Delta Inverter VFD drive VFD004DD21A 1Phase 220V 0.4KW 0.5HP 0.1~120Hz Food packaging

prevnext

Delta Inverter VFD drive VFD004DD21A 1Phase 220V 0.4KW 0.5HP 0.1~120Hz  Food packaging
  • Market price: $ 570.9
  • Shop price: $ 173.0
  • Goods click count: 365
  • Total:
  • Quantity:
Add to cart collect
  

Description

1 Phase VFD 220V 0.4KW 0.5HP Delta Inverter Drive VFD004DD21A

 

Features

The Delta DD series elevator door control drive is an intelligent drive with outstanding features that include a modularized design for easy removal and installation of terminal blocks, a power switch designed for safety, and a built-in digital keypad that provides quick operation control. This drive offers four door control modes for door opening and closing. The distance control mode is controlled by an encoder that counts PG pulses to obtain the speed position without sensor. The speed control mode is to control the speed and it needs detection sensors to execute the door open and close action. The multi-step speed control mode generates a smooth door open-and-close curve using PLC control. The Delta DD series elevator door control drive provides a complete solution for elevator door control. 

 

Specifications:


?Door width is determined automatically and is recorded in related elevator parameters.

?Smooth door re-open curve reduces vibration

?DEMO mode

?PM motor A, B, Z, -Z and Delta ECMD-B9160GMS series PM motor

?Supports open collector and voltage output encoder (5~12VDC) for induction motors

?Blockage detection, even if the hardware safety device has failed, VFD-DD can re-open the door according to current detection.

?Precise torque detection, keeps the door open/closed, when the door open/close time exceeds warning, it forces door open

 

 


Specifications:

230V 1-phase: 200W and 400W models

Model Name VFDXXXDD

002

004

Max. Application Motor Output(W)

200

400

Output Rating

Rated Output Capacity (KVA)

0.6

1.0

Rated Output Current for Constant Torque(A)

1.5

2.5

Maximum Output Voltage (V)

Proportional Input Voltage

Output Frequency(Hz)

0.00~120.00Hz

Carrier Frequency(kHz)

10kHz

Environment

Rated Input Current(A)

4.9A

6.5A

Voltage Tolerance

Single Phase 200-20%~240V+10%(160-264V)

Frequency Tolerance

50/60Hz+-5%(47-63Hz)

Cooling Method

200W natural cool/400W natural cool

Frame

W170 x L215 x H55mm

General Specifications

Control Characteristics

Starting Torque

At 0.5Hz,starting torque reaches above 150% at 0.5Hz; under FOC+PG mode, starting torque reaches above 150% at 0Hz.

Speed Control Range

1:100(external)PG installation can achieve 1:1000)

Speed Control Accuracy

+-0.5% (external PG installation can achieve 0.02%)

Speed Response Ability

5Hz (vector control can attain 30Hz)

Max. Output Frequency(Hz)

0.00 to 120.00 Hz

Output Frequency Accuracy

Digital command +-0.005%

Frequency Setting Resolution

Digital command +-0.01Hz

Torque Limit

200% torque current as maximum

Accel/Decel Time

0.00~600.00 sec

V/F Curve Pattern

Adjustable V/F curve of 4 independent points

Operating Characteristics

Frequency Setting Signal

Keypad

By parameter

External Signal

Multi-function input selection 1-15(15 step speeds; JOG), parameter setting on serial communication port (RS-485)

Operation Setting Signal

Keypad

Set by RUN, STOP key

External Signal

2 wires(Fwd, Rev, RUN), JOG operation, RS-485 serial interface, demo mode

Multi-Function Input Signal

Multi-step speed selection MI1~MI15, Jog , first to second accel/decal switches ,demo mode, force stop, emergency stop, operation command source, parameter lock, driver reset, open/close limit signal, door open prohibited signal ,force open signal, reposition, 2nd step open/close curve selection

Multi-Function Output Signal

(RC1, RA1, RB1), (RC2, RA2, RB2),(MO1, MO2, MO3 and MCM) Ac drive operating, frequency attained, fault indication, over torque, over voltage, operation mode, alarm indication, demo mode indication, overheat alarm, drive is ready, emergency stop, braking signal, zero speed indication. PG indication error, position detection, limit signal, re-open/close indication, position finished

Communication interface

Built-in MODBUS, customize CAN Bus

Alarm Output Contact

Contact “ON” when malfunctions occurs (relay with a “C” or “A” contact, or 2 open collector outputs)

Operation Function

AVR, 4 set fault records, reverse inhibition, DC brake, auto torque/slip compensation, auto tuning, adjustable carrier frequency, output frequency upper and lower limits, parameter reset, vector control. MODBUS communication, abnormal reset, abnormal re-start, PG feedback control, fan control, demo mode, door with auto-tuning.

Protection Function

Over voltage, over current, under current, external fault, overload, ground fault, overload, overheating, electronic thermal , PG feedback error, external limit signal error, re-open/re-close

Digital Keypad

7 function keys, 4-digit 7 segment LED, 4 status LEDs, master frequency, output frequency, output current, custom units, parameter values for setup, review and faults, RUN, STOP, RESET, FWD/REV

Built-in EMI filter

Certified to EN55011 CLASS A

Protection characteristics

Motor Protection

Electronic thermal relay protection

Over Current Protection

The current forces 180% of the over-current protection and 240% of the rated current

Overload Capacity

150% for 60 seconds; 180% for 10 seconds

Voltage Protection

Over-voltage lever: Vdc>400; low-voltage level: Vdc<200

Over-voltage Protection for Input Power

Varistor(MOV)

Overheat Protection

Built-in temperature sensor

Environment

Enclosure Rating

IP20

Operation Temperature

-100C~400C

Ambient Temperature

-200C~600C

Ambient Humidity

Below 90% RH(non-condensing)

Vibration

1.0G less than 20Hz, 0.6G at 20~60Hz

Installation Location

Altitude 1.000m or lower, keep from corrosive gasses, liquid and dust

Applications

Doors control 