PLC 2 channel weighing module DVP02LC-SL Delta NewDVP02LC-SL Delta PLC 2 channel 20-bit resolution Load Cell Module Original brand new
Introduction to DVP02LC-SL
1. Thank you for choosing Delta DVP02LC-SL load cell module. DVO02LC-SL provides 24-bit resolution applicable for 4-wire or 6-wire load cells with various eigenvalues. Therefore, the response time can be adjusted in coordination with each other according to users’ needs. On this basis, the market requirements on weight measurement can easily be met.
2. To ensure correct installation and operation of DVP02LC-SL, please read this operation manual carefully before using it. This operation manual only provides introductory information on DVP02LC-SL. For more detailed information on the theory of load cell, please refer to relevant references of literature.
3. The DVP02LC-SL load cell module is able to read/write data by using FROM/TO instructions through the DVP series PLC MPUNote
Note: The MPU (main processing unit) refers to PLC compatible with left-side extension, e.g. DVP-SV, DVP-EH2-L, DVP-SA2, DVP-SX2 series PLC.
Specifications
Rated power supply voltage/power consumption
24 VDC (-15 to +20%)/3 W
Voltage boundary
18 to 31.2 VDC
Max. current consumption
125 mA
Input signal range
+-40 mVDC
Sensibility
+5 VDC +/-10%
Internal resolution
24 bits
Communication port
RS-232, RS-485
Applicable sensor type
4-wire or 6-wire load cell
Temperature coefficient span
<=+- 50 ppm/K v. E
Temperature coefficient zero
point
<= +- 0.4 uV/K
Linearity error
<= 0.02%
Response time
2, 10, 20, 40, 80 ms × number of channels
4 measuring ranges
0 to 1, 0 to 2, 0 to 4, 0 to 6 mV/V
Max. distance for connecting
to load cell
100m
Max. current output
5 VDC × 300 mA
Permitted load cell
resistance
40 to 4,010 ?
Common mode rejection
(CMRR @50/60 Hz)
>= 100dB
Dynamic value filter
Setting range: K1 to K5
Average value filter
Setting range: K1 to K100
Isolation method
500 VAC between digital circuits and ground
500 VAC between analog circuits and ground
500 VAC between analog circuits and digital circuits
Serial connection to
DVP-PLC MPU
Connectable to the left side of the MPU, numbered from 100 to 107 according to the position of the module from the closest to the farthest to the MPU.
Operation/storage
Operation: 0 to 55°C (temperature),50 to 95% (humidity), pollution
degree 2
Storage: -25 to 70°C (temperature), 5 to 95% (humidity)
Vibration/shock immunity
International standards: IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27 (TEST Ea)