XBC-DR60SU LS PLC XGB Series Standard Type 36-point DC Input 24-point Relay Output AC100~240V New

prevnext

XBC-DR60SU LS PLC XGB Series Standard Type 36-point DC Input 24-point Relay Output AC100~240V New
  • Market price: $ 900.9
  • Shop price: $ 273.0
  • Goods click count: 254
  • Total:
  • Quantity:
Add to cart collect
  

Description

XBC-DR60SU LS PLC XGB Series Standard Type 36-point DC Input 24-point Relay Output AC100~240V New

PLCAGE: XBC-DR60SU LS(LG) PLC XGB Series Standard Type 36-point DC Input 24-point Relay Output AC100~240V New

Features:

XBC/XEC: Terminal block type

*Supporting floating-point arithmetic

*Built-in Cnet, HSC, PID, Positioning, Pulse catch, Input filter, External Interrupt

*Expansion Cnet, Ethernet

*Download port: Serial, USB

XBC/XEC

*Economic type

- CPU processing speed: 240ns/step

- Max 38 I/O points

- Program capacity: 4Ksteps

*Standard type

- CPU processing speed: 94ns/step

- Max. 284 I/O points

- Program capacity: 15Ksteps/200KB(XBC/XEC)

*High performance type

- CPU processing speed: 83ns/step

- Max. 384 I/O points

- Program capacity: 15Ksteps/200KB(XBC/XEC)

Specifications:

Items

Specifications (“S” type)

XBC-DN40SU

XBC-DR40SU

XBC-DN60SU

XBC-DR60SU

Control method

Repetitive, cyclic, interrupt, constant scan

I/O control method

Refresh mode (Batch processing by scan synchronization), Direct mode by instruction

Programming language

Ladder diagram, Instruction List

Processing speed

94 ns/Step

Program capacity

15Kstep

Main Unit I/O points

40

(Input:24, Output:16)

40

(Input:24, Output:16)

60

(Input:36, Output:24)

60

(Input:36, Output:24)

Max. I/O points

(Main + Expansion 7 stages)

264 points

264 points

284 points

284 points

Total program

128

Operation mode

RUN, STOP, DEBUG

Self diagnosis

Detects errors of scan time, memory error, I/O error, battery error, power error, etc.

Program port

RS-232C 1 channel (Loader), USB 1 channel (U-type model)

Retain data at power failure

Latch area setting at Basic parameter

Built-in functions

RS-232C / RS-485(2CH), Pulse catch, Input filter, External interrupt,

PID control, High-speed counter, Positioning

Internal current consumption

288mA

684mA

340mA

942mA

Weight(g)

578g

594g

636g

804g

Rated voltage

AC 100 ~ 240V

Data area

P

P0000 ~ P1023F (16,384 points)

M

M0000 ~ M1023F (16,384 points)

K

K0000 ~ K4095F (65,536 points)

L

L0000 ~ L2047F (32,768 points)

F

F0000 ~ F1023F (16,384 points)

T

100ms, 10ms, 1ms: T0000 ~ T1023 (1,024) (Adjustable by parameter setting)

C

C0000 ~ C1023 (1,024)

S

S00.00 ~ S127.99

D

D0000 ~ D10239 (10,240 word)

U

U00.00 ~ U0A.31 (Analog data refresh area: 352 word)

Z

Z000 ~ Z127 (128 word)

N

N0000 ~ N10236 (10.240 word)

  

User Comment

No comment