1746-ITB16 AB PLC 24VDC 16 Input Points 16 Outputs 1746 Series Original brand new

SLC 500 System Overview

The Allen-Bradley SLC 500 is a small chassis-based family of programmable controllers, discrete, analog, and specialty I/O, and peripheral devices. The SLC 500 family delivers power and flexibility with a wide range of communication configurations, features, and memory options. The RSLogix 500 ladder logic programming package provides flexible editors, point-and-click I/O configuration, and a powerful database editor, as well as diagnostic and troubleshooting tools to help you save project development time and maximize productivity.

Digital I/O Module Overview

Catalog Number

Voltage Category

I/O Points

Description

1746-ITB16

24V DC

16

Fast Response DC Sinking Input Module

General Specifications

Attribute

Value

Temperature, operating

IEC 60068-2-1 (Test Ad, Operating Cold),

IEC 60068-2-2 (Test Bd, Operating Dry Heat),

IEC 60068-2-14 (Test Nb, Operating Thermal Shock):0…60 °C (32…140 °F)

Temperature, nonoperating

IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),

IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),

IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock):

-40…85 °C (-40…185 °F)

Relative humidity

IEC 60068-2-30 (Test Db, Unpackaged Damp Heat):

5…95% without condensation

Vibration, operating

IEC 60068-2-6 (Test Fc, Operating):

1 g @ 5…2000 Hz

Vibration, nonoperating

2.5 g @ 5…2000 Hz

Shock, operating

30 g (3 pulses, 11 ms) – for all modules except relay contact

10 g (3 pulses, 11 ms) – for relay contact modules 1746-OWx and

1746-IOx combo

Shock, nonoperating

50 g, 3 pulses, 11 ms

Free fall (drop test)

Portable, 2.268 kg (5 lb) or less @ 0.762 m (30 in.), six drops

Portable, 2.268 kg (5 lb) or less @ 0.1016 m (4 in.), three flat drops

Isolation voltage

Isolation between communication circuits: 500V DC

Isolation between backplane and I/O: 1500V AC

 

  