Your Position: Home > Control System > VFD > Delta VFD > Delta Inverter VFD drive VFD022CP43B-21 3Phase 380V 2.2kW 3HP 0~600Hz water pump &loom

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

Delta Inverter VFD drive VFD022CP43B-21 3Phase 380V 2.2kW 3HP 0~600Hz water pump &loom

prevnext

Delta Inverter VFD drive VFD022CP43B-21 3Phase 380V 2.2kW 3HP 0~600Hz water pump &loom
  • Market price: $ 1280.4
  • Shop price: $ 388.0
  • Goods click count: 233
  • Total:
  • Quantity:
Add to cart collect
  

Description

VFD022CP43B-21

Features

Delta's Sensorless Vector Control Drive CP2000 Series has extended the idea of energy saving and uses this principal as the basis of its design. The CP2000 is specifically designed for applications such as air blowers, pumps and HVAC drives with its intelligent PID control providing the greatest efficiency. The Sensorless Vector Control (SVC) offers timely response to load torque increase/decrease which satisfies customer requirements for load changes while enhancing motor performance. A 3-step V/F curve response is used in the variable torque environment to adequately adjust the input voltage and attain the greatest overall performance; this function is especially helpful in pumps and fans applications. It also includes additional functions for operation and protection in variable load environments, such as flying starts, auto-acceleration/deceleration, momentary power loss restarts, auto-tuning, and more. The CP2000 series provides you with the ultimate energy-saving solution for your applications.

Specifications

?With a built-in 10K steps Delta PLC allows user to execute distributional control and independent control when connecting to a network system. Delta CP2000 series drives provide you the intelligent control possibility beyond your imagination.

?The calendar function allows user to program the PLC procedure, the ON/OFF in chronological order, the daylight saving time and etc.

?A wide range of models (0.75~400KW) to fulfill the demands of different industries.

?The modularized design eases the maintenance and expansion.

?High speed communication interfaces with MODBUS protocol and BACnet protocol built in. Diverse communication methods to satisfy clients@@ needs on multi-controls. So the following options are available for you: the ProfiBUS-DP, the DeviceNet, the MODBUS TCP, the Ethernet-IP and the CANopen Cards.

?Long-life design and self diagnosis for key components.

?Special PCB coating design (Printed Circuit Board) for enhancing environmental tolerance.

?Complied with global safety standards: CE, UL and cUL

?Standard LCD model (IP20/NEMA1) with built-in PLC to support up to 10K steps

?Excellent heat-sink design. Able to operate at 50°C ambient temperature and to adjust automatically rated output value to make the AC drive to work continuously.

?Run fire mode while emergency to have uninterrupted smoke releasing and pressure adding

?Multi pumps control at fixed amount, fixed time circulating control. Able to control 8 pumps at the same time. (Such as Image01 and Image02, optional multi-control relay card is required.) 

Product Specifications

230V Series

Frame Size

A

B

C

D

E

Model: VFD-xxxCP23_-_

007

015

022

037

055

075

110

150

185

220

300

370

450

550

750

900

Output Rating

Light Duty

Rated Output Capacity(kVA)

2.0

3.0

4.0

6.0

8.4

12

18

24

30

36

42

58

72

86

110

128

Rated Output Current(A)

5

7.5

10

15

21

31

46

61

75

90

105

146

180

215

276

322

Applicable Motor Output(kW)

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

Applicable Motor Output(HP)

1

2

3

5

7.5

10

15

20

25

30

40

50

60

75

100

125

Overload Tolerance

120% of rated current for 1 minute

Normal Duty

Rated Output Capacity(kVA)

1.2

2.0

3.2

4.4

6.8

10

13

20

26

30

36

48

58

72

86

102

Rated Output Current(A)

3

5

8

11

17

25

33

49

65

75

90

120

146

180

215

255

Applicable Motor Output(kW)

0.4

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

Applicable Motor Output(HP)

0.5

1

2

3

5

7.5

10

15

20

25

30

40

50

60

75

100

Overload Tolerance

120% of rated current for 1 minute; 160% of rated current for 3 seconds

Max. Output Frequency(Hz)

600.00Hz

400.00Hz

Carrier Frequency(kHz)

2~15kHz(8KHz)

2~10kHz(6KHz)

2~9kHz(4KHz)

Input Rating

Input Current(A)Light Duty

6.4

9.6

15

22

25

35

50

65

83

100

116

146

180

215

276

322

Input Current(A)Normal Duty

3.9

6.4

12

16

20

28

36

52

72

83

99

124

143

171

206

245

Rated Voltage/Frequency

3-Phase AC 200V-240V(-15%~+10%), 50/60Hz

Operating Voltage Range

17~265Vac

Frequency Tolerance

47~63Hz

Cooling Method

Natural Coolong

Fan Cooling

Braking Chopper

Frame A, B, C built in

Frame D and above: optional

DC Choke

Frame A, B, C optional

Frame D and above: 3% built in

EMI Filter

Optional

                                   

