1734-ADN AB PLC 10-28.8VDC 63 POINT I/O modules DeviceNet 1734 Series Original brand new


Features

Extremely fast I/O backplane uses change-of-state (COS) connections to maximize performance (polling available in configuration mode).Module assembly mounts horizontally or vertically (no derating required) to fit your needs.Compact design lets it fit into limited panel space.Auto Device Replacement (ADR) allows OEMs to add machine features and I/O modules without making changes to the machine’s control software.Removal and Insertion Under Power (RIUP) makes it possible to replace a module while keeping the rest of the system running. Modular components install easily by sliding together; pull apart easily for maintenance and troubleshooting. No tools needed.Removable wiring system for economic system commissioning, troubleshooting, calibration, and diagnostics – 70% time and cost savings.Efficient network solutions with multiple DeviceNet interfaces, ControlNet, EtherNet/IP, and PROFIBUS DP communication adapters.Point Guard I/O is TÜV-certified for functional safety up to and including SIL CL 3 and Performance Level (e), Catagory 4.I/O Adapter and Communication Interface Modules Product Selection

Specifications

Cat. No.

Input Voltage Range

Field Side Power Requirements

Inrush Current

Power Consumption (W) at 24V

Power Dissipation, Max.

PointBus Current (mA)

1734-PDN

11…25V DC DeviceNet specification

400 mA at 24V DC (+4% = 25V DC)

6 A for 5 ms

8.0 W

1.2 W at 25V

1300? 

1734-ADNX

10…28.8V DC

400 mA at 24V DC (+20% = 28.8V DC)

6 A for 10 ms

8.0 W

2.8 W at 28.8V

1000‡ 

1734-ACNR

425 mA at 24V DC (+20% = 28.8V DC)

8.0 W

2.8 W at 28.8V

1000‡ 

1734-AENT

400 mA at 24V DC (+20% = 28.8V DC)

4.5 W

2.8 W at 28.8V

700§ 

1734-AENTR

24V DC at 400 mA nom
12V DC at 800 mA nom
10…28.8V DC, 1000 mA max

10.4 W

6.3 W at 28.8V

800

1734-APB

400 mA at 24V DC (+20% = 28.8V DC)

8.0 W

2.8 W at 28.8V

1000‡ 

1300 mA at 5V DC ±5% (4.75…5.25V).

1000 mA at 5V DC ±5% (4.75…5.25V).

700 mA when input voltage < 17V DC.

I/O Adapter and Communication Interface Modules Product Selection

Cat. No.

Description

Compatible with POINT Guard I/O

Supports Expansion Power Supplies

Number of I/O Points, Max.? 

DeviceNet

1734-PDN

DeviceNet Communication Interface
• Each POINT I/O module counts as a node on the main DeviceNet network.
• Total backplane current of I/O modules cannot exceed 1.3 A.

Yes

No

136

1734-ADN

DeviceNet I/O Adapter
• A total of 63 POINT I/O modules can be assembled on a single DeviceNet node.

No

Yes

504

1734-ADNX

DeviceNet I/O Adapter with Expansion Port
• A total of 63 POINT I/O modules can be assembled on a single DeviceNet node.
• Expansion network port allows for a DeviceNet subnet.
• Increases the reach of DeviceNet from 500 to 1500 meters.
• Increases nodes per DeviceNet scanner from 63 to more than 126 (dependent on DeviceNet scanner capacity).

No

Yes

504

ControlNet

1734-ACNR

ControlNet I/O Adapter
• A total of 63 POINT I/O modules can be assembled on a single ControlNet node.
• Up to 25 direct connections and 5 rack connections are allowed.

No

Yes

504

EtherNet/IP

1734-AENT

EtherNet/IP Twisted Pair Media I/O Adapter
• A total of 63 POINT I/O modules can be assembled on a single EtherNet/IP node.
• Refer to the User Manual to determine the ratings for direct and rack connections allowed.

Yes

Yes

504

1734-AENTR

2-Port EtherNet/IP I/O Adapter Module
• Inlcudes 2 EtherNet/IP ports, configured as embedded switch.
• Supports star, tree, linear, and ring topologies.
• Up to 20 direct connections and 5 rack optimized connections (digital I/O only) are allowed.
• Total backplane current of I/O modules cannot exceed 0.8 A.

Yes

Yes

504

PROFIBUS DP

1734-APB

PROFIBUS DP I/O Adapter
• A total of 63 POINT I/O modules can be assembled on a single PROFIBUS DP node.

No

Yes

504

Using the eight-point digital I/O modules.

Point I/O with an I/O apapter and with Communication Interface Module










  