PLCAGE:Multimeter digital VC79 VICTOR
Meansuring function | Range | Measuring range | Resolving power | Accuracy | Remark |
DC Voltage | 4V | -4.000V~4.000V | 1mV | 0.2%+4 | Input impedance:10MΩ |
40V | -40.00V~40.00V | 0.01V | 0.2%+4 | ||
400V | -400.0V~400.0V | 0.1V | 0.2%+4 | ||
AC Voltage | 400mV | 0~400.0mV | 0.1mV | 1%+4 | Input impedance:10MΩ <100pF |
4V | 0~4.000V | 1mV | 0.5%+4 | ||
40V | 0~40.00V | 0.011V | 0.5%+4 | ||
400V | 0~400.0V | 0.1V | 0.5%+4 | ||
DC Mv Voltage | 40mV | -40.00mV~40.00mV | 0.01mV | 0.2%+4 | Input impedance:10MΩ |
400mV | -400.0mV~400.0mV | 0.1mV | 0.2%+4 | ||
OHM | 400Ω | 0~400.0Ω | 0.1Ω | 0.2%+4 | Plough voltage:0.4V Not including the accuracy of down-lead resistance |
4kΩ | 0~4.000kΩ | 1Ω | 0.2%+4 | ||
40kΩ | 0~40.00kΩ | 0.01kΩ | 0.2%+4 | ||
400kΩ | 0~400.0kΩ | 0.1kΩ | 0.2%+4 | ||
4MΩ | 0~4.000MΩ | 1kΩ | 0.2%+4 | ||
40MΩ | 0~40.00MΩ | 0.01MΩ | 1%+4 | ||
DC Current | 40mA | -40.00mA~40.00mA | 0.01mA | 0.2%+4 | Input impedance:1Ω |
400mA | -400.00mA~400.00mA | 0.1mA | 0.2%+4 | ||
AC Current | 40mA | 0~40.00mA | 0.01mA | 0.5%+4 | Input impedance:1Ω |
400mA | 0~400.00mA | 0.1mA | 0.5%+4 | ||
Frequency | 50Hz | 0~50.0 Hz | 0.01Hz | 0.1%+3 | |
500Hz | 0~500.0 Hz | 0.1Hz | 0.1%+3 | ||
5kHz | 0~5.000 kHz | 1Hz | 0.1%+3 | ||
50kHz | 0~50.00k Hz | 0.01kHz | 0.1%+3 | ||
100kHz | 0~100.0k Hz | 0.1kHz | 0.1%+3 | ||
Duty cycle | 0.1%~99% | 0.1% | 1% | ||
Diode test | 1V | 0.001V | 10% | Plough voltage 1.1V~1.6V Current of short circuit:0.6mA | |
Continuity test | ≤50ΩBB | 0.1Ω | |||
Thermocouple | R | -40?~1760? | 1? | 0.5%+3(≤100?) 0.5%+2( >100?) | Adopt ITS-90 thermometric scale not including the accuracy of RJC error RJC error: ±2? |
S | -20?~1760? | ||||
K | -200?~950? | 0.2%+2(≤100?) 0.5%+1( >100?) | |||
E | -200?~500? | ||||
J | -200?~700? | ||||
T | -200?~400? | ||||
N | -200?~1000? | 0.5%+3(400~600?) 0.5%+2( >600?) | |||
B | 400?~1800? | ||||
Thermo resistance | Pt100 | -200?~700? | 1? | 0.5%+2 | Pt100-385 thermometric scale. Not including the accuracy of down-lead resistance |
Cu50 | -50?~150? | 0.5%+4 |
Output function:
Function | Range | Setting range | Resolving power | Accuracy | Remark |
OHM | 400Ω | 0~400.0Ω | 0.1Ω | 0.2%+4 | ±1mAcurrent not includingthe accuracy of down-lead resistance |
DCmV | 100mV | -10.00mV~110.00mV | 0.01mV | 0.2%+4 | Max output current:5mA |
DCV | 5V | -0.5000V~5.5000V | 1mV | 0.2%+4 | Max output current5mA |
FREQ | 100Hz | 1.0Hz~110.0Hz | 0.1Hz | 0.2%+2 | 50% Duty cycle 5V p-p |
1kHz | 0.100Hz~1.100Hz | 0.001kHz | 0.2%+2 | ||
10kHz | 1.0kHz~11.0kHz | 0.1kHz | 0.2%+2 | ||
Analog transducer XMT | -20mA | 0~-22.000mA | 0.01mA | 0.2%+4 | Outside power supply 28V when 20mA 1kΩ resistance |
DC Mv | 20mA | 0~22.000mA | 0.01mA | 0.2%+4 | Outside power supply 15V when 20mA 400Ω resistance |
Thermocouple | R | -40?~1760? | 1? | 0.2%+3 (≤100?) 0.2%+2 ( >100?) | Adopt ITS-90 thermometric scale not including the accuracy of RJC error RJC error: ±2? |
S | -20?~1760? | 0.1? | |||
K | -200?~1370? | 0.2%+20 (≤-100?) 0.2%+10 ( >-100?) | |||
E | -200?~1000? | ||||
J | -200?~1200? | ||||
T | -200?~400? | ||||
N | -200?~1300? | ||||
B | 400?~1800? | 1? | 0.2%+3 (400~600?) 0.2%+2 ( >600?) | ||
Thermo resistance | Pt100 | -200?~850? | 0.1? | 0.2%+6 | Pt100-385 thermometric scale±1mA not including the accuracy of down-lead resistance |
Cu50 | -50?~150? |
PLCAGE:Multimeter digital VC79 VICTOR
Meansuring function
Range
Measuring range
Resolving power
Accuracy
Remark
DC Voltage
4V
-4.000V~4.000V
1mV
0.2%+4
Input impedance:10MΩ
40V
-40.00V~40.00V
0.01V
0.2%+4
400V
-400.0V~400.0V
0.1V
0.2%+4
AC Voltage
400mV
0~400.0mV
0.1mV
1%+4
Input impedance:10MΩ
<100pF
4V
0~4.000V
1mV
0.5%+4
40V
0~40.00V
0.011V
0.5%+4
400V
0~400.0V
0.1V
0.5%+4
DC Mv Voltage
40mV
-40.00mV~40.00mV
0.01mV
0.2%+4
Input impedance:10MΩ
400mV
-400.0mV~400.0mV
0.1mV
0.2%+4
OHM
400Ω
0~400.0Ω
0.1Ω
0.2%+4
Plough voltage:0.4V
Not including the accuracy of down-lead resistance
4kΩ
0~4.000kΩ
1Ω
0.2%+4
40kΩ
0~40.00kΩ
0.01kΩ
0.2%+4
400kΩ
0~400.0kΩ
0.1kΩ
0.2%+4
4MΩ
0~4.000MΩ
1kΩ
0.2%+4
40MΩ
0~40.00MΩ
0.01MΩ
1%+4
DC Current
40mA
-40.00mA~40.00mA
0.01mA
0.2%+4
Input impedance:1Ω
400mA
-400.00mA~400.00mA
0.1mA
0.2%+4
AC Current
40mA
0~40.00mA
0.01mA
0.5%+4
Input impedance:1Ω
400mA
0~400.00mA
0.1mA
0.5%+4
Frequency
50Hz
0~50.0 Hz
0.01Hz
0.1%+3
500Hz
0~500.0 Hz
0.1Hz
0.1%+3
5kHz
0~5.000 kHz
1Hz
0.1%+3
50kHz
0~50.00k Hz
0.01kHz
0.1%+3
100kHz
0~100.0k Hz
0.1kHz
0.1%+3
Duty cycle
0.1%~99%
0.1%
1%
Diode test
1V
0.001V
10%
Plough voltage 1.1V~1.6V
Current of short circuit:0.6mA
Continuity test
≤50ΩBB
0.1Ω
Thermocouple
R
-40?~1760?
1?
0.5%+3(≤100?) 0.5%+2( >100?)
Adopt ITS-90 thermometric scale not including the accuracy of RJC error RJC error: ±2?
S
-20?~1760?
K
-200?~950?
0.2%+2(≤100?)
0.5%+1( >100?)
E
-200?~500?
J
-200?~700?
T
-200?~400?
N
-200?~1000?
0.5%+3(400~600?)
0.5%+2( >600?)
B
400?~1800?
Thermo resistance
Pt100
-200?~700?
1?
0.5%+2
Pt100-385 thermometric scale. Not including the accuracy of down-lead resistance
Cu50
-50?~150?
0.5%+4
Output function:
Function
Range
Setting range
Resolving power
Accuracy
Remark
OHM
400Ω
0~400.0Ω
0.1Ω
0.2%+4
±1mAcurrent not includingthe accuracy of down-lead resistance
DCmV
100mV
-10.00mV~110.00mV
0.01mV
0.2%+4
Max output current:5mA
DCV
5V
-0.5000V~5.5000V
1mV
0.2%+4
Max output current5mA
FREQ
100Hz
1.0Hz~110.0Hz
0.1Hz
0.2%+2
50% Duty cycle 5V p-p
1kHz
0.100Hz~1.100Hz
0.001kHz
0.2%+2
10kHz
1.0kHz~11.0kHz
0.1kHz
0.2%+2
Analog transducer XMT
-20mA
0~-22.000mA
0.01mA
0.2%+4
Outside power supply 28V when 20mA 1kΩ resistance
DC Mv
20mA
0~22.000mA
0.01mA
0.2%+4
Outside power supply 15V when 20mA
400Ω resistance
Thermocouple
R
-40?~1760?
1?
0.2%+3
(≤100?)
0.2%+2
( >100?)
Adopt ITS-90 thermometric scale not including the accuracy of RJC error RJC error: ±2?
S
-20?~1760?
0.1?
K
-200?~1370?
0.2%+20
(≤-100?)
0.2%+10
( >-100?)
E
-200?~1000?
J
-200?~1200?
T
-200?~400?
N
-200?~1300?
B
400?~1800?
1?
0.2%+3
(400~600?)
0.2%+2
( >600?)
Thermo resistance
Pt100
-200?~850?
0.1?
0.2%+6
Pt100-385 thermometric scale±1mA not including the accuracy of down-lead resistance
Cu50
-50?~150?