PLCAGE: loop calibrator Fluke787 FLUKE NEWFeatures:
DMM and loop calibrator in one toolClear LCD with backlight; 4,000 counts (30,000 counts for dc current)Externally accessible battery for easy battery changes.1000V overload protection on V, ohms, frequency.150V overload protection on mA, backed up by 440 mA 1000V fuse.25% Manual Step plus Auto Step and Auto Ramp on mA output.
Specifications
Current Measurement
Range:
0-1 A
Resolution:
1 mA
Accuracy:
0.2% + 2 LSD
Range:
0-30 mA
Resolution:
0.001 mA
Accuracy:
0.05% + 2 LSD
Current Sourcing
Range:
0-20 mA or 4-20 mA
Resolution:
0.05% of span
Drive Capability:
500 Ω @ 24 mA
Frequency
to 19.999 kHz, 0.005% + 1 LSD
Continuity
Beeps for resistance < 100 ohms
Voltage measurement
Range:
0-1000 V AC or DC
Resolution:
0.1 mV to 1.0 V
Accuracy:
0.1% Rdg + 1 LSD (VDC)
Resistance measurement
to 40 MΩ, 0.2% + 1 LSD
Diode test
2.4 V shows diode voltage drop
Environmental Specifications
Operating Temperature
-20 ºC to 55 ºC
Storage Temperature
-40 ºC to 60 ºC
Humidity (Without Condensation)
95% up to 30 ºC
75% up to 40 ºC
45% up to 50 ºC
35% up to 55 ºC
Temperature Coefficient
0.05 x (specified accuracy) per ºC (for temperatures < 18 ºC or > 28 ºC)
Safety Specifications
Electrical Safety
Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92
Overvoltage category
IEC 1010-1 CAT III
Maximum voltage
1000 V rms
Mechanical & General Specifications
Size
32 x 87 x 187 mm
Weight
369 g
Batteries
Single 9V Alkaline battery (ANSI/NEDA 1604A or IEC 6LR61)
Warranty
3 years
Battery Life
50 hours typical (measurement), 12 hours typical (sourcing 12 mA)
Shock & Vibration
Random, 2g, 5-500 Hz
1 meter drop test
Display current and % of span
Yes
Auto step, auto ramp
Yes