1771 Digital DC Input Modules
Cat. No. | Number of Inputs | Voltage Category | Operating Voltage | Signal Delay (typical) | Off-State Current, Max. | Wiring | Backplane Current Load | Applications* | |
1771-IGD | 16 | 5V DC | TTL | TTL-compatible | <1 ms | — | 1771-WH | 130 mA | TTL interfaces, BCD interfaces encoders (A-B Bulletin 854C) |
1771-IB | 8 | 10…60V DC | sink (source load) | 10…27V | on = 12 (±7) ms | 3.0 mA | 1771-WA | 74 mA | Compatible with source switching devices, including: |
1771-IC | 8 | 42…56V | on = 15 (±7) ms | 3.7 mA | 1771-WA | 74 mA | |||
1771-IH | 8 | 24…50V | on = 15 (±7) ms | 0.7 mA | 1771-WA | 74 mA | |||
1771-IT | 8 | 12…27V | on = 0.6 (±0.2) ms | 1.3 mA | 1771-WA | 74 mA | |||
1771-IBD | 16 | 10…30V | on = 1.3 (±0.1) ms | 2.0 mA | 1771-WH | 130 mA | |||
1771-ICD | 16 | 20…60V | on = 6 (±2) ms | 1.2 mA | 1771-WH | 250 mA | |||
1771-IBN | 32 (4 sets of 8) | 10…30V | on = 6 (±2) ms | 1.7 mA | 1771-WN | 280 mA | |||
1771-IV | 8 | source (sink load) | 12…24V | on = 15 (±7) ms | 3.0 mA | 1771-WA | 74 mA | Sink DC input signal termination | |
1771-IVN | 32 (4 sets of 8) | 10…30V | on = 6 (±2) ms | 1.7 mA | 1771-WN | 280 mA | |||
1771-IQ | 8 | sink or source load | 5…30V | fast,on/off <1 ms | — | 1771-WC | 150 mA | Source or sink input signal termination time-critical applications | |
1771-IQ16 | 16 | 10…32V | 4 filter times | 2.0 mA | 1771-WN | 100 mA |
1771-IB AB PLC 8 Number of inputs Digital DC Input Module 1771 Series Original brand new
1771 Digital DC Input Modules
Cat. No.
Number of Inputs
Voltage Category
Operating Voltage
Signal Delay (typical)
Off-State Current, Max.
Wiring
ArmBackplane Current Load
Applications*
1771-IGD
16
5V DC
TTL
TTL-compatible
5.0…5.3V<1 ms
—
1771-WH
130 mA
TTL interfaces, BCD interfaces encoders (A-B Bulletin 854C)
1771-IB
8
10…60V DC
sink (source load)
10…27V
on = 12 (±7) ms
off = 20 (±7) ms3.0 mA
1771-WA
74 mA
Compatible with source switching devices, including:
•dry-contact switches
•electro-mechanical transmitters
•panel switching devices, such as pushbutton and selector switches1771-IC
8
42…56V
on = 15 (±7) ms
off = 20 (±7) ms3.7 mA
1771-WA
74 mA
1771-IH
8
24…50V
on = 15 (±7) ms
off = 15 (±7) ms0.7 mA
1771-WA
74 mA
1771-IT
8
12…27V
on = 0.6 (±0.2) ms
off = 0.6 (±0.2) ms1.3 mA
1771-WA
74 mA
1771-IBD
16
10…30V
on = 1.3 (±0.1) ms
off = 1.3 (±0.1) ms2.0 mA
1771-WH
130 mA
1771-ICD
16
20…60V
on = 6 (±2) ms
off = 20 (±1) ms1.2 mA
1771-WH
250 mA
1771-IBN
32 (4 sets of 8)
10…30V
on = 6 (±2) ms
(digital filter)
off = 6 (±2) ms1.7 mA
1771-WN
280 mA
1771-IV
8
source (sink load)
12…24V
on = 15 (±7) ms
off = 15 (±7) ms3.0 mA
1771-WA
74 mA
Sink DC input signal termination
1771-IVN
32 (4 sets of 8)
10…30V
on = 6 (±2) ms
(digital filter)
off = 6 (±2) ms1.7 mA
1771-WN
280 mA
1771-IQ
8
sink or source load
5…30V
fast,on/off <1 ms
slow,on/off = 12 ms
(-7, +14 ms)—
1771-WC
150 mA
Source or sink input signal termination time-critical applications
1771-IQ16
16
10…32V
4 filter times
0, 1, 9, and 18 ms2.0 mA
1771-WN
100 mA