Features; High Accuracy of 0.02% for source, 6 digits display for source.A dual,
Liquid Crystal Display; White LED for backlight
Function | Reference | Range | Resolution | Accuracy | Remark |
Thermocouple | R | 0?~1767? | 1? | 0~100?:1.5? | By using ITS-90 temperature scale;The accuracy does not include the error of internal temperature compensation caused by a sensor; |
100~1767?:1.2? | |||||
S | 0?~1767? | 1? | 0~100?:1.5? | ||
100~1767?:1.2? | |||||
B | 600?~1820? | 1? | 600~800?:1.5? | ||
800~1820?:1.1? | |||||
E | -200.0?~1000.0? | 0.1? | -200.0~-100.0?:0.6? | ||
-100.0~600.0?: 0.5? | |||||
600.0~1000.0?: 0.4? | |||||
K | -200.0?~1372.0? | 0.1? | -200.0~-100.0?: 0.6? | ||
-100.0~400.0?: 0.5? | |||||
400.0~1200.0?: 0.7? | |||||
1200.0~1372.0?: 0.9? | |||||
J | -200.0?~1200.0? | 0.1? | -200.0~-100.0?: 0.6? | ||
-100.0~800.0?: 0.5? | |||||
800.0~1200.0?: 0.7? | |||||
T | -250.0?~400.0? | 0.1? | -250.0~400.0?:0.6? | ||
N | -200.0?~1300.0? | 0.1? | -200.0~-100.0?: 1.0? | ||
-100.0~900.0?: 0.7? | |||||
900.0~1300.0?: 0.8? | |||||
L | -200.0?~900.0? | 0.1? | -200.0~0.0?:0.7? | ||
0.0~900.0?:0.5? | |||||
U | -200.0?~600.0? | 0.1? | -200.0~0.0?:0.7? | ||
0.0~600.0?: 0.5? |
Other feature:
1 Temperature Coefficient: 0.1 times the applicable accuracy,specification per degree
C for 5?to 18?and 28?to 50?.
2 The range of the internal temperature compensation sensor is
from 0?to 40?, Compensation error ≤±0.5?.
3 The accuracy of the temperature probe: ±0.2?.
The range of the measured temperature is form -20?-100?.
4 Maximum voltage between any output terminal and earth: 30Vp-p
5 Maximum output current: Approximately 25mA.
Multimeter 6 digit VICTOR 11+ VICTORFeatures; High Accuracy of 0.02% for source, 6 digits display for source.A dual,
Liquid Crystal Display; White LED for backlight
Function
Reference
Range
Resolution
Accuracy
Remark
Thermocouple
R
0?~1767?
1?
0~100?:1.5?
By using ITS-90 temperature scale;The accuracy does not include the error of internal temperature compensation caused by a sensor;
100~1767?:1.2?
S
0?~1767?
1?
0~100?:1.5?
100~1767?:1.2?
B
600?~1820?
1?
600~800?:1.5?
800~1820?:1.1?
E
-200.0?~1000.0?
0.1?
-200.0~-100.0?:0.6?
-100.0~600.0?: 0.5?
600.0~1000.0?: 0.4?
K
-200.0?~1372.0?
0.1?
-200.0~-100.0?: 0.6?
-100.0~400.0?: 0.5?
400.0~1200.0?: 0.7?
1200.0~1372.0?: 0.9?
J
-200.0?~1200.0?
0.1?
-200.0~-100.0?: 0.6?
-100.0~800.0?: 0.5?
800.0~1200.0?: 0.7?
T
-250.0?~400.0?
0.1?
-250.0~400.0?:0.6?
N
-200.0?~1300.0?
0.1?
-200.0~-100.0?: 1.0?
-100.0~900.0?: 0.7?
900.0~1300.0?: 0.8?
L
-200.0?~900.0?
0.1?
-200.0~0.0?:0.7?
0.0~900.0?:0.5?
U
-200.0?~600.0?
0.1?
-200.0~0.0?:0.7?
0.0~600.0?: 0.5?
Other feature:
1 Temperature Coefficient: 0.1 times the applicable accuracy,specification per degree
C for 5?to 18?and 28?to 50?.
2 The range of the internal temperature compensation sensor is
from 0?to 40?, Compensation error ≤±0.5?.
3 The accuracy of the temperature probe: ±0.2?.
The range of the measured temperature is form -20?-100?.
4 Maximum voltage between any output terminal and earth: 30Vp-p
5 Maximum output current: Approximately 25mA.
No comment |