Features
Extremely fast I/O backplane uses change-of-state (COS) connections to maximize performance (polling available in configuration mode).Module assembly mounts horizontally or vertically (no derating required) to fit your needs.Compact design lets it fit into limited panel space.Auto Device Replacement (ADR) allows OEMs to add machine features and I/O modules without making changes to the machine’s control software.Removal and Insertion Under Power (RIUP) makes it possible to replace a module while keeping the rest of the system running. Modular components install easily by sliding together; pull apart easily for maintenance and troubleshooting. No tools needed.Removable wiring system for economic system commissioning, troubleshooting, calibration, and diagnostics – 70% time and cost savings.Efficient network solutions with multiple DeviceNet interfaces, ControlNet, EtherNet/IP, and PROFIBUS DP communication adapters.Point Guard I/O is TÜV-certified for functional safety up to and including SIL CL 3 and Performance Level (e), Catagory 4.I/O Adapter and Communication Interface Modules Product SelectionSpecifications
Cat. No.
Input Voltage Range
Field Side Power Requirements
Inrush Current
Power Consumption (W) at 24V
Power Dissipation, Max.
PointBus Current (mA)
1734-PDN
11…25V DC DeviceNet specification
400 mA at 24V DC (+4% = 25V DC)
6 A for 5 ms
8.0 W
1.2 W at 25V
1300?
1734-ADNX
10…28.8V DC
400 mA at 24V DC (+20% = 28.8V DC)
6 A for 10 ms
8.0 W
2.8 W at 28.8V
1000‡
1734-ACNR
425 mA at 24V DC (+20% = 28.8V DC)
8.0 W
2.8 W at 28.8V
1000‡
1734-AENT
400 mA at 24V DC (+20% = 28.8V DC)
4.5 W
2.8 W at 28.8V
700§
1734-AENTR
24V DC at 400 mA nom
12V DC at 800 mA nom
10…28.8V DC, 1000 mA max10.4 W
6.3 W at 28.8V
800
1734-APB
400 mA at 24V DC (+20% = 28.8V DC)
8.0 W
2.8 W at 28.8V
1000‡
1300 mA at 5V DC ±5% (4.75…5.25V).
1000 mA at 5V DC ±5% (4.75…5.25V).
700 mA when input voltage < 17V DC.
I/O Adapter and Communication Interface Modules Product Selection
Cat. No.
Description
Compatible with POINT Guard I/O
Supports Expansion Power Supplies
Number of I/O Points, Max.?
DeviceNet
1734-PDN
DeviceNet Communication Interface
• Each POINT I/O module counts as a node on the main DeviceNet network.
• Total backplane current of I/O modules cannot exceed 1.3 A.Yes
No
136
1734-ADN
DeviceNet I/O Adapter
• A total of 63 POINT I/O modules can be assembled on a single DeviceNet node.No
Yes
504
1734-ADNX
DeviceNet I/O Adapter with Expansion Port
• A total of 63 POINT I/O modules can be assembled on a single DeviceNet node.
• Expansion network port allows for a DeviceNet subnet.
• Increases the reach of DeviceNet from 500 to 1500 meters.
• Increases nodes per DeviceNet scanner from 63 to more than 126 (dependent on DeviceNet scanner capacity).No
Yes
504
ControlNet
1734-ACNR
ControlNet I/O Adapter
• A total of 63 POINT I/O modules can be assembled on a single ControlNet node.
• Up to 25 direct connections and 5 rack connections are allowed.No
Yes
504
EtherNet/IP
1734-AENT
EtherNet/IP Twisted Pair Media I/O Adapter
• A total of 63 POINT I/O modules can be assembled on a single EtherNet/IP node.
• Refer to the User Manual to determine the ratings for direct and rack connections allowed.Yes
Yes
504
1734-AENTR
2-Port EtherNet/IP I/O Adapter Module
• Inlcudes 2 EtherNet/IP ports, configured as embedded switch.
• Supports star, tree, linear, and ring topologies.
• Up to 20 direct connections and 5 rack optimized connections (digital I/O only) are allowed.
• Total backplane current of I/O modules cannot exceed 0.8 A.Yes
Yes
504
PROFIBUS DP
1734-APB
PROFIBUS DP I/O Adapter
• A total of 63 POINT I/O modules can be assembled on a single PROFIBUS DP node.No
Yes
504
Using the eight-point digital I/O modules.
Point I/O with an I/O apapter and with Communication Interface Module