No comment |
>
Control System >
VFD >
Panasonic VFD >
BFV00042GK Panasonic VFD input 1 Ph 220V 2.4A 0.4KW 250Hz 1 year Warrantyeatures
Ultra-compact
- Easy to operate using the integrated operating panel
- Cost effective
- Easy and accurate frequency control using PLC puls output
- Various types without and with brake included (1-phase)
- 8-speed control function
- Retry function
- Frequency increase, decrease and memory functions
using external switches
- Complete regeneration brake function
1-phase 230V AC Input types
MotorPower PN [kW]
Part No.
Brake
provided
not provided
0.2
BFV00022DK
0.4
BFV00042GK
BFV00042DK
0.75
BFV00072GK
BFV00072DK
1.5
BFV00152GK
BFV00152DK
3-phase 400V AC Input types
MotorPower PN [kW]
Part No.
0.75
BFV00074
1.5
BFV00154
2.2
BFV00224
3.7
BFV00374
Specifications
Input voltage
1-phase 230V AC
3-phase 400V AC
Applied motor output
0.2 to 1.5kW
0.75 to 3.7kW
Rated Output
Rated output voltage
3-phase 200 to 230V AC (proportional to power supply voltage)
3-phase 380 to 460V AC (proportional to power supply voltage)
Overload current rating
150% of rated output current for 1 minute
Input Power Supply
Phases, voltage, frequency
1-phase 200 to 230V AC 50/60Hz
3-phase 380 to 460V AC 50/60Hz
Tolerable voltage variations
+10%, –15% of rated AC input voltage
Tolerable frequency variations
+-5% of rated input frequency
Instantaneous voltage
drop resistance capacity
Continuous operation at 165V or more.
Continuous operation at less than 165V for 15ms
Continuous operation at 323V or more.
Continuous operation at less than 323V for 15ms
Output Frequency
Output frequency range
0.5 to 250Hz
Frequency display
Frequency display
Frequency accuracy
+-0.5% of selected maximum set frequency (25+-10°C) for analogue setting
Frequency setting resolution
Digital setting: 0.1Hz (1Hz over 100Hz), Analogue setting: 0.1Hz (50/60Hz mode)
Inverter control method
High carrier frequency sinusoidal PWM control (V/F control method)
Carrier frequency
Select from 9 types
(The output current must be reduced for 12.5 and 15.0kHz)
(0.8, 1.1, 1.6, 2.5, 5.0, 7.5, 10, 12.5, 15kHz
Select from 7 types
(0.8, 1.1, 1.6, 2.5, 5.0. 7.5, and 10kHz)
(The output current of 3.7kW must be reduced when set to 10kHz.)
Operation
Start/Stop
Operation panel buttons or input contact signal (wait time setting possible)
Forward/Reverse
Operation panel buttons or input contact signal (reverse rotation prohibit setting possible)
Jog operation
Operating frequency: Optional setting for 0.5 to 250Hz, Acceleration/deceleration time: Optional setting each for 0.04 to 999 seconds
Stop mode
Select from ramp-to-stop or coast-to-stop (selection changeover
Reset function
Stop signal reset, external reset, panel reset (setting possible) and power supply reset
Stop frequency
Optional setting from 0.5 to 60Hz
Instantaneous power failure restart
Function OFF, and 0Hz restart, operating frequency restart (selection changeover)
Retry function
Retry selection: Select function OFF and details of retry fault, No. of retries: Optional setting for 1 to 10 times
Control
Frequency setting signal
Local setting: Potentiometer, digital setting (operation panel)
External analog setting signal: Potentiometer (10kW, 1/4 or more), 0 to 5V, 0 to 10V,
4 to 20mA (Connect a 200 , 1/4W or more external resistor)
External digital setting signal: PWM signal (signal cycle: 0.9 to 1100ms), Frequency up SW, down SW, save SW signal
Voltage/frequency characteristics
Base frequency: 50, 60Hz fixed and optional setting between 45 and 250Hz
V/F curve: Constant torque, square torque pattern (selection changeover
2nd voltage/frequency characteristics
Optional base frequency setting for 45 to 250Hz
1st and 2nd torque boost level
Optional setting for 0 to 40%
1st and 2nd accel./Decel. Time
0.04 to 999sec. (individual accel. and decel. Time setting), Accel./Decel. Characteristics: Linear
Multi-speed frequency setting
Up to 8 preset frequency settings (optional setting)
Skip frequency setting
Up to 3 place settings (skip frequency band setting from 1 to 10Hz)
Upper and lower frequency setting
Optional setting from 0.5 to 250Hz
Bias/gain frequency settings
Bias frequency: set from –99 to 250Hz, Gain frequency: set from 0 to 250Hz
External stop function
Select from auxiliary stop or coast-to-stop (selection setting
No comment |