No comment |
>
Control System >
PLC >
Panasonic PLC >
FP-X C60P AFPX-C60P Panasonic PLC AC100-240V 32 DC input points 28 PNP output points FP-X Control Unit Original NewFP-X C60P AFPX-C60P Panasonic PLC AC100-240V 32 DC input points 28 PNP output points FP-X Control Unit Original New
Features
• High-speed Operation
The 32-bit RISC processor provides the top-level processing speed in compact PLCs. The scan time is 2 ms or less for 5,000 steps. A high-speed PLC is indispensable for enhancing the functionality of equipment.
• Large Capacity Program Memory
FP-X, which is equipped with 32k steps*2 program memory, is ideal for fully covering the increasing functions, such as communications, positioning, and analog control. The sufficient program capacity can also support future equipment modifications.
• Independent Comment Memory
There are difficulties with program management on a PC, such as identifying the latest program. The use of the program in the PLC of equipment in operation is often regarded as the best option. Since FP-X has an independent comment memory, all comments can be stored in the PLC together with programs, facilitating program management and maintenance.
• Maximum Number of I/O Points
Since up to eight expansion units can be connected to one control unit, the maximum number of I/O points is 300. Furthermore, with the add-on cassette and expansion FP0 adapter connected, the number of I/O points can be increased to 382.
• Built-in 4-axis Pulse Output (Transistor Output Type)
The transistor output type C14 comes with 3-axis while C30/60 comes with 4-axis pulse output built-in the control unit. The multi-axis control, which previously required a higher-level PLC or additional positioning unit, or two or more PLC units, can now be achieved with only one FP-X transistor output type unit in a small space at a low cost. In addition, as this type does not require a pulse I/O cassette needed for a relay output type, other function expansion cassettes such as communication or analog input can be attached for more diversified applications.
• Modbus-RTU
Communicates with equipment compatible with Modbus-RTU
• Expansion Cassettes
Expansion cassettes are available for Extra digital I/O, analog, motion, Ethernet, Serial communication, etc.
General Specifications
Item
Description
Relay output type
Transistor output type
Power supply and I/O Specifications
Power supply
100 to 240 V AC (AC power), 24 V DC (DC power)
Input
24V DC °C common
Output
2 A
0.5 A
Service power supply
(AC power type only)0.15 A (C14)/ 0.4 A (C30/ C60)
Performance Specifications
Number of I/O points
C14
Input: 8 points, Output: 6 points
C30
Input: 16 points, Output: 14 points
C60
Input: 32 points, Output: 28 points
I/O points when expanded
C14
Max. 328 points (When using FP0 expansion units and add-on cassette)
C30
Max. 352 points (When using FP0 expansion units and add-on cassette)
C60
Max. 382 points (When using FP0 expansion units and add-on cassette)
Operation speed
0.32μs/step
Program memory
Flash ROM built-in (no battery backup required)
Program capcity
16 ksteps (C14), 32 ksteps (C30, C60)
Basic instructions
111
Applied instructions
216
Operation memory
Internal relay ®
4096 points
Timer/counter (T/C)
1024 points
Data register (DT)
12285 words (C14), 32765 (C30, C60)
Special functions
Pulse catch input
14 points
14 points
Interrupt input
14 points
14 points
Analog I/O
Input: Max. 24 ch, Output: Max. 12 ch (When using FP0 analog unit)
Input: Max. 4 ch (When using add-on cassette)Volume input
2 points (C14/C30), 4 points (C60)
High-speed counter
Input of main unit
Single-phase: 8 ch x Max. 10 kHz
2-phase: 4 ch Max. 5 kHzSingle-phase: 8 ch (High-speed: 4 ch, midium-speed: 4 ch)
2-phase: 4 ch (High-speed: 2 ch, midium-speed: 2ch)
With high-speed single-phase:
1 ch x Max. 100 kHz
2 ch x Max. 80 kHz
3 ch x Max. 60 kHz
4 ch x Max. 50 kHz
With high-speed 2-phase:
1 ch x Max. 35 kHz
2 ch x Max. 25 kHz
With medium-speed single-phase:
4 ch x Max. 10 kHz each
With Medium-speed 2-phase:
2 ch x Max. 5 kHz eachwhen pulse I/Ocassette installed
Single-phase: 2 ch x Max. 80 kHz, 4 ch x Max. 50 kHz
2-phase: 1 ch x Max. 30 kHz, 2 ch x Max. 25 kHzPulse I/O cassette cannot be installed.
Pulse output
Input of main unit
-
With high-speed 2 ch x Max. 100 kHz
For linear interpolation, compositespeed: 100 kHz
With medium-speed 2 ch x Max. 20 kHz
For linear interpolation, compositespeed: 20 kHzwhen pulse I/Ocassette installed
1 ch x Max. 100 kHz, 2ch x Max. 80 kHz
Pulse I/O cassette cannot be installed.
Serial interface
RS232C.RS485, USB, Ethernet
Network function
PLC Link, Computer link, Modem, Modbus-RTU
Other functions
Program editing during RUN, Constant scan, 8-digit password, Program
Control Units
Model Name
Power
Pulse Outputs
Modbus Rtu
Dc Inputs
Npn Outputs
Pnp Outputs
Relay Outputs
Program Size (K)
AFPX-C14P
AC100-240V
3 Axis
Yes
8
6
12
AFPX-C14PD
24VDC
3 Axis
Yes
8
6
12
AFPX-C14R
AC100-240V
No
Yes
8
6
12
AFPX-C14T
AC100-240V
3 Axis
Yes
8
6
12
AFPX-C14TD
24VDC
3 Axis
Yes
8
6
12
AFPX-C30P
AC100-240V
4 Axis
Yes
16
14
32
AFPX-C30PD
24VDC
4 Axis
Yes
16
14
32
AFPX-C30R
AC100-240V
No
Yes
16
14
32
AFPX-C30T
AC100-240V
4 Axis
Yes
16
16
32
AFPX-C30TD
24VDC
4 Axis
Yes
16
16
32
AFPX-C60P
AC100-240V
4 Axis
Yes
32
28
32
AFPX-C60PD
24VDC
4 Axis
Yes
32
28
32
AFPX-C60R
AC100-240V
No
Yes
32
28
32
AFPX-C60T
AC100-240V
4 Axis
Yes
32
28
32
AFPX-C60TD
24VDC
4 Axis
Yes
32
28
32
No comment |