GE Analog Current Input 4-Channel IC693ALG221
Product Description:
The 4-Channel Analog Current Input module for the Series 90-30 Programmable Logic Controller provides four input channels, each capable of converting an analog input signal to a digital signal for use as required by your application. This module provides two input ranges.
The default range is 4 to 20 mA with user data scaled so that 4 mA corresponds to a count of 0 and 20 mA corresponds to a count of 32000 with each 1000 counts representing 0.5 mA. When a jumper is added to the I/O terminal board, the input range is changed to 0 to 20 mA with user data scaled so that 0 mA corresponds to a count of 0 and 20 mA corresponds to a count of 32000 with each 800 counts representing 0.5 mA. Two range jumpers are provided with the module; one for channels one and two, and the other for channels three and four.
Features:
Specifications | |
Input Current Ranges | 4 to 20 mA and 0 to 20 mA |
Calibration | Factory calibrated to 4 "A per count |
Update Rate | 2 msec (all four channels) |
Resolution at 4-20 mA | 4μA (1 LSB = 4 μA) |
Resolution at 0-20 mA | 5μA (1 LSB = 5 μA) |
Absolute Accuracy | 0.1% full scale + 0.1% reading |
Common Mode Voltage | 200 volts |
Linearity | < 1 Least Significant Bit |
Isolation | 1500 volts between field side and logic side |
Common Mode Rejection | > 70 db at DC; >70 db at 60 Hz |
Cross-Channel Rejection | > 80 db from DC to 1 kHz |
Input Impedance | 250 ohms |
Input Filter Response | 325 Hz |
Internal Power Consumption | 100 mA from the isolated +24 volt supply |
25 mA from+5 volt bus on the backplane |
IC693ALG221 GE PLCGE Analog Current Input 4-Channel IC693ALG221
Product Description:
The 4-Channel Analog Current Input module for the Series 90-30 Programmable Logic Controller provides four input channels, each capable of converting an analog input signal to a digital signal for use as required by your application. This module provides two input ranges.
The default range is 4 to 20 mA with user data scaled so that 4 mA corresponds to a count of 0 and 20 mA corresponds to a count of 32000 with each 1000 counts representing 0.5 mA. When a jumper is added to the I/O terminal board, the input range is changed to 0 to 20 mA with user data scaled so that 0 mA corresponds to a count of 0 and 20 mA corresponds to a count of 32000 with each 800 counts representing 0.5 mA. Two range jumpers are provided with the module; one for channels one and two, and the other for channels three and four.
Features:
Specifications
Input Current Ranges
4 to 20 mA and 0 to 20 mA
Calibration
Factory calibrated to 4 "A per count
Update Rate
2 msec (all four channels)
Resolution at 4-20 mA
4μA (1 LSB = 4 μA)
Resolution at 0-20 mA
5μA (1 LSB = 5 μA)
Absolute Accuracy
0.1% full scale + 0.1% reading
Common Mode Voltage
200 volts
Linearity
< 1 Least Significant Bit
Isolation
1500 volts between field side and logic side
Common Mode Rejection
> 70 db at DC; >70 db at 60 Hz
Cross-Channel Rejection
> 80 db from DC to 1 kHz
Input Impedance
250 ohms
Input Filter Response
325 Hz
Internal Power Consumption
100 mA from the isolated +24 volt supply
25 mA from+5 volt bus on the backplane