460V Series

Frame

A

B

C

Models: VFD-xxxCP43_-_

VFD-xxxCP4E_-_

007

015

022

037

040

055

075

110

150

185

220

300

370

Output Rating

Light Duty

Rated Output Capacity(kVA)

2.4

3.3

4.4

6.8

8.4

10.4

14.3

19

25

30

36

48

58

Rated Output Current(A)

3

4.2

5.5

8.5

10

.5

13

18

24

32

38

45

60

73

Applicable Motor Output (kW)

0.75

1.5

2.2

3.7

4.0

5.5

7.5

11

15

18.5

22

30

37

Applicable Motor Output (HP)

1

2

3

5

5

7.5

10

15

20

25

30

40

50

Overload Tolerance

120% of rated current for 1 minute

Normal Duty

Rated Output Capacity(kVA)

2.2

2.4

3.2

4.8

7.2

8.4

10

14

19

25

30

36

48

Rated Output Current(A)

1.7

3.0

4.0

6.0

9.0

10.5

12

18

24

32

38

45

60

Applicable Motor output (kW)

0.4

0.75

1.5

2.2

3.7

4.0

5.5

7.5

11

15

18.5

22

30

Applicable Motor Output(HP)

0.5

1

2

3

5

5

7.5

10

15

20

25

30

40

Overload Tolerance

120% of rated current for 1 minute; 160% of rated current for 3 seconds

Max. output Frequency(Hz)

600.00Hz

Carrier Frequency(kHz)

2~15kHz(8kHz)

2~10kHz(6kHz)

Input Rating

Input Current(A) Light Duty

4.3

6.0

8.1

12.4

16

20

22

26

35

42

50

66

80

Input Current(A) Normal Duty

3.5

4.3

5.9

8.7

14

15.5

17

20

26

35

40

47

63

Rated Voltage/ Frequency

3-Phase AC 380V~480V(-15%~+10%), 50/60Hz

Operating Voltage Range

323~528Vac

Frequency Tolerance

47~63Hz

Cooling Method

Natural Cooling

Fan Cooling

Braking Chopper

Frame A, B, C Built-in

DC Choke

Frame A, B, C Optional

EMI Filter

Frame A, B, C of VFDxxxCP4E_-__, EMI filter Built-in

Frame A, B, C of VFDxxxCP43E_-__, EMI filter not Built-in

 

Frame

D

E

F

G

H

Models: VFD-xxxCP43_-_

450

550

750

900

1100

1320

1600

1850

2200

2800

3150

3550

4000

Output Rating

Light Duty

Rated Output Capacity(kVA)

73

88

120

143

175

207

247

295

367

422

491

544

613

Rated Output Current(A)

91

110

150

180

220

260

310

370

460

530

616

683

770

Applicable Motor Output (kW)

45

55

75

90

110

132

160

185

220

280

315

355

400

Applicable Motor Output (HP)

60

75

100

125

150

175

215

250

300

375

425

475

536

Overload Tolerance

120% of rated current for 1 minute

Normal Duty

Rated Output Capacity(kVA)

58

73

88

120

143

175

207

247

295

367

438

491

544

Rated Output Current(A)

73

91

110

150

180

220

260

310

370

460

550

616

683

Applicable Motor output (kW)

37

45

55

75

90

110

132

160

185

220

280

315

355

Applicable Motor Output(HP)

50

60

75

100

125

150

175

215

250

300

375

425

475

Overload Tolerance

120% of rated current for 1 minute; 160% of rated current for 3 seconds

Max. output Frequency(Hz)

600.00Hz

400.00Hz

Carrier Frequency(kHz)

2~10kHz(6kHz)

2~9kHz(4kHz)

Input Rating

Input Current(A) Light Duty

91

110

150

180

220

260

310

370

460

530

616

683

770

Input Current(A) Normal Duty

74

101

114

157

167

207

240

300

380

400

494

555

625

Rated Voltage/ Frequency

3-Phase AC 380V~480V(-15%~+10%), 50/60Hz

Operating Voltage Range

323~528Vac

Frequency Tolerance

47~63Hz

Cooling Method

Fan Cooling

Braking Chopper

Frame D and above: Optional

DC Choke

Frame D and above: 3% Built-in

EMI Filter

Frame D and above: Optional

                  

Applications

Fixed-displacement pumps (fix flow and fix time), building automation, factory automation, HVAC drives, cooling pumps, cooling towers and general motor applications.

Wiring Diagram

 

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: