.0Hz

0.1Hz

0.1%+3

5KHz

0~5.000kHz

1Hz

0.1%+3

50KHz

0~50.00kHz

0.01KHz

0.1%+3

100KHz

0~100.0kHz

0.1KHz

0.1%+3

Duty cycle

0.1%

~99%

 

0.1%

1%

 

Diode test

1V

 

0.001V

10%

ploughvoltage1.1V~1.6V

Current of short circuit:0.6mA

Continuity test

≤50ΩBB

 

0.1Ω

Not Specified

 

Capacitance

50nF

0~50.00nF

0.01nF

2%+5

Auto range

About need 30s in the range of 100uF

500nF

0~500.0nF

0.1nF

2%+5

5μF

0~5.000μF

0.001uF

5%+5

50μF

0~50.00μF

0.01uF

5%+5

100μF

0~100.0μF

0.1uF

5%+5

Thermocouple

K

-200~950

1°C

0.5%+2(≤-100?)

0.5%+1(>-100?)

Adopt ITS-90 thermometric scale not including the accuracy of inner temperature compensatory transducer

Thermo resistance

PT100

-200~700

1°C

0.5%+2

Pt100-385thermometric scale not includig the accuracy of down-lead resistance

  

User Comment