Your Position: Home > Instrumentation > Digital multimeter > VC79 VICTOR 79 processmeter new in box

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

VC79 VICTOR 79 processmeter new in box

prevnext

VC79 VICTOR 79 processmeter new in box
  • NO.: VC79
  • Weight: 500gram
  • Market price: $ 990.0
  • Shop price: $ 300.0
  • Goods click count: 307
  • Total:
  • Quantity:
Add to cart collect
  

Description

PLCAGE:Multimeter digital VC79 VICTOR

Meansuring function

Range

Measuring range

Resolving power

Accuracy

Remark

DC Voltage

4V

-4.000V~4.000V

1mV

0.2%+4

Input impedance:10MΩ

40V

-40.00V~40.00V

0.01V

0.2%+4

400V

-400.0V~400.0V

0.1V

0.2%+4

AC Voltage

400mV

0~400.0mV

0.1mV

1%+4

Input impedance:10MΩ

<100pF

4V

0~4.000V

1mV

0.5%+4

40V

0~40.00V

0.011V

0.5%+4

400V

0~400.0V

0.1V

0.5%+4

DC Mv Voltage

40mV

-40.00mV~40.00mV

0.01mV

0.2%+4

Input impedance:10MΩ

400mV

-400.0mV~400.0mV

0.1mV

0.2%+4

OHM

400Ω

0~400.0Ω

0.1Ω

0.2%+4

Plough voltage:0.4V

Not including the accuracy of down-lead resistance

4kΩ

0~4.000kΩ

0.2%+4

40kΩ

0~40.00kΩ

0.01kΩ

0.2%+4

400kΩ

0~400.0kΩ

0.1kΩ

0.2%+4

4MΩ

0~4.000MΩ

1kΩ

0.2%+4

40MΩ

0~40.00MΩ

0.01MΩ

1%+4

DC Current

40mA

-40.00mA~40.00mA

0.01mA

0.2%+4

Input impedance:1Ω

400mA

-400.00mA~400.00mA

0.1mA

0.2%+4

AC Current

40mA

0~40.00mA

0.01mA

0.5%+4

Input impedance:1Ω

400mA

0~400.00mA

0.1mA

0.5%+4

Frequency

50Hz

0~50.0 Hz

0.01Hz

0.1%+3

 

500Hz

0~500.0 Hz

0.1Hz

0.1%+3

5kHz

0~5.000 kHz

1Hz

0.1%+3

50kHz

0~50.00k Hz

0.01kHz

0.1%+3

100kHz

0~100.0k Hz

0.1kHz

0.1%+3

Duty cycle

0.1%~99%

 

0.1%

1%

 

Diode test

1V

 

0.001V

10%

Plough voltage 1.1V~1.6V

Current of short circuit:0.6mA

Continuity test

≤50ΩBB

 

0.1Ω

 

Thermocouple

R

-40?~1760?

1?

0.5%+3(≤100?) 0.5%+2( >100?)

Adopt ITS-90 thermometric scale not including the accuracy of RJC error RJC error: ±2?

S

-20?~1760?

K

-200?~950?

0.2%+2(≤100?)

0.5%+1( >100?)

E

-200?~500?

J

-200?~700?

T

-200?~400?

N

-200?~1000?

0.5%+3(400~600?)

0.5%+2( >600?)

B

400?~1800?

Thermo resistance

Pt100

-200?~700?

1?

0.5%+2

Pt100-385 thermometric scale. Not including the accuracy of down-lead resistance

Cu50

-50?~150?

0.5%+4

Output function: 

Function

Range

Setting range

Resolving power

Accuracy

Remark

OHM

400Ω

0~400.0Ω

0.1Ω

0.2%+4

±1mAcurrent not includingthe accuracy of down-lead resistance

DCmV

100mV

-10.00mV~110.00mV

0.01mV

0.2%+4

Max output current:5mA

DCV

5V

-0.5000V~5.5000V

1mV

0.2%+4

Max output current5mA

FREQ

100Hz

1.0Hz~110.0Hz

0.1Hz

0.2%+2

50% Duty cycle 5V p-p

1kHz

0.100Hz~1.100Hz

0.001kHz

0.2%+2

10kHz

1.0kHz~11.0kHz

0.1kHz

0.2%+2

Analog transducer XMT

-20mA

0~-22.000mA

0.01mA

0.2%+4

Outside power supply 28V when 20mA 1kΩ resistance

DC Mv

20mA

0~22.000mA

0.01mA

0.2%+4

Outside power supply 15V when 20mA

400Ω resistance

Thermocouple

R

-40?~1760?

1?

0.2%+3

(≤100?)

0.2%+2

( >100?)

Adopt ITS-90 thermometric scale not including the accuracy of RJC error RJC error: ±2?

S

-20?~1760?

0.1?

K

-200?~1370?

0.2%+20

(≤-100?)

0.2%+10

( >-100?)

E

-200?~1000?

J

-200?~1200?

T

-200?~400?

N

-200?~1300?

B

400?~1800?

1?

0.2%+3

(400~600?)

0.2%+2

( >600?)

Thermo resistance

Pt100

-200?~850?

0.1?

0.2%+6

Pt100-385 thermometric scale±1mA not including the accuracy of down-lead resistance

Cu50

-50?~150?

 

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: