Specification
3123 | √ | √ | √ | √ |
|
3125 |
| √ | √ | √ | √ |
Rated voltage | 250V | 500V | 1000V | 2500V | 5000V |
Measuring Range | 0.0~99.9MΩ 100~999MΩ 1.00~2.50GΩ | 0.0~99.9MΩ 100~999MΩ 1.00~5.00GΩ | 0.0~ 99.9MΩ 100~999MΩ 1.00~9.99GΩ | 0.0~99.9MΩ 100~999MΩ 1.00~9.99GΩ 10.0~99.9GΩ | 0.0~99.9MΩ 100~999MΩ 1.00~9.99GΩ 10.0~99.9GΩ 100~1000GΩ 1.00~1.20TΩ |
Open circuit Voltage | DC 250V + 20% ,-0% | DC 500V + 20% ,-0% | DC 1000V + 20%,-0% | DC 2500V + 20%,-0% | DC 5000V +20%,-0% |
Rated Current | 1mA--1.2mA (at 0.21MΩ load) | 1mA--1.2mA (at 0.5MΩ load) | 1mA--1.2mA (at 1MΩ load) | 1mA--1.2mA (at 2.5MΩ load) | 1mA—1.2mA (at 5MΩ load) |
Short-circuit Current | Approx. 1.3mA | ||||
Accuracy | ±5%rdg ± 3dgt / ±20%(100GΩ or more) |
Voltage monitor display for insulation resistance range
0~5000V(resolution 1V):±2%rdg±3dgt
Leakage current measurement
Current Range | Measuring Range | Accuracy |
5uA | 0.000~5.250uA | ±10%rdg±5dgt |
50uA | 5.00~52.50uA | ±2.5%rdg±5dgt |
250uA | 50.0~262.5uA | ±2.5%rdg±5dgt |
1500uA | 250~1500uA | ±2.5%rdg±5dgt |
Voltage measurement
| DC voltage | AC voltage |
Measuring range | 0~±1000V | 30 ~600V(50/60Hz) |
Resolution | 1V | |
Accuracy | ±2%rdg±3dgt |
Temperature measurement
Measuring range | Accuracy |
0.0~25.0oC | ±1oC |
25.0~70.0oC | ±2.oC |
PLCAGE: Insulation tester VICTOR 3125 VICTOR
Specification
3123
√
√
√
√
3125
√
√
√
√
Rated
voltage
250V
500V
1000V
2500V
5000V
Measuring
Range
0.0~99.9MΩ
100~999MΩ
1.00~2.50GΩ
0.0~99.9MΩ
100~999MΩ
1.00~5.00GΩ
0.0~ 99.9MΩ
100~999MΩ
1.00~9.99GΩ
0.0~99.9MΩ
100~999MΩ
1.00~9.99GΩ
10.0~99.9GΩ
0.0~99.9MΩ
100~999MΩ
1.00~9.99GΩ
10.0~99.9GΩ
100~1000GΩ
1.00~1.20TΩ
Open circuit
Voltage
DC 250V
+ 20% ,-0%
DC 500V
+ 20% ,-0%
DC 1000V
+ 20%,-0%
DC 2500V
+ 20%,-0%
DC 5000V
+20%,-0%
Rated
Current
1mA--1.2mA
(at 0.21MΩ load)
1mA--1.2mA
(at 0.5MΩ load)
1mA--1.2mA
(at 1MΩ load)
1mA--1.2mA
(at 2.5MΩ load)
1mA—1.2mA
(at 5MΩ load)
Short-circuit
Current
Approx. 1.3mA
Accuracy
±5%rdg ± 3dgt / ±20%(100GΩ or more)
Voltage monitor display for insulation resistance range
0~5000V(resolution 1V):±2%rdg±3dgt
Leakage current measurement
Current Range
Measuring Range
Accuracy
5uA
0.000~5.250uA
±10%rdg±5dgt
50uA
5.00~52.50uA
±2.5%rdg±5dgt
250uA
50.0~262.5uA
±2.5%rdg±5dgt
1500uA
250~1500uA
±2.5%rdg±5dgt
Voltage measurement
DC voltage
AC voltage
Measuring
range
0~±1000V
30 ~600V(50/60Hz)
Resolution
1V
Accuracy
±2%rdg±3dgt
Temperature measurement
Measuring range
Accuracy
0.0~25.0oC
±1oC
25.0~70.0oC
±2.oC
No comment |