No comment |
CJ1W-PA205R Omron PLC New in boxOmron PLC CJ1W-PA205R
Product Description and Features:?
Item Power Supply Unit
Specifications
CJ1W-PA205R
CJ1W-PA205C
CJ1W-PA202
CJ1W-PD025
CJ1W-PD022
Supply voltage
100 to 240 V AC (wide-range), 50/60 Hz
24 VDC
Operating voltage and frequency ranges
85 to 264 V AC, 47 to 63 Hz
19.2 to 28.8 V DC
21.6 to 26.4 V DC
Power consumption
100 VA max.
50 VA max.
50 W max.
35 W max.
Inrush current *1
At 100 to 120 V AC: 15 A/8 ms max. for cold start at room temperature At 200 to 240 V AC: 30 A/8 ms max. for cold start at room temperature
At 100 to 120 V AC: 20 A/8 ms max. for cold start at room temperature At 200 to 240 V AC: 40 A/8 ms max. for cold start at room temperature
At 24 V DC: 30 A/20 ms max. for cold start at room temperature
Output capacity *7
5.0 A, 5 V DC (including supply to CPU Unit)
2.8 A, 5 V DC (including supply to CPU Unit)
5.0 A, 5 V DC (including supply to CPU Unit)
2.0 A, 5 V DC (including supply to CPU Unit)
0.8 A, 24 V DC
0.4 A, 24 V DC
0.8 A, 24 V DC
0.4 A, 24 V DC
Total: 25 W max.
Total: 14 W max.
Total: 25 W max.
Total: 19.6 W max.
Output terminal (service supply)
Not provided.
RUN output *2
Contact configuration: SPST-NO Switch capacity: 250 V AC, 2 A (resistive load) 120 V AC, 0.5 A (inductive load), 24 V DC, 2A (resistive load) 24 V DC, 2 A (inductive load)
Not provided.
Replacement notification function
Not provided.
With Alarm output (opencollector output) 30 V DC max., 50 mA max.
Not provided.
Insulation resistance
20 MΩ min. (at 500 V DC) between AC external and GR terminals *3
20 MΩ min. (at 500 V DC) between all external terminals and GR terminal, and between all alarm output terminals.
20MΩ 1 min. (at 250 V DC) between all alarm output terminals and GR terminal.
20 MΩ min. (at 500 V DC) between AC external and GR terminals *3
20 MΩ min. (at 500 V DC) between DC external and GR terminals *3
_ *6
Dielectric strength *4
2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals *3 Leakage current: 10 mA max.
2,300 VAC, 50/60 Hz for 1 minute between all external terminals and GR terminal and between all alarm output terminals with a leakage current of 10 mA max. x 1,000 V AC, 50/60 Hz for 1 minute between all alarm output terminals and GR terminal with a leakage current of 10 mA max.
2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals *3 Leakage current: 10 mA max.
1,000 V AC, 50/60 Hz for 1 minute between DC external and GR terminals *3 Leakage current: 10 mA max.
_ *6
1,000 V AC, 50/60 Hz for 1 minute between DC external and GR terminals *3 Leakage current: 10 mA max.
Noise immunity
2 kV on power supply line (conforming to IEC61000-4-4)
Vibration resistance
10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes (Time coefficient: 8 minutes u coefficient factor 10 = total time 80 min.) (according to JIS C0040)
Shock resistance
147 m/s2 3 times each in X, Y, and Z directions (Relay Output Unit: 100 m/s2) (according to JIS C0041)
Ambient operating temperature
0 to 55qC
Ambient operating humidity
10% to 90% (with no condensation)
10% to 90% (with no condensation) *5
10% to 90% (with no condensation)
Atmosphere
Must be free from corrosive gases.
Ambient storage temperature
_20 to 70qC (excluding battery)
_20 to 75qC *5
20 to 75qC (excluding battery)
Grounding
Less than 100 :
Enclosure
Mounted in a panel.
Weight
All models are each 5 kg max.
No comment |