DVP04PT-H2 Delta PLC 4 point 0.1 degree resolution Analog Module Original brand newDVP04PT-H2 Delta PLC 4 point 0.1 degree resolution Analog Module Original brand new
Introduction
DVP04PT-H2 is able to receive 4 points of resistance temperature detectors (PT100, PT1000, NI100, and NI1000) and convert them into 16-bit digital signals. Besides, through the user of FROM/TO instructions in DVP-EH2 MPU program, the data in DVP04PT-H2 can be read or written. There are 49 16-bit control registers (CR) in it. DVP04PT-H2 displays temperatures in Celsius (resolution: 0.1°C) and Fahrenheit (resolution: 0.1°F).
Electrical Specifications
Power supply voltage
24 VDC (20.4 to 28.8 VDC) (-15 to +20%)
Analog output channel
4 channels/module
Applicable sensors
3-WIRE PT100 / NI100 / PT1000 / NI1000 3850 PPM/°C (DIN 43760 JIS C1604-1989)
Current excitation
1.53 mA/200 uA
Range of input temp
See the table in “Temperature/Digital Value Curve” section.
Range of digital
conversion
See the table in “Temperature/Digital Value Curve” section
Resolution
16-bit (0.1°C/0.1°F)
Output impedance
0.5? or less
Overall accuracy
+-0.6% when in full scale within the range of 0 to 55°C, 32 to 131°F
Response time
400 ms × number of channels
Isolation
Isolation between digital circuits and analog circuits.
500 VDC between digital circuits and ground
500 VDC between analog circuits and ground
500 VDC between analog circuits and digital circuits
500 VDC between 24 VDC and ground
Format of digital data
15 significant bits out of 16 bits are available; in 2’s complement
Average function
Provided; available for setup in CR#2 to CR#5; Range: K1 to K100
Self-diagnosis
Upper and lower bound detection/channel
Communication mode
(RS-485)
ASCII/RTU mode. Communication speed: 4,800 / 9,600 / 19,200 / 38,400 / 57,600 / 115,200 bps. ASCII data format: 7-bit, even bit, 1 stop bit (7, E, 1). RTU data format: 8-bit, even bit, 1 stop bit (8, E, 1). RS-485 cannot be used when connected to PLC MPU.
Serial connection with
DVP-PLC MPU
The modules are numbered from “0 to 7” automatically by their distance from MPU. 0 is the closest to MPU and 7 is the furthest.
Maximum 8 modules are allowed to connect to the PLC and will not occupy any digital I/O points.
Max. rated power
consumption
24 VDC (20.4 to 28.8 VDC) (-15 to +20%), 2.5 W supplied by external power.
Operation/storage
1. Operation: 0 to 55°C (temperature), 50 to 95% (humidity), pollution degree 2
2. Storage: -25 to 70°C (temperature), 5 to 95% (humidity)
Vibration/shock
immunity
Standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)