No comment |
>
Control System >
VFD >
Panasonic VFD >
AVF200-0222 Panasonic VFD input 1 Ph 220V 10A 2.2KW 400Hz for Textile Machine 1 year WarrantyParameter
Part Number
Applicable motor
capacity (kW)
Rated Output Current
(a)
Rated Output Capacity
(KVA)
Power
Capacity
(KVA)
Power
Supply
Weight(kg)
Operation panel
Simple
panel
AVF200-0022
AVF200-0022P
0.2
1.5
0.6
0.9
1-Phase 200V
1.0
AVF200-0042
AVF200-0042P
0.4
2.5
1.0
1.3
1.0
AVF200-0072
AVF200-0072P
0.75
4.2
1.7
2.3
1.4
AVF200-0152
AVF200-0152P
1.5
7.0
2.8
3.6
1.6
AVF200-0222
AVF200-0222P
2.2
10.0
4.0
5.0
2.1
AVF200-0074
AVF200-0074P
0.75
2.1
1.7
2.6
3-Phase 400V
1.6
AVF200-0154
AVF200-0154P
1.5
4.0
3.2
4.8
1.7
AVF200-0224
AVF200-0224P
2.2
5.5
4.4
6.4
1.9
AVF200-0374
AVF200-0374P
3.7
8.7
6.9
10.4
2.0
AVF200-0554
AVF200-0554P
5.5
12
9.6
13.6
3.5
AVF200-0754
AVF200-0754P
7.5
17
13.5
17.6
3.6
AVF200-1104
AVF200-1104P
11
22
17.5
21.1
6.8
AVF200-1504
AVF200-1504P
15
31
24.5
27.7
7.0
Standard Specifications
1-phase 200 V Input Type
Items
Specifications
Standard output of applicable
motor (kW)
0.2 to 2.2 kW
Rated
output
Rated voltage
3-phase, 200 to 230 VAC (proportional to power supply voltage)
Overload current rating
150% of rated output current for 1 minute
Input
power
supply
Number of phases,
voltage and frequency
1-phase, 200 to 230 VAC, 50/60 Hz
Allowable voltage
fluctuation
+10% and –15% of rated input AC voltage
Allowable frequency
fluctuation
+-5% of rated input frequency
Instantaneous voltage drop ride-through capability
Operation continues when voltage is above 165 VAC.
Operation continues for 15 ms when voltage drops below
165 VAC.
3-phase 400 V Input Type
Items
Specifications
Standard output of applicable
motor (kW)
0.75 to 15 kW
Rated
output
Rated voltage
3-phase, 380 to 460 VAC (proportional to power supply voltage)
Overload current rating
150% of rated output current for 1 minute
Input
power
supply
Number of phases,
voltage and frequency
3-phase, 380 to 460 VAC, 50/60 Hz
Allowable voltage
fluctuation
+10% and –15% of rated input AC voltage
Allowable frequency
fluctuation
+-5% of rated input frequency
Instantaneous voltage drop ride-through capability
Operation continues when voltage is above 323 VAC.
Operation continues for 15 ms when voltage drops below
323 VAC
No comment |