Delta Inverter VFD drive VFD004DD21A 1Phase 220V 0.4KW 0.5HP 0.1~120Hz Food packaging1 Phase VFD 220V 0.4KW 0.5HP Delta Inverter Drive VFD004DD21A
Features
The Delta DD series elevator door control drive is an intelligent drive with outstanding features that include a modularized design for easy removal and installation of terminal blocks, a power switch designed for safety, and a built-in digital keypad that provides quick operation control. This drive offers four door control modes for door opening and closing. The distance control mode is controlled by an encoder that counts PG pulses to obtain the speed position without sensor. The speed control mode is to control the speed and it needs detection sensors to execute the door open and close action. The multi-step speed control mode generates a smooth door open-and-close curve using PLC control. The Delta DD series elevator door control drive provides a complete solution for elevator door control.
Specifications:
?Door width is determined automatically and is recorded in related elevator parameters.
?Smooth door re-open curve reduces vibration
?DEMO mode
?PM motor A, B, Z, -Z and Delta ECMD-B9160GMS series PM motor
?Supports open collector and voltage output encoder (5~12VDC) for induction motors
?Blockage detection, even if the hardware safety device has failed, VFD-DD can re-open the door according to current detection.
?Precise torque detection, keeps the door open/closed, when the door open/close time exceeds warning, it forces door open
Specifications:
230V 1-phase: 200W and 400W models
Model Name VFDXXXDD
002
004
Max. Application Motor Output(W)
200
400
Output Rating
Rated Output Capacity (KVA)
0.6
1.0
Rated Output Current for Constant Torque(A)
1.5
2.5
Maximum Output Voltage (V)
Proportional Input Voltage
Output Frequency(Hz)
0.00~120.00Hz
Carrier Frequency(kHz)
10kHz
Environment
Rated Input Current(A)
4.9A
6.5A
Voltage Tolerance
Single Phase 200-20%~240V+10%(160-264V)
Frequency Tolerance
50/60Hz+-5%(47-63Hz)
Cooling Method
200W natural cool/400W natural cool
Frame
W170 x L215 x H55mm
General Specifications
Control Characteristics
Starting Torque
At 0.5Hz,starting torque reaches above 150% at 0.5Hz; under FOC+PG mode, starting torque reaches above 150% at 0Hz.
Speed Control Range
1:100(external)PG installation can achieve 1:1000)
Speed Control Accuracy
+-0.5% (external PG installation can achieve 0.02%)
Speed Response Ability
5Hz (vector control can attain 30Hz)
Max. Output Frequency(Hz)
0.00 to 120.00 Hz
Output Frequency Accuracy
Digital command +-0.005%
Frequency Setting Resolution
Digital command +-0.01Hz
Torque Limit
200% torque current as maximum
Accel/Decel Time
0.00~600.00 sec
V/F Curve Pattern
Adjustable V/F curve of 4 independent points
Operating Characteristics
Frequency Setting Signal
Keypad
By parameter
External Signal
Multi-function input selection 1-15(15 step speeds; JOG), parameter setting on serial communication port (RS-485)
Operation Setting Signal
Keypad
Set by RUN, STOP key
External Signal
2 wires(Fwd, Rev, RUN), JOG operation, RS-485 serial interface, demo mode
Multi-Function Input Signal
Multi-step speed selection MI1~MI15, Jog , first to second accel/decal switches ,demo mode, force stop, emergency stop, operation command source, parameter lock, driver reset, open/close limit signal, door open prohibited signal ,force open signal, reposition, 2nd step open/close curve selection
Multi-Function Output Signal
(RC1, RA1, RB1), (RC2, RA2, RB2),(MO1, MO2, MO3 and MCM) Ac drive operating, frequency attained, fault indication, over torque, over voltage, operation mode, alarm indication, demo mode indication, overheat alarm, drive is ready, emergency stop, braking signal, zero speed indication. PG indication error, position detection, limit signal, re-open/close indication, position finished
Communication interface
Built-in MODBUS, customize CAN Bus
Alarm Output Contact
Contact “ON” when malfunctions occurs (relay with a “C” or “A” contact, or 2 open collector outputs)
Operation Function
AVR, 4 set fault records, reverse inhibition, DC brake, auto torque/slip compensation, auto tuning, adjustable carrier frequency, output frequency upper and lower limits, parameter reset, vector control. MODBUS communication, abnormal reset, abnormal re-start, PG feedback control, fan control, demo mode, door with auto-tuning.
Protection Function
Over voltage, over current, under current, external fault, overload, ground fault, overload, overheating, electronic thermal , PG feedback error, external limit signal error, re-open/re-close
Digital Keypad
7 function keys, 4-digit 7 segment LED, 4 status LEDs, master frequency, output frequency, output current, custom units, parameter values for setup, review and faults, RUN, STOP, RESET, FWD/REV
Built-in EMI filter
Certified to EN55011 CLASS A
Protection characteristics
Motor Protection
Electronic thermal relay protection
Over Current Protection
The current forces 180% of the over-current protection and 240% of the rated current
Overload Capacity
150% for 60 seconds; 180% for 10 seconds
Voltage Protection
Over-voltage lever: Vdc>400; low-voltage level: Vdc<200
Over-voltage Protection for Input Power
Varistor(MOV)
Overheat Protection
Built-in temperature sensor
Environment
Enclosure Rating
IP20
Operation Temperature
-100C~400C
Ambient Temperature
-200C~600C
Ambient Humidity
Below 90% RH(non-condensing)
Vibration
1.0G less than 20Hz, 0.6G at 20~60Hz
Installation Location
Altitude 1.000m or lower, keep from corrosive gasses, liquid and dust
Applications
Doors control
Dimensions
Wiring