CLOSE LOOP VECTOR CONTROL FERQUENCY INVERTER/DRIVE
Technical Features
I/O features
Power range
3 AC 380-480V +-15% 0.75KW-3000KW
Input Frequency Range
47~63Hz
Output Voltage Range
0~rated input voltage
Output Frequency Range
0~1500Hz
I/O terminals
Input terminals
Programmable DI: 5(4 input can be extended by I/O extension card) High speed pulse input: 1(HDI1)
Programmable AI: AI1: 0-10V, AI2: 0-10V or 0-20mA, AI3 (-10V~+10V) and AI4 (0~10V or 0~20mA) can be extended by I/O extension card.
Output terminals
Programmable Open Collector Output: provide 1 output terminal and 1 output (open collector or high speed pulse output selectable) can be extended by I/O extension card.
Relay output: provide 2 output terminals and 1 output can be extended by I/O extension card.
Analog output: provide 1 output terminal (AO1: 0/4-20mA or 0-10V) and 1 output (Ao2: 0/4-20mA or 0/2-10V) can be extended by I/O extension card.
Communication terminals
Provide RS485 communication interface, adopt Modbus-RTU communication mode
Control Function
Control mode
V/F control; Sensorless Vector Control (SVC); Vector Control (VC)
Speed Adjusting Range
1:100 (SVC), 1:1000(VC)
Overload Capacity
60s with 150% rated current, 10s with 180% rated current
Frequency reference source
Keypad, Analog input, Serial communication, Multi-step speed, PID and soon. The combination of multi-modes and switching between different modes can be realized.
Other functions
Traverse Control Function
PID Control Function
Carrier frequency: 1.0kHz-16kHz
Starting torque: 150% of rated torque at 0.5Hz (SVC)
180% of rated torque at 0Hz(VC)
Speed accuracy: +-0.5% of maximum speed (SVC)/ +- 0.02% of maximum speed(VC)
Simple PLC and Multi-step speed control function: 16 steps speed can be set.
None-stop when instantaneous power off
Speed trace function: start the motor smoothly
Automatic voltage regulation function
Up to 29 fault protection: over current, over voltage, under voltage. Over temperature, phase failure , over load etc.
Power Ratings
Model No.
Rated Power (kW)
Rated input current(A)
Rated output current (A)
3AC 380V -15%~15%
CHV100-1R5G-4
1.5
5
3.7
CHV100-2R2G-4
2.2
5.8
5.0
CHV100-004G-4
4
10
9
CHV100-5R5G-4
5.5
15
13
CHV100-7R5G-4
7.5
20
17
CHV100-011G-4
11
26
25
CHV100-015G-4
15
35
32
CHV100-018G-4
18.5
38
37
CHV100-022G-4
22
46
45
CHV100-030G-4
30
62
60
CHV100-037G-4
37
76
75
CHV100-045G-4
45
90
90
CHV100-055G-4
55
105
110
CHV100-075G-4
75
140
150
CHV100-090G-4
90
160
176
CHV100-110G-4
110
210
210
CHV100-132G-4
132
240
250
CHV100-160G-4
160
290
300
CHV100-185G-4
185
330
340
CHV100-200G-4
200
370
380
CHV100-220G-4
220
410
415
CHV100-250G-4
250
460
470
CHV100-280G-4
280
500
520
CHV100-315G-4
315
580
600
CHV100-350G-4
350
620
640
CHV100-400G-4
400
670
690
CHV100-500G-4
500
835
860
CHV100-630G-4
630
1050
1100
Applications
Printing machine, dying machine, paper machine, wind and unwind, high accuracy machine tool, cutting machine, steel rolling, metal, wire machine, drawbench, position control, zero speed servo control.
Wiring
No comment |