No comment |
>
Control System >
VFD >
TECO VFD >
3-Phase 440V 103A 55KW 75HP TECO Inverter F510-4075-H3 NEW
Detailed Parameter
440V Class
Voltage (Vac) &
Frequency (Hz)
F510 Model
Motor
Power
(Hp)
Applied
Motor
(kW)
Filter
Operator
Protection
Class
(IP55)
with
without
LED
LCD
3ph
380~480V
+10%/-15%
50/60Hz
F510-4005-H3
5
3.7
O
O
F510-4008-H3
7.5
5.5
O
O
F510-4010-H3
10
7.5
O
O
F510-4015-H3
15
11
O
O
F510-4020-H3
20
15
O
O
F510-4030-H3
30
20
O
O
F510-4025-H3
25
18.5
O
O
F510-4040-H3
40
30
O
O
F510-4050-H3
50
37
O
O
F510-4060-H3
60
45
O
O
F510-4075-H3
75
55
O
O
F510-4100-H3
100
75
O
O
F510-4125-H3
125
94
O
O
F510-4150-H3
150
112
O
O
F510-4175-H3
175
130
O
O
F510-4215-H3
215
160
O
O
F510-4250-H3
250
185
O
O
F510-4300-H3
300
220
O
O
F510-4375-H3
375
280
O
O
F510-4425-H3
425
317
O
O
F510-4535-H3
535
400
O
O
F510-4670-H3
670
500
O
O
F510-4800-H3
800
600
O
O
Notes:
1. Shaded Section: Models currently under Development.
2. Short Circuit Rating: 400V Class: 5KA.
Environment
The environment will directly affect the proper operation and the life span of the inverter. To ensure that the inverter will give maximum service life, please comply with the following environmental conditions:
Protection
Protection
Class
IP20/ NEMA 1, IP00
IP55/ NEMA 12
Ambient Environment
Operating
Temperature
Ambient Temperature: -10°C - +40°C (14 -104 °F)
Without Cover: -10°C - +50°C (14-122 °F)
If several inverters are placed in the same control panel, provide a heat removal means to
maintain ambient temperatures below 40°C
Storage
Temperature
-20°C - +70°C (-4 -158 °F)
Humidity
95% non-condensing
Relative humidity 5% to 95%, free of moisture.
(Follow IEC60068-2-78 standard)
Altitude
< 1000m (3,281 ft.)
Installation
Site
Avoid direct sunlight.
Avoid exposure to rain or moisture.
Avoid oil mist and salinity.
Avoid corrosive liquid and gas.
Avoid dust, lint fibers, and small metal filings.
Avoid electromagnetic interference (soldering machines, power machines).
Keep away from radioactive and flammable materials.
Avoid vibration (stamping, punching machines etc.).
Add a vibration-proof pad if the situation cannot be avoided.
Shock
Maximum acceleration: 1.2G (12m/s²), from 49.84 to 150 Hz
Displacement amplitude : 0.3mm (peak value), from 10 to 49.84 Hz
(Follow IEC60068-2-6 standard)
Dimension
No comment |