Standard Specifications
Three-phase 400V Series
3.7~55KW
Item | Specifications | ||||||||||||
Type(FRNxxxF1S-4Cxxx) | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | ||
Nominal applied motor [KW] | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | ||
Output ratings | Rated capacity[KVA] | 6.8 | 9.5 | 12 | 17 | 22 | 28 | 33 | 44 | 54 | 64 | 77 | |
Rated voltage[V] | Three-phase 380 to 480V(with AVR) | ||||||||||||
Rated Current[A] | 9.0 | 12.5 | 16.5 | 23 | 30 | 37 | 44 | 59 | 72 | 85 | 105 | ||
Rated Overload capability | 120% for 1min | ||||||||||||
Rated frequency[Hz] | 50,60Hz | ||||||||||||
Input Rating | Rated current[A] | With DCR | 7.5 | 10.6 | 14.4 | 21.1 | 28.8
| 35.5 | 42.2 | 57.0 | 68.5 | 83.2 | 102
|
Without DCR | 13.0 | 17.3 | 23.2 | 33.0 | 43.8 | 52.3 | 60.6 | 77.9 | 94.3 | 114 | 140 | ||
Required power supply capacity[KVA] | With DCR | 5.3 | 7.4 | 10 | 15 | 20 | 25 | 30 | 40 | 48 | 58 | 71 | |
Braking | Torque[%] | 20 | 10 to 15 | ||||||||||
DC injection braking | Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% | ||||||||||||
DC reactor (DCR) | Optional | ||||||||||||
Applicable safety standards | UL508C, C22.2No.14, EN50178: 1997 | ||||||||||||
Enclosure (IEC60529) | IP20 (IEC60529) closed type, UL open type | IP00 open type, UL open type | |||||||||||
Cooling method | Fan cooling | ||||||||||||
Weight/Mass[kg] | 3.4 | 3.4 | 5.8 | 6.0 | 6.9 | 9.4 | 9.9 | 11.5 | 23 | 24 | 33 |
7.5~560KW
Item | Specifications | |||||||||||||||
Type(FRNxxxF1S-4Cxxx) | 75 | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | ||
Nominal applied motor [KW] | 75 | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | ||
Output ratings | Rated capacity[KVA] | 105 | 128 | 154 | 182 | 221 | 274 | 316 | 396 | 445 | 495 | 563 | 640 | 731 | 792 | |
Rated voltage[V] | Three-phase 380 to 480V(with AVR) |
|
|
| ||||||||||||
Rated Current[A] | 139 | 168 | 203 | 240 | 290 | 360 | 415 | 520 | 585 | 650 | 740 | 840 | 960 | 1040 | ||
Rated Overload capability | 120% for 1min | |||||||||||||||
Rated frequency[Hz] | 50,60Hz | |||||||||||||||
Input Rating | Rated current[A] | With DCR | 138 | 164 | 201 | 238 | 286
| 357 | 390 | 500 | 559 | 628 | 705
| 789 | 881 | 990 |
Without DCR | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | ||
Required power supply capacity[KVA] | With DCR | 96 | 114 | 140 | 165 | 199 | 248 | 271 | 347 | 388 | 435 | 489 | 547 | 611 | 686 | |
Braking | Torque[%] | 10 to 15 | ||||||||||||||
DC injection braking | Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% | |||||||||||||||
DC reactor (DCR) | Standard | |||||||||||||||
Applicable safety standards | UL508C, C22.2No.14, EN50178: 1997(applying) | |||||||||||||||
Enclosure (IEC60529) | IP00 open type, UL open type | |||||||||||||||
Cooling method | Fan cooling | |||||||||||||||
Weight/Mass[kg] | 34 | 42 | 45 | 63 | 67 | 96 | 98 | 162 | 165 | 282 | 286 | 355 | 360 | 360 |
400V Three-phase 1040A 560KW FRN560F1S-4C FUJI FRENIC-VP Inverter
Features
1. The effect of energy saving has updated again.
2. Simple structure, convenient manufacturing.
3. Durable design-10 years using life.
4. Fit with the HVAC (Hole Ventilator Air conditioner).
5. The design is fully considering the ambient and controlled board.
6. Easy operating
Standard Specifications
Three-phase 400V Series
3.7~55KW
Item
Specifications
Type(FRNxxxF1S-4Cxxx)
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
Nominal applied motor [KW]
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
Output ratings
Rated capacity[KVA]
6.8
9.5
12
17
22
28
33
44
54
64
77
Rated voltage[V]
Three-phase 380 to 480V(with AVR)
Rated Current[A]
9.0
12.5
16.5
23
30
37
44
59
72
85
105
Rated Overload capability
120% for 1min
Rated frequency[Hz]
50,60Hz
Input Rating
Rated current[A]
With DCR
7.5
10.6
14.4
21.1
28.8
35.5
42.2
57.0
68.5
83.2
102
Without DCR
13.0
17.3
23.2
33.0
43.8
52.3
60.6
77.9
94.3
114
140
Required power supply capacity[KVA]
With DCR
5.3
7.4
10
15
20
25
30
40
48
58
71
Braking
Torque[%]
20
10 to 15
DC injection braking
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%
DC reactor (DCR)
Optional
Applicable safety standards
UL508C, C22.2No.14, EN50178: 1997
Enclosure (IEC60529)
IP20 (IEC60529) closed type, UL open type
IP00 open type, UL open type
Cooling method
Fan cooling
Weight/Mass[kg]
3.4
3.4
5.8
6.0
6.9
9.4
9.9
11.5
23
24
33
7.5~560KW
Item
Specifications
Type(FRNxxxF1S-4Cxxx)
75
90
110
132
160
200
220
280
315
355
400
450
500
560
Nominal applied motor [KW]
75
90
110
132
160
200
220
280
315
355
400
450
500
560
Output ratings
Rated capacity[KVA]
105
128
154
182
221
274
316
396
445
495
563
640
731
792
Rated voltage[V]
Three-phase 380 to 480V(with AVR)
Rated Current[A]
139
168
203
240
290
360
415
520
585
650
740
840
960
1040
Rated Overload capability
120% for 1min
Rated frequency[Hz]
50,60Hz
Input Rating
Rated current[A]
With DCR
138
164
201
238
286
357
390
500
559
628
705
789
881
990
Without DCR
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Required power supply capacity[KVA]
With DCR
96
114
140
165
199
248
271
347
388
435
489
547
611
686
Braking
Torque[%]
10 to 15
DC injection braking
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%
DC reactor (DCR)
Standard
Applicable safety standards
UL508C, C22.2No.14, EN50178: 1997(applying)
Enclosure (IEC60529)
IP00 open type, UL open type
Cooling method
Fan cooling
Weight/Mass[kg]
34
42
45
63
67
96
98
162
165
282
286
355
360
360
No comment |