Your Position: Home > Control System > VFD > Delta VFD > Delta Inverter VFD drive VFD055C43A 3Phase 380V 5.5kW 7.5HP 0~600Hz water pump &Machine tool

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

Delta Inverter VFD drive VFD055C43A 3Phase 380V 5.5kW 7.5HP 0~600Hz water pump &Machine tool

prevnext

Delta Inverter VFD drive VFD055C43A 3Phase 380V 5.5kW 7.5HP 0~600Hz water pump &Machine tool
  • Market price: $ 1881.0
  • Shop price: $ 570.0
  • Goods click count: 487
  • Total:
  • Quantity:
Add to cart collect
  

Description

VFD055C43A

 


Introduction

The C2000 series AC motor drive provides the most efficient and cost-effective solution for all types of drive applications. It features precise speed, torque and position control functions that are suitable for both sensor and sensorless types of synchronous and asynchronous motors. The C2000 series is also equipped with built-in PLC functions and supports the CANopen Master/Slave extension for the ultimate in system flexibility and fast data exchange.

Features

1. Replaces traditional brake resistor to reduce heat energy.

2. Clear energy saving: more than 95% of the regenerative energy is converted into electricity and supplied back to the mains.

3. Full-load operation : input-side current THD lower than 5% and improves power factor up to 99%.

4. AC motor drives with AFE2000: supports 4-quadrant operation with variable frequencies and adjustable system.

5. Constant DC bus voltage: unaffected by mains voltage fluctuations.

Applications

1. Large-inertia load, such as centrifuge equipment, dewatering machines and roving machines.

2. 4-quadrant loads including elevators, cranes and pumpjacks (oil extraction machines)

3. Quick braking, such as machine tools, bag making machines, auto storage and retrieval systems, and lathes.

4. Long-term energy feedback, such as wind power, water power, steel printing and paper making machinery (winding equipment).

5. Improves power quality for industries such as semiconductor and panel industries.

Specifications

230V

Frame Size

A

B

C

D

E

F

Model VFD-xxxCxx

007

015

022

037

055

075

110

150

185

220

300

370

450

550

750

900

Applicable Motor Output (kW)

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

Applicable Motor Output(HP)

1

2

3

5

7.5

10

15

20

25

30

40

50

60

75

100

125

Output Rating

Normal

Duty

Rated Output Capacity(kVA)

2.0

3.2

4.4

6.8

10

13

20

26

30

36

48

58

72

86

102

138

Rated Output Current(A)

5

8

11

17

25

33

49

65

75

90

120

146

180

215

255

346

Overload Capacity

Rated Output Current: 120% for 1 minute

Max. Output Frequency(Hz)

0.00~600.00Hz

Carrier Frequency(kHz)

2~15kHz(8kHz)

2~10kHz(6kHz)

2~9kHz(4kHz)

Heavy Duty

Rated Output Capacity(kVA)

1.9

2.8

4.0

6.4

9.6

12

19

25

28

34

45

55

38

81

96

131

Rated Output Current(A)

4.8

7.1

10

16

24

31

47

32

71

86

114

139

171

204

242

329

Overload Capacity

Rated Output Current: 150% for 1 minute

Max. Output Frequency(Hz)

0.00~300.00Hz

Carrier Frequency(kHz)

2~6KHz(2kHz)

Input Rating

Input Current(A) Normal Duty

6.4

12

16

20

28

36

52

72

83

99

124

143

171

206

245

331

Input Current(A) Heavy Duty

6.1

11

15

18.5

26

34

50

68

78

95

118

136

162

196

233

315

Rated Voltage/Frequency

3-phase AC 200V~240V (-15%~+10%), 50/60Hz

Operating Voltage Range

170~265VAC

Frequency Tolerance

47~63Hz

Drive Weight

2.6+-0.3kg

5.4+-1kg

9.8+-1.5kg

38.5+-1.5kg

64.8+-1.5kg

86.5+-1.5kg

Cooling Method

Natural cooling

Fan cooling

Braking Chopper

Frame A, B, C: built in

Frame D and above: optional

DC choke

Frame A, B, C: optional

Frame D and above: built in

EMI Filter

Optional external EMI filter is available upon purchase

EMC-COP01

VFDxxxC23A: optional ; VFDxxxC23E: built in

460V Series

Frame Size

A

B

C

Model VFD-xxxCxx

007

015

022

037

040

055

075

110

150

185

200

300

Applicable Motor Output(kW)

0.75

1.5

2.2

3.7

4.0

5.5

7.5

11

15

18.5

22

30

Applicable Motor Output(HP)

1

2

3

5

5

7.5

10

15

20

25

30

40

Output Rating

Normal Duty

Rated Output Capacity (kVA)

2.4

3.2

4.8

7.2

8.4

10

14

19

25

30

36

48

Rated Output Current(A)

3.0

4.0

6.0

9.0

10.5

12

18

24

32

38

45

60

Overload Capacity

Rated output current: 120% for 1 minute

Max output Frequency(Hz)

0.00~600.00Hz

Carrier Frequency(kHz)

2~15kHz(8kHz)

2~10kHz

Heavy Duty

Rated Output Capacity (kVA)

2.3

3.0

4.5

6.5

7.6

9.6

14

18

24

29

34

45

Rated Output Current(A)

2.9

3.8

5.7

8.1

9.5

11

17

23

30

36

43

57

Overload Capacity

Rated output current: 150% for 1 minute

Max output Frequency(Hz)

0.00~300.00Hz

Carrier Frequency(kHz)

2~6kHz(2kHz)

Input Rating

Input Current (A) Normal Duty

4.3

5.9

8.7

14

15.5

17

20

26

35

40

47

63

Input Current (A) Heavy Duty

4.1

5.6

8.3

13

14.5

16

19

25

33

38

45

60

Rated Voltage/Frequency

3-phase AC 380V-480V (-15%~+10%), 50/60Hz

Operating Voltage Range

323~528Vac

Frequency Tolerance

47~63Hz

Drive Weight

2.6+-0.3Kg

5.4+-1Kg

9.8+-1.5Kg

Cooling Method

Natural Cooling

Fan Cooling

Braking Chopper

Frame A. B, C : built in; Frame D and above: optional

DC choke

Frame A. B, C : optional; Frame D and above: built in

EMI Filter

Frame A, B, C VFDxxxC43E: built-in EMI filter

Frame A, B, C VFDxxxC43A : no EMI filter(Optional external EMI filter is available upon purchase)

EMC-COP01

VFDxxxC43A: optional; VFDxxC43E: built in

Dimensions

 

Wiring

 


  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